欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    ASME TDP-1-1998 Recommended Practices for the Prevention of Water Damage to Steam Tables Used For Electric Power Gen《发电站用蒸汽表防水损害的推荐实施规程》.pdf

    • 资源ID:456992       资源大小:1.38MB        全文页数:37页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    ASME TDP-1-1998 Recommended Practices for the Prevention of Water Damage to Steam Tables Used For Electric Power Gen《发电站用蒸汽表防水损害的推荐实施规程》.pdf

    1、Copyright ASME International Provided by IHS under license with ASMENot for ResaleNo reproduction or networking permitted without license from IHS-,-The American Society of Mechanical Engineers AN AMERICAN NATIONAL STANDARD RECOPi1MENDED PRACTIIES FOR THE PREVENTION OF WATER DAMAEE TO STEAM TURBINES

    2、 USED FOR ELECTRII: POWER GENERATION ASME TDP-1-1998 (Revision 01 ANSVASME TDP-1-1185) FOSSIL FUELED PLANTS Copyright ASME International Provided by IHS under license with ASMENot for ResaleNo reproduction or networking permitted without license from IHS-,-Date of Issuance: January 29, 1999 This Sta

    3、ndard will be revised when the Society approves the issuance of a new edition. There will be no addenda or written interpretations of the requirements of this Standard issued to this edition. ASME is the registered trademark of The American Society of Mechanical Engineers. This code or standard was

    4、developed under procedures accredited as meeting the criteria for American National Standards. The Standards Committee that approved the code or standard was balanced to assure that individuals from competent and concerned interests have had an opportunity to participate. The proposed code or standa

    5、rd was made available for public review and comment that provides an opportunity for additional public input from industry, academia, regulatory agencies, and the public-at-large. ASME does not “approve,“ “rate,“ or “endorse“ any item, construction, proprietary device, or activity. ASME does not tak

    6、e any position with respect to the validity of any patent rights asserted in connection with any items mentioned in this document, and does not undertake to insure anyone utilizing a standard against liability for infringement of any applicable Letters Patent, nor assumes any such liability. Users o

    7、f a code or standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, is entirely their own responsibility. Participation by federal agency representatives) or persons) affiliated with industry is not to be interpreted a

    8、s government or industry endorsement of this code or standard. ASME accepts responsibility foronlythose interpretations issued in accordance with governing ASME procedures and policies which precludes the issuance of interpretations by individual volunteers. No part of this document may be reproduce

    9、d in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher. The American Society of Mechanical Engineers Three Park Avenue, New York, NY 10016-5990 Copyright Q 1999 by THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS All Rights Reserved Printed i

    10、n U.S.A. Copyright ASME International Provided by IHS under license with ASMENot for ResaleNo reproduction or networking permitted without license from IHS-,-FOREWORD (This Foreword is not a part of ASME TDP-1-1998) A substantial increase in the number of reported occurrences of steam turbine damage

    11、 by water induction precipitated design recommendations from the two major domestic turbine manufacturers as an attempt to reduce such incidents. Concurrently, utilities and designers began formulating their own design criteria because of the economic need to keep the generating units in service. Re

    12、alizing the common need for a uniform set of design criteria to alleviate this problem, an ASME Standards Committee was formed, consisting of representatives of utilities, equipment manufacturers, and design consultants, to develop recommended practices for use in the electric generating industry. T

    13、his Standard, resulting from the work and deliberation of the Turbine Water Damage Prevention Committee, was approved as a standard of The American Society of Mechanical Engineers by the ASME Standardization Committee and the ASME Policy Board, Codes and Standards on July 26, 1972. In 1979, the Comm

    14、ittee proposed a revision to this ASME Standard to include information on condenser steam and water dumps, direct contact feedwater heaters, and steam generators. This proposed revision was approved by the ASME Standardization Committee on April 25, 1980. The last revision was approved as an America

    15、n National Standard on September 13, 1985. In 1994 the ASME Board on Standardization approved the disbandment of the Committee on Turbine Water Damage Prevention, and the withdrawal of the standard TDP-1. This was due to a perceived lack of interesduse by the industry. Subsequent interest from users

