    BS 5516-1-2004 Patent glazing and sloping glazing for buildings - Code of practice for design and installation of sloping and vertical patent glazing《建筑物用特制和倾斜门窗玻璃 倾斜和垂直的特制门窗玻璃的设计与.pdf

    • 资源ID:545166       资源大小:2.23MB        全文页数:68页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS 5516-1-2004 Patent glazing and sloping glazing for buildings - Code of practice for design and installation of sloping and vertical patent glazing《建筑物用特制和倾斜门窗玻璃 倾斜和垂直的特制门窗玻璃的设计与.pdf

    1、BRITISH STANDARD BS 5516-1:2004 Patent glazing and sloping glazing for buildings Part 1: Code of practice for design and installation of sloping and vertical patent glazing ICS 81.040.20; 91.060.50 BS 5516-1:2004 This British Standard was published under the authority of the Standards Policy and Str

    2、ategy Committee on 26 November 2004 BSI 26 November 2004 First published, as CP145.101, April 1951 Second edition, as CP145-1, January 1969 Third edition, as BS 5516, December 1977 Fourth edition, as BS 5516, April 1991 Fifth edition, as BS 5516-1, November 2004 The following BSI references relate t

    3、o the work on this British Standard: Committee reference B/520/5 Draft for comment 03/111701 DC ISBN 0 580 44711 1 Committees responsible for this British Standard The preparation of this British Standard was entrusted by Technical Committee B/520, Glass and glazing in building, to Subcommittee B/52

    4、0/5, Patent glazing and non-vertical glazing, upon which the following bodies were represented: Association of Building Engineers Consumer Policy Committee of BSI Council for Aluminium in Building Flat Glass Manufacturers Association Glass and Glazing Federation Institution of Structural Engineers O

    5、ffice of the Deputy Prime Minister represented by BRE Co-opted members Amendments issued since publication Amd. No. Date CommentsBS 5516-1:2004 BSI 26 November 2004 i Contents Page Committees responsible Inside front cover Foreword ii Introduction 1 1S c o p e 2 2 Normative references 2 3T e r m s a

    6、 n d d e f i n i t i o n s 4 4 Provision of information 8 5 Materials, components and finishes 10 6 Mechanical design 14 7S a f e t y 1 8 8F i r e 1 9 9 Ventilation and openings 19 10 Heat 20 11 Acoustic performance 22 12 Security 22 13 Installation 22 14 Weather resistance and performance testing 2

    7、4 15 Maintenance 26 16 Durability 28 Annex A (normative) Wind load 30 Annex B (normative) Snow load 36 Annex C (normative) Self-weight 39 Annex D (normative) Maintenance load 39 Annex E (normative) Determination of working pressures for patent glazing 40 Annex F (informative) Typical structural calc

    8、ulation for glazing bars to the requirements of BS 8118 42 Annex G (normative) Method of test for watertightness of unsealed patent glazing systems 51 Annex H (normative) Site water testing 61 Bibliography 63 Figure 1 Typical examples of patent glazing bars 4 Figure 2 Dimensional and positional tole

    9、rances of patent glazing 23 Figure A.1 Basic wind speed map (from BS 6399-2:1997) 31 Figure A.2 Topographic zones 34 Figure B.1 Basic snow load map (from BS 6399-3:1997) 38 Figure G.1 Typical specimen details 53 Figure G.2 Test pressure difference increments 56 Figure G.3 Classification exposure map

    10、 58 Table A.1 Site terrain categories 32 Table A.2 Dynamic wind pressure 33 Table A.3 Topographical factor 34 Table A.4 Combined pressure coefficients 35 Table A.5 Building factors 36 Table G.1 Watertightness classification requirements 59 Table G.2 K zfactor table 59BS 5516-1:2004 ii BSI 26 Novembe

    11、r 2004 Foreword This part of BS 5516 has been prepared by Technical Committee B/520. This part of BS 5516, together with BS 5516-2:2004, supersedes BS 5516:1991, which is withdrawn. It revises all or part of Clauses 1 to 3, 5 to 9, 10.3 to 10.5, 10.6.2, 10.6.3, 10.8, 11 to 14, 19, 20.1, 20.3, 20.4,

    12、21 to 24, 25.1, 25.2, 25.4, 25.6, 25.8, 25.9, 26 to 29 and Annex A to Annex F and Annex J to Annex K of BS 5516:1991. BS 5516:1991 has been revised and restructured to simplify its use and will be published in three parts covering the following areas: Part 1: Code of practice for design and installa

    13、tion of sloping and vertical patent glazing; Part 2: Code of practice for sloping glazing; Part 3: Special applications. Requirements for standards of workmanship for glazing have been published separately as BS 8000-7 and, therefore, this subject is not dealt with in this standard. Since the correc

    14、t selection of materials to be used in glazing for buildings depends on many factors, attention is drawn to the recommendations in the other parts of this standard. As a code of practice, this British Standard takes the form of guidance and recommendations. It should not be quoted as if it were a sp

