欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    ASTM D6693-2004(2010) 0000 Standard Test Method for Determining Tensile Properties of Nonreinforced Polyethylene and Nonreinforced Flexible Polypropylene Geomembranes《非增强聚乙烯和非增强柔性聚.pdf

    • 资源ID:523260       资源大小:90.27KB        全文页数:5页
    • 资源格式: PDF        下载积分:5000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要5000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    ASTM D6693-2004(2010) 0000 Standard Test Method for Determining Tensile Properties of Nonreinforced Polyethylene and Nonreinforced Flexible Polypropylene Geomembranes《非增强聚乙烯和非增强柔性聚.pdf

    1、Designation: D6693 04 (Reapproved 2010)Standard Test Method forDetermining Tensile Properties of NonreinforcedPolyethylene and Nonreinforced Flexible PolypropyleneGeomembranes1This standard is issued under the fixed designation D6693; the number immediately following the designation indicates the ye

    2、ar oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the tensi

    3、leproperties of nonreinforced geomembranes in the form ofstandard dumbbell-shaped test specimens when tested underdefined conditions of pretreatment, temperature, and machinespeed.1.2 This test method can be used for testing materialsthickness between 0.25 mm (0.010 in.) and 6.3 mm (0.25 in.).NOTE 1

    4、This test method is not intended to cover precise physicalprocedures. The constant rate of crosshead movement of this test lacksaccuracy from a theoretical standpoint. A wide difference may existbetween the rate of crosshead movement and the rate of strain of thespecimen indicating that the testing

    5、speeds specified may disguiseimportant effects or characteristics of these materials in the plastic state.Further, it is realized that variations in the thicknesses of test specimens,as permitted by this test method, produce variations in the surface-volumeratios of such specimens, and that these va

    6、riations may influence the testresults. Hence, where directly comparable results are desired, all samplesshould be of equal thickness. Special additional tests should be used wheremore precise physical data are needed.1.3 Test data obtained by this test method are relevant andmay be appropriate for

    7、use in engineering design with consid-eration of test conditions as compared with in-service condi-tions.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concern

    8、s, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D638 Test Method for Tensile Properties of

    9、 PlasticsD4000 Classification System for Specifying Plastic Materi-alsD4439 Terminology for GeosyntheticsD5199 Test Method for Measuring the Nominal Thicknessof GeosyntheticsD5994 Test Method for Measuring Core Thickness ofTextured GeomembraneE4 Practices for Force Verification of Testing MachinesE6

    10、91 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 DefinitionsDefinitions of terms applying to this testmethod appear in Terminology D4439.4. Significance and Use4.1 This test method is designed to produce tensile propertydata for the cont

    11、rol and specification of nonreinforced poly-ethylene and flexible nonreinforced polypropylene geomem-branes. These data are also useful for qualitative characteriza-tion and for research and development. It may be necessary tomodify this procedure for use in testing certain materials asrecommended b

    12、y the material specifications. Therefore, it isadvisable to refer to that materials specification before usingthis test method. Table 1 in Classification D4000 lists theASTM materials standards that currently exist.4.2 Tensile properties may vary with specimen preparation,test speed, and environment

    13、 of testing. Consequently, whereprecise comparative results are desired, these factors must becarefully monitored and controlled.1This test method is under the jurisdiction of ASTM Committee D35 onGeosynthetics and is the direct responsibility of Subcommittee D35.10 on Geomem-branes.Current edition

    14、approved March 1, 2010. Published April 2010. Originallyapproved in 2001. Last previous edition approved in 2004 as D696304. DOI:10.1520/D6693-04R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStanda

    15、rds volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2.1 It is realized that a material cannot be tested withoutalso testing the method of preparati

    16、on of that material. Hence,when comparative tests of materials are desired, the care mustbe exercised to ensure that all samples are prepared in exactlythe same way, unless the test is to include the effects of samplepreparation. Similarly, for referee purposes or comparisonswithin any given series

    17、of specimens, care must be taken tosecure the maximum degree of uniformity in details of prepa-ration, treatment, and handling.NOTE 2Tensile properties may provide useful data for plastics engi-neering design purposes. However, because of the high degree ofsensitivity exhibited by many plastics to r

    18、ate of straining and environ-mental conditions, data obtained by this test method cannot be consideredvalid for applications involving load-time scales or environments widelydifferent from those of this test method. In cases of such dissimilarity, noreliable estimation of the limit of usefulness can

    19、 be made for most plastics.This sensitivity to rate of straining and environment necessitates testingover a broad load-time scale and range of environmental conditions iftensile properties are to suffice for engineering design purposes.5. Apparatus5.1 Testing MachineA testing machine of the constant