    16、 and potential users for TDP-1 convinced ASME to reconstitute the Committee under the Board on Pressure Technology Codes and Standards in June of 1997. The current document was approved as an American National Standard on June 17, 1998. iii Copyright ASME International Provided by IHS under license

    17、with ASMENot for ResaleNo reproduction or networking permitted without license from IHS-,-ASME STANDARDS COMMITTEE TWDP Turbine Water Damage Prevention (The following is the roster of the Committee at the time of approval of this Standard.) OFFICERS R. G. Narula, Chair L. A. Kielasa, Vice Chair A. J

    18、. Roby. Secretary COMMITTEE PERSONNEL J. C. Boyle, Stone reheat steam systems, piping, and drains; reheat attemperating system; turbine extraction systems, piping, and drains; feedwater heaters, piping, and drains; turbine drain system; turbine steam seal system, piping, and drains; main steam attem

    19、perator sprays; start-up systems; condenser steam and water dumps. Any connection to the turbine is a potential source of water either by induction from external equipment or by accumulation of condensed steam. The sources treated specifically are those that have been found to be most frequently inv

    20、olved. 2 CRITERIA 2.1 Recommendations Design, control, and operation of all systems that have a potential for allowing water to enter the turbine should prevent any unusual accumulations. However, since malfunctions do occur, the recommendations for preventing turbine damage due to water induction i

    21、n- clude one or more of the following where appropriate: (a) detection of the presence of water either in the turbine or, preferably, external to the turbine before the water has caused damage; (b) isolation of the water by manual or, preferably, automatic means after it has been detected; (c) dispo

    22、sal of the water by either manual or, prefera- bly, automatic means after it has been detected. 2.2 Failure Where experience has shown a source of water is particularly hazardous, no single failure of equipment should result in water entering the turbine. The failure mode of the various devices used

    23、 to prevent water induction should be considered so that a single failure of the signals (loss of air or electrical signal) will not cause water to enter the turbine. 3 DESIGN RECOMMENDATIONS This Section outlines specific recommendations for the design of the systems listed. These recommendations a

    24、re intended to represent a conservative design for protection from water induction. There is no intention to supersede any existing codes or governmental regula- tions. 3.1 Steam Generators 3.1.1 It is the responsibility of the plant designers to review and understand the design features of the stea

    25、m generator and of the user to adhere to the operating procedures of the steam generator manufacturer as a precaution against water induction. The majority of the incidents of turbine water damage caused by water entering the turbine from the steam system have oc- curred during start-up or shutdown

    26、of a unit. The steam generator manufacturers design and operating recommendations should include the required protection to prevent the induction of water into the main steam piping. Such areas as superheater attemperators, boiler start-up systems, high drum levels, and undrained super- heaters are

    27、some potential sources of water. 3.1.2 Experience has shown that once-through flow units, because of their start-up system, offer a greater potential for water induction through the main steam system during start-up and shutdown operating modes Copyright ASME International Provided by IHS under lice

    28、nse with ASMENot for ResaleNo reproduction or networking permitted without license from IHS-,-ASME TDP-1-1998 PREVENTION OF WATER DAMAGE TO STEAM TURBINES USED FOR ELECTRIC POWER GENERATION than do drum type steam generators. It is recommended that the start-up system on once-through units be de- si

    29、gned so that no single failure of equipment can result in water entering the main steam line. Therefore, two of the following independent means of automatically preventing water from entering the main steam lines from the start-up system should be provided: (U) the automatic opening of the drain sys

    30、tem to the condenser from the start-up system flash tank or separator on detection of high level; (b) automatic closing of the shutoff valve in the line from the start-up system to the main steam system on detection of high-hi level in the flash tank or separator; (c) automatic shutoff of all source

    31、s of water entering the start-up system by either tripping all feed pumps or closing a shutoff valve on detection of high-hi level in the flash tank or separator. Typical systems are shown in Figs. I and 2. 3.1.2.1 Figure 1 showsa primary drain line from the flash tank or separator with its associat

    32、ed level sensor and an independent automatically operated shutoff valve between the flash tank and the main steam system. The shutoff valve will be actuated by a high-hi level from an independent level signal. The drain line valve and the shutoff valve should have indicators in the control room for