    15、ecification and particular care should be taken to ensure that claims of compliance are not misleading. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself co

    16、nfer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 63 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.BS 5516-1:2004 BSI 26 November 2004 1 I

    17、ntroduction Patent glazing is the term applied to a self-draining and ventilated system of dry glazing that does not rely entirely for its watertightness upon external glazing seals. It consists essentially of a series of longitudinal glazing bars, i.e. patent glazing bars, and an infilling of glass

    18、 or other suitable infill material. Patent glazing bars are attached to and supported by structural members, either directly or indirectly. Patent glazing systems are described by the number of edges by which the infilling is supported. They are generally unsealed, at the interface with the building

    19、 substrate relying on flashings and/or formed weatherings for weathertightness. They differ from sloping curtain wall systems which form sealed airtight constructions. Curtain wall systems designed for vertical application might not be suitable for sloping application, unless they incorporate a slop

    20、ing application drainage facility or are face sealed to exclude water from the glazing rebates. a) Two-edge systems are those in which the infilling is fully supported by patent glazing bars on two opposite longitudinal edges only. Horizontal flashings or other weatherings are normally provided at t

    21、he top and bottom edges of single tier glazing and at junctions of glazing of more then one tier. b) Four-edge systems are those in which the infilling is fully supported by patent glazing bars on two opposite longitudinal edges and additionally on the other two edges by transom members. BS 5516-1:2

    22、004 2 BSI 26 November 2004 1 Scope This British Standard gives recommendations for the design, manufacture, installation and maintenance of sloping and vertical patent glazing systems attached to and supported by structural members of adequate strength, stiffness and stability. All recommendations a

    23、pply to flat, including faceted, patent glazing and infilling. They may also apply to curved patent glazing and infilling except for the structural design where specialist advice is needed. The patent glazing systems included in this standard comprise glazing bars of aluminium or steel, which can be

    24、 clad totally or partially clad with lead or PVC-U, for two-edge support and four-edge support systems for single and double glazing or other infill. A range of transparent and opaque infillings of glass, plastics glazing sheet materials and other infill materials are included; specific information

    25、on plastics glazing sheet materials is given in BS 5516-2:2004, Annex A. This standard covers the use of patent glazing in permanent buildings and structures, including conservatories but excludes greenhouses. Clauses that are relevant also apply to the use of patent glazing inside buildings. This s

    26、tandard does not include recommendations for the design of the supporting structure to which the patent glazing is attached. Requirements for standards of workmanship for glazing have been published separately as BS 8000-7 and, therefore, this subject is not within the scope of this standard. Since

    27、the correct selection of materials to be used in glazing for buildings depends on many factors, attention is drawn to the recommendations in the other parts of this standard. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated r

    28、eferences, only the reference cited applies. For undated references, the latest edition of the referenced document (including any amendments). BS 476-20, Fire tests on building materials and structures Part 20: Method for determination of the fire resistance of elements of construction (general prin

    29、ciples). BS 476-22, Fire tests on building materials and structures Part 22: Methods for determination of the fire resistance of non-loadbearing elements of construction. BS 1449-1, Steel plate, sheet and strip Part 1: Carbon and carbon-manganese plate, sheet and strip. BS 1473, Specification for wr

    30、ought aluminium and aluminium alloys for general engineering purposes Rivet, bolt and screw stock. BS 3382, Specification for electroplated coatings on threaded components. BS 3987, Specification for anodic oxidation coatings on wrought aluminium for external architectural applications. BS 4254, Spe

    31、cification for two-part polysulphide-based sealants. BS 4842, Specification for liquid organic coatings for application to aluminium alloy extrusions, sheet and preformed sections for external architectural purposes, and for the finish on aluminium alloy extrusions, sheet and preformed sections coat

    32、ed with liquid organic coatings. BS 4921, Specification for sherardized coatings on iron or steel. BS 5215, Specification for one-part gun grade polysulphide-based sealants. BS 5268, Structural use of timber Code of practice for permissible stress design, materials and workmanship. BS 5516-2:2004, P

    33、atent glazing and sloping glazing for buildings Part 2: Code of practice for design and installation of sloping and vertical patent glazing. BS 5889, Specification for one-part gun grade silicone-based sealants. BS 5950, Structural use of steelwork in building. BS 6180, Barriers in and about buildin

    34、gs Code of practice. BS 6262 (all parts), Code of practice for glazing for buildings.BS 5516-1:2004 BSI 26 November 2004 3 BS 6270-3, Code of practice for cleaning and surface repair of buildings Part 3: Metals (cleaning only). BS 6338, Specification for chromate conversion coatings on electroplated