    20、-rate-of-crosshead-movement type and comprising essentiallythe following:5.1.1 Fixed MemberA fixed or essentially stationarymember carrying one grip.5.1.2 Movable MemberA movable member carrying asecond grip.5.1.3 GripsGrips for holding the test specimen betweenthe fixed member and the movable membe

    21、r of the testapparatus can be either a fixed or self-aligning type.5.1.3.1 Fixed grips are rigidly attached to the fixed andmovable members of the test apparatus. Extreme care shouldbe taken when this type of grip is used to ensure that the testspecimen is inserted and clamped so that the long axis

    22、of thetest specimen coincides with the direction of pull through thecenterline of the grip assembly.5.1.3.2 Self-aligning grips are attached to the fixed andmovable members of the test apparatus. This type of gripassembly is such that they will move freely into alignment assoon as any load is applie

    23、d as long as the long axis of the testspecimen will coincide with the direction of the applied pullthrough the centerline of the grip assembly. The specimensshould be aligned as perfectly as possible with the direction ofpull so that no rotary motion will occur in the grips therebyinducing slippage;

    24、 there is a limit to the amount of misalign-ment self-aligning grips will accommodate.5.1.3.3 The test specimen shall be held in such a way thatslippage relative to the grips is prevented as much as possible.Grip surfaces that are deeply scored or serrated with a patternsimilar to those of a coarse

    25、single-cut file, serrations about2.4 mm (0.09 in.) apart and about 1.6 mm (0.06 in.) deep, havebeen found satisfactory for most thermoplastics. Finer serra-tions have been found to be more satisfactory for harderplastics, such as the thermosetting materials. The serrationsshould be kept clean and sh

    26、arp. Breaking in the grips mayoccur at times, even when deep serrations or abraded specimensurfaces are used; other techniques must be used in these cases.Other techniques that have been found useful, particularly withsmooth-faced grips, are abrading that portion of the surface ofthe specimen that w

    27、ill be in the grips, and interposing thinpieces of abrasive cloth, abrasive paper, plastic, or rubber-coated fabric, commonly called hospital sheeting, between thespecimen and the grip surface. No. 80 double-sided abrasivepaper has been found effective in many cases. An open-meshfabric, in which the

    28、 threads are coated with abrasive, has alsobeen effective. Reducing the cross-sectional area of the speci-men may also be effective. The use of special types of grips issometimes necessary to eliminate slippage and breakage in thegrips.5.1.4 Drive MechanismA drive mechanism for impartingto the movab

    29、le member a uniform, controlled velocity withrespect to the stationary member, with this velocity to beregulated as specified in Section 9.5.1.5 Load IndicatorA suitable load-indicating mecha-nism capable of showing the total tensile load carried by thetest specimen when held by the grips. This mech

    30、anism shall beessentially free of inertia lag at the specified rate of testing andshall indicate the load with an accuracy of 61 % of theindicated value, or better. The accuracy of the testing machineshall be verified in accordance with Practices E4.NOTE 3Experience has shown that many testing machi

    31、nes now in useare incapable of maintaining accuracy for as long as the periods betweeninspection recommended in Practices E4. Hence, it is recommended thateach machine be studied individually and verified as often as may befound necessary. It frequently will be necessary to perform this functiondail

    32、y.6. Test Specimens6.1 Sheet, Plate, and Molded Plastics:6.1.1 The test specimens shall conform to the dimensionsshown in Fig. 1. This specimen geometry was adopted fromTest Method D638 and is therefore equivalent to Type IV ofsaid standard.6.1.2 Test specimens shall be prepared by die cutting fromm

    33、aterials in sheet, plate, slab, or similar form.6.2 All surfaces of the specimen shall be free of visibleflaws, scratches, or imperfections. If the specimen exhibitssuch markings, it should be discarded and replaced. If theseflaws or imperfections are present in the new specimen, the dieshould be in

    34、spected for flaws.NOTE 4Negative effects from imperfections on the edge of thespecimens can severely impact the results of this test and should thereforebe carefully monitored. In cases of dispute over the results, inspection ofthe die and specimen preparation should take place.7. Conditioning7.1 Co

    35、nditioningSpecimens should be tested once thematerial has reached temperature equilibrium. The time re-quired to reach a temperature equilibrium may vary accordingto the manufacturing process, material type, and materialthickness.7.2 Test ConditionsConduct tests in the Standard Labora-tory Atmospher

    36、e of 21 6 2C (69.8 6 3.6F) unless otherwisespecified in the test methods.NOTE 5A humidity requirement has intentionally been left out of thetest conditions due to the fact that polyolefins are not significantly affectedD6693 04 (2010)2by large fluctuations in humidity thereby making such a restricti