    33、the open and closed positions. 3.1.2.2 Figure 2 shows a primary drain line from the flash tank or separator with its associated level sensor and an independent trip signal to the feedwater supply source. The trip signal will be actuated by a high-hi level from an independent level signal. The drain

    34、line valve and feedwater shutoff valve (if used) should have indicators in the control room for the open and closed positions. 3.1.3 It is recommended that start-up systems on other than once-through units (such as drum type) be designed so that no single failure of equipment can result in water ent

    35、ering the main steam line. The method of accomplishing this should be as determined by the designer. 3.2 Superheat Attemperator 3.2.1 Spray water injected in the steam generator ahead of the finai superheat section is a means to control steam temperature at the outlet of the superheater. These spray

    36、s are generally not effective in controlling final superheat steam temperature at low loads or during turbine rolling. The opportunity exists for water to accumulate in the pendant elements of the superheater during low load operation from either condensation or overspraying. Units which have to ope

    37、rate for extended periods of time with the spray header system charged to full pump discharge pressure (e.g., during start-up and shut-down conditions) are subject to possible leakage of the spray valves. Such leakage can result in water accumulating in the pendant superheater sections and may even

    38、flow over into the main steam system. When steam flow is increased, this accumulation of water can be injected into the turbine. 3.2.2 A power-operated block valve should be installed in series with the attemperator spray control valve. This valve provides tight shutoff to prevent water leakage past

    39、 the spray control valve and provides a backup in the event that the spray control valve fails to close when required (see Fig. 3). The spray control and block valves constitute a double line of defense against the inadvertent introduction of spray water into the main steam system. 3.2.3 The control

    40、 system should automatically close and override all manual and automatic setting of the superheat spray control and block valves when the master fuel trip actuates or the turbine trips. 3.2.4 The block valve should be automatically closed when the unit is operated below a predetermined load and, sim

    41、ultaneously, the control valve is closed. Superheat spray should not be released for automatic control at loads where it can be determined that it is relatively ineffective in reducing final superheater temperature. The loads used should be in accordance with the boiler manufacturers recommendations

    42、. Man- ual control of spray below the predetermined load should only be used with close operator supervision. Manual control must not prevent the automatic protec- tion features specified in para. 3.2.3 from operating in the event the master fuel trip actuates or the turbine trips. 3.2.5 The control

    43、 system. for opening the spray control valve should be designed to prevent the sudden injection of large quantities of water. 3.2.6 A bypass valve around the spray control valves should be power-operated and actuated to close when the block valve is closed. If a manual bypass is used, a second power

    44、-operated block valve should be provided to give a second line of defense. 2 Copyright ASME International Provided by IHS under license with ASMENot for ResaleNo reproduction or networking permitted without license from IHS-,-PREVENTION OF WATER DAMAGE TO STEAM TURBINES USED FOR ELECTRIC POWER GENER

    45、ATION ASME TDP-1-1998 FIG. 1 TYPICAL FLASH TANK/SEPARATORS ARRANGEMENT 3.2.7 A bypass of a block valve should not be should not be considered as devices which will prevent water induction into the turbine from the main steam line. provided under any circumstances. 3.3 Main Steam Piping The procedure

    46、 recommended in this Section is to prevent the accumulation of water in the main steam piping. 3.3.1 Because of the lack of detection instrumenta- tion that will close the turbine stop valves in time to prevent damage when the turbine is in operation, there are no recommendations included pertaining

    47、 to the prevention of damage by water passing through the main steam piping and into the turbine. If such devices are developed and marketed, consideration should be given to include this instrumentation. Turbine valves 3.3.2 A drain should be installed at each low point in the main steam piping fro

    48、m the boiler outlet to the connection on the turbine stop valve. When reviewing the location of low points, consideration should be given to the position of the piping in both the cold and hot position. Where there is no specific low point (where there are long runs of horizontal piping), install a

    49、low point drain at the turbine end of this Section. If the main steam line is split into more than one branch going into the turbine, each of these branches as well as the main header should be reviewed for low points. In addition, a connection should be located 3 Copyright ASME International Provided by IHS under license with ASMENot for ResaleNo reproduction or networking permitted without license from IHS-,-ASME TDP-1-1998 PREVENTION OF WATER DAMAGE TO ST