    ASHRAE OR-05-15-1-2005 Field Evaluation of Ventilation and Control of Diesel Exhaust in Enclosed Locomotive Facilities《在密封的机车设施RP-1191里的 通风及柴油车尾气控制实地评估》.pdf

    • 资源ID:455612       资源大小:1,010.31KB        全文页数:11页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    ASHRAE OR-05-15-1-2005 Field Evaluation of Ventilation and Control of Diesel Exhaust in Enclosed Locomotive Facilities《在密封的机车设施RP-1191里的 通风及柴油车尾气控制实地评估》.pdf

    1、OR-05-15-1 (RP-1191) Field Evaluation of Ventilation and Control of Diesel Exhaust in Enclosed Locomotive Amy Musser, PhD, PE Associate Member ASHRAE ABSTRACT This paper summarizes the results ofjeld measurements that were conducted in four operating diesel locomotive shops. Thephysicalgeometry and

    2、ventilation system design are docu- mented for each shop, and their usage is described. Measure- ments taken over a four-day period at each location are discussed, and typical data are presented. When possible, average contaminant concentrations for similar operating events are also analyzed togethe

    3、r to provide a more complete assessment of ventilation system operation. Finally, qualita- tive observations gathered during thejeld study that may be useful to designers are discussed. These include insights on locomotive position within the shop, control issues, and the importance of temperature i

    4、n certain types of design. INTRODUCTION Currently available design guidance for ventilation of enclosed locomotive facilities has been developed based on practical experience. However, little research exists to validate or invalidate the effectiveness of these ventilation quantities for removal of d

    5、iesel exhaust. Furthermore, there is little inde- pendent published information that surveys current practice and reports routine operating experiences. This work describes field measurements that were conducted in four shops located in the United States under normal operating conditions. There were

    6、 several goals of this study. First, the design of each ventilation system was docu- mented and described. Second, contaminant measurements were collected to compare and evaluate the various systems and also to provide validation data that can be used to develop a computational model. Also, addition

    7、al information was collected while visiting the shops that may be useful to design- Faci I it es Matthew Radik Student Member ASHRAE ers in planning future systems. The final goal of this effort, combined with future CFD modeling, is to develop handbook appropriate material to guide the design proce

    8、ss for these facilities. Several sources provide design and operations guidance relevant to ventilation of railroad facilities. The ventilation rate procedure of ASHRAE Standard 62-2001, Gntilation for Acceptable Indoor Air Quality, specifies 1.5 cfinlft2 (7.5 LIS per m2) to maintain acceptable indo

    9、or air qualiy in auto repair rooms, which is the closest listed occupancy (ASHRAE 2001). However, locomotive facilities tend to have high ceil- ings and larger volumes, so the 1999 ASHME ffandbook- Applications recommends that a volumetric model instead be used to calculate the design ventilation (A

    10、SHRAE 1999). Both the ASHRAE Handbook-Applications and the Ameri- can Railway Engineering and Maintenance-of-Way Associa- tion (AREMA) Manual for Railway Engineering suggest 6 air changes per hour when dilution ventilation is used (AREMA 2001). These values provide a benchmark for comparing the syst

    11、ems analyzed here. FIELD MEASUREMENTS Test Protocols The test protocol implemented at the shops included oper- ations monitoring, contaminant, and temperature arrays inside the shop, ventilation assessment, and weather monitoring. Because the purpose of the measurements was to characterize the respo

    12、nse of the ventilation system to locomotive operation, contaminant and temperature arrays in each shop were set up near tracks that experienced the most locomotive movement. In some cases, it was possible to leave the arrays in one loca- tion for several hours each day. In shops that experienced les

    13、s Amy Musser is a partner at Vandemusser Design, LLC, Asheville, NC. Matthew Radik is a student at the University of Nebraska, Omaha, Neb. O2005 ASHRAE. 1015 traffic, it was necessary to move the arrays based on the planned daily schedule. During the times when instruments were installed, all locomo