    37、onunnecessary.NOTE 6The tensile properties of some plastics change rapidly withsmall changes in temperature. Since heat may be generated as a result ofstraining the specimen at high rates, conduct tests without forced coolingto ensure uniformity of test conditions. Measure the temperature in theredu

    38、ced section of the specimen and record it for materials whereself-heating is suspected.8. Number of Test Specimens8.1 Test at least five specimens for each sample in the caseof isotropic materials.8.2 Test ten specimens, five normal to and five parallel withthe principle axis of anisotropy, for each

    39、 sample in the case ofanisotropic materials.8.3 Discard specimens that break at some obvious flaw andprepare new specimens for retest, unless such flaws constitutea variable to be studied.9. Speed of Testing9.1 Speed of testing shall be the relative rate of motion ofthe grips or test fixtures during

    40、 the test. The rate of motion ofthe driven grip or fixture when the test apparatus is running idlemay be used, if it can be shown that the resulting speed oftesting is within the limits of variation allowed.9.2 The test speed shall be 50 mm/min (2 in./min) forpolyethylene geomembranes and 500 mm/min

    41、 (20 in./min) fornonreinforced flexible polypropylene geomembranes.NOTE 7Some nonreinforced polyethylene materials approaching butless than a density of 0.940 g/cc exhibit less variation when tested at 2 ipmrather than 20 ipm. If a test speed other than that indicated in 9.2 is used,this modificatio

    42、n should be noted in the report.10. Procedure10.1 Measure the width and thickness of rigid flat speci-mens (Fig. 1) in accordance with Test Method D5199 forsmooth geomembranes and Test Method D5994 for textured(non-smooth) geomembranes.10.2 Place the specimen in the grips of the test apparatus,takin

    43、g care to align the long axis of the specimen and the gripswith an imaginary line joining the points of attachment of thegrips to the machine. The distance between the ends of thegripping surfaces, when using flat specimens, shall be asindicated in Fig. 1. Tighten the grips evenly and firmly to thed

    44、egree necessary to prevent slippage of the specimen duringthe test, but not to the point where the specimen would becrushed.10.3 Set the speed of testing at the proper rate in accordancewith Section 9, and start the machine.Specimen Dimensions for Type IV Dog Bone of Thickness, T, mm (in.)Descriptio

    45、n Dimension, mm (in.) Tolerances, mm (in.)Wwidth of narrow section 6 (0.25) 60.5 (60.02)Llength of narrow section 33 (1.30) 60.5 (60.02)GLYgauge length for yield 33 (1.30) 60.5 (60.02)GLBgauge length for break 50 (2.0) 60.5 (60.02)WOwidth overall 19 (0.75) 66.4 (60.25)LOlength overall 115 (4.5) No m

    46、ax, No minGgauge length 25 (1.00) 60.5 (60.02)Ddistance between grips 65 (2.5) 60.13 (60.005)Rradius of fillet 14 (0.56) 61(60.04)ROouter radius 25 (1.00) 61(60.04)FIG. 1 Type IV Dog Bone SpecimenD6693 04 (2010)310.4 Record the load-extension curve of the specimen.10.5 Record the load and extension

    47、at the yield point (if oneexists) and the load and extension at the moment of rupture(break point).11. Calculation11.1 Tensile Yield StrengthCalculate the load correspond-ing to the yield point in newtons (or pounds-force). Divide thatload by the original minimum width of the specimen in metres(or i

    48、nches). Express the result in newtons per millimetre (orpounds-force per inch) and report it to three significant figuresas tensile yield strength.11.2 Tensile Break StrengthCalculate the load corre-sponding to the point of rupture (break) in newtons (orpounds-force). Divide that load by the origina

    49、l minimum widthof the specimen in metres (or inches). Express the result innewtons per millimetre (or pounds-force per inch) and report itto three significant figures as tensile break strength.11.3 Percent Yield ElongationCalculate percent elonga-tion at the yield point by reading the extension (change ingauge length) at the moment the applicable load is reached.Divide that extension by the gauge length for yield listed inFig. 1 (GLY) and multiply by 100. Report percent yieldelongation to the nearest 1%.11.4 Percent Break ElongationCalculate percent


    注意事项

    本文(ASTM D6693-2004(2010) 0000 Standard Test Method for Determining Tensile Properties of Nonreinforced Polyethylene and Nonreinforced Flexible Polypropylene Geomembranes《非增强聚乙烯和非增强柔性聚.pdf)为本站会员(eventdump275)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开