    35、 zinc and cadmium coatings. (ISO 4520) BS 6399-2:1997, Loading for buildings Part 2: Code of practice for wind loads. BS 6399-3, Loading for buildings Part 3: Code of practice for imposed roof loads. BS 6496, Specification for powder organic coatings for application and stoving to aluminium alloy ex

    36、trusions, sheet and preformed sections for external architectural purposes, and for the finish on aluminium alloy extrusions, sheet and preformed sections coated with powder organic coatings. BS 6497, Specification for powder organic coatings for application and stoving to hot-dip galvanized hot-rol

    37、led steel sections and preformed steel sheet for windows and associated external architectural purposes, and for the finish on galvanized steel sections and preformed sheet coated with powder organic coatings. BS 7412, Plastics windows made from unplasticized polyvinyl chloride (PVC-U) extruded holl

    38、ow profiles Specification. BS 8118-1:1991, Structural use of aluminium Structural use of aluminium Part 1: Code of practice for design. BS EN 477, Unplasticized polyvinylchloride (PVC-U) profiles for the fabrication of windows and doors Determination of the resistance to impact of main profiles by f

    39、alling mass. BS EN 478, Unplasticized polyvinylchloride (PVC-U) profiles for the fabrication of windows and doors Appearance after exposure at 150 C Test method. BS EN 479, Unplasticized polyvinylchloride (PVC-U) profiles for the fabrication of windows and doors Determination of heat reversion. BS E

    40、N 485, Aluminium and aluminium alloys Sheet, strip and plate. BS EN 755, Aluminium and aluminium alloys Extruded rod/bar, tube and profiles. BS EN 1363-1, Fire resistance tests Part 1: General requirements. BS EN 1364-1, Fire resistance tests for non-loadbearing elements Part 1: Walls. BS EN 1364-2,

    41、 Fire resistance tests for non-loadbearing elements Part 2: Ceilings. BS EN 3506 (all parts), Mechanical properties of corrosion resistant stainless steel fasteners. BS EN 10002-1, Tensile testing of metallic materials Part 1: Method of test at ambient temperature. BS EN 10143, Continuously hot-dip

    42、metal coated steel sheet and strip Tolerances on dimensions and shape. BS EN 12056-3, Gravity drainage systems inside buildings Part 3: Roof drainage, layout and calculation. BS EN 12588, Lead and lead alloys Rolled lead sheet for building purposes. BS EN 22063, Metallic and other inorganic coatings

    43、 Thermal spraying Zinc, aluminium and their alloys. BS EN ISO 1461, Hot dip galvanized coatings on fabricated iron and steel articles Specifications and test methods.BS 5516-1:2004 4 BSI 26 November 2004 3 Terms and definitions For the purposes of this British Standard, the following terms and defin

    44、itions apply. 3.1 butt joint joint between edges of adjacent panes of infilling, usually horizontal and weathered by a came or sealant 3.2 came non-load-bearing member used to weather a horizontal butt joint in a two-edge system of patent glazing 3.3 cap profile, fitted over a patent glazing bar or

    45、pressure plate, to retain infilling and impede direct water penetration NOTE See Figure 1. Key 1W i n g 2O u t s i d e 3S t a l k 4 Glass or infill 5G l a z i n g s e a l 6 Drainage channel a) Traditional bar Figure 1 Typical examples of patent glazing bars 5 4 6 2 1 3BS 5516-1:2004 BSI 26 November

    46、2004 5 Key 1C a p 2O u t s i d e 3S t a l k 4 Glass or infill 5G l a z i n g s e a l 6 Drainage channel b) Inverted bar Figure 1 Typical examples of patent glazing bars (continued) 5 4 6 2 3 1BS 5516-1:2004 6 BSI 26 November 2004 3.4 conservatory construction which has not less than three-quarters o

    47、f the area of its roof and not less than one half of the area of its external walls made of translucent material, and which is attached to and has direct access from a building 3.5 coupled glazing two panes of infilling spaced apart in an opening, either in the same frame or glazed separately, to fo

    48、rm an unsealed cavity 3.6 drainage channel groove formed within the section profile of a glazing bar to collect and drain water to the outside of the building, either directly or indirectly NOTE See Figure 1. 3.7 fastener mechanical device for securing patent glazing to the supporting structure, or

    49、for connecting or fastening one part to another Key 1 Glass or infill 2O u t s i d e 3C a p 4G a s k e t 5B o x c) Box bar Figure 1 Typical examples of patent glazing bars (continued) 1 2 3 4 5BS 5516-1:2004 BSI 26 November 2004 7 3.8 fixing item or assembly of items which forms the attachment of patent glazing to the supporting structure 3.9 fixing bracket fitting attached to a patent glazing bar and


    注意事项

    本文(BS 5516-1-2004 Patent glazing and sloping glazing for buildings - Code of practice for design and installation of sloping and vertical patent glazing《建筑物用特制和倾斜门窗玻璃 倾斜和垂直的特制门窗玻璃的设计与.pdf)为本站会员(花仙子)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!