    14、tive movement and operation were recorded. This was done not just for the track adjacent to the instrument array, but for all tracks in the shop. Vertical contaminant and temperature arrays were set up inside the shop to obtain profiles that could be used for vali- dation of a computational model. I

    15、n most cases the array consisted of three sets of sensors that were either hung from the ceiling structure or mounted on a telescoping pole. These sensors were capable of collecting time series data for up to eight hours at a time. In all of the shops, electrochemical sensors capable of measuring ca

    16、rbon monoxide, nitric oxide, and nitrogen diox- ide were installed. Manufacturer information for the carbon monoxide sensor states a range of 0-500 ppm, a resolution of 1 ppm, a cross-reactivity without filtering of 3 ppm to 35 ppmNO, and-1 ppm to 5 ppmN0,. The nitric oxide sensor has a range of 0-2

    17、50 ppm, a resolution of 1 ppm, no cross-reac- tivity to 300 ppm CO, and 1.5 ppm cross-reactivity to 5 ppm NO,. The nitrogen dioxide sensor has a range of 0-30 ppm, a resolution of O. 1 ppm, a cross-reactivity of 15 ppm to 300 ppm CO, and no cross reactivity to 35 ppm NO. The temperature sensors have

    18、 a range of 4OF to 158F (-20C to 70C). They have a resolution of O.8“F at 68F (0.4“C at 20C) and about 1.2“F at 140F (0.7“C at 60C). At one of the sites, carbon dioxide sensors were also installed. These sensors have a range of 0-4000 ppm when used with a data logger and a resolution of 50 ppm. They

    19、 were not deployed at the other sites because the recorded variation in CO, that accompanied locomotive operation was not much larger than the normal fluctuations observed throughout the day. Therefore, they were not useful as an indicator of loco- motive operation. Mechanical flow rates were verifi

    20、ed in a number of ways, depending primarily on equipment accessibility. Manufac- turer ratings were taken fi-om drawings and nameplate infor- mation. When possible, flow rates were verified by pitot tube duct traverse or traverse-type measurements at air outlets. Although the latter method is not a

    21、particularly accurate Site la lb 2 method of determining airflow (order *20%), it does provide a means of verifiing the rated equipment flow rates. Outdoor wind speed, temperature, and relative humidity were recorded using a weather station mounted on the roof of each shop. Due to some lapses in our

    22、 data recording device, hourly average weather data recorded at nearby airports were also obtained from a weather service and used when needed to supplement the collected data. These data were primarily collected to assist in developing computational models of the facilities. Shop Area Ceiling Heigh

    23、t Exhaust Airflow Air Change Location (ftY Volume (ft?) Ventilation System Rate (cfm) Rate (hr-) Chicago 12,800 42 537,600 General exhaust 60,000 6.7 Chicago 12,800 42 537,600 General exhaust 72,000 - 102,000 8 - 1 1.3 New Orleans 21,600 19.5 and 34.5 543,000 Gcncral exhaust 5 19,000 57 Test Schedul

    24、e The four sites studied were locomotive repair shops located throughout the United States. Pilot tests were conducted at site 1 for two days in December 200 1. A second visit of three days duration was then made to this location in March 2002. Because of a calibration problem that was later discove

    25、red, the nitrogen dioxide concentration data collected at this site are unreliable and are not presented here. The protocol for the remaining tests allowed for four days at each site. The first day was reserved for setup and planning, and the remaining three days were used for data collection. A tri

    26、p to site 2 was completed in May 2002, and a trip to site 3 took place in June 2002. Site 4 was monitored in July 2002. 3a 3b 4 Test Sites A brief description of each site and its ventilation system follows. These data are based on drawings, when available, as- built conditions verified on the site

    27、visits, manufacturer infor- mation, and ventilation system measurements. Table 1 summarizes shop characteristics and exhaust volumes for all of the sites. Site i: This shop is located in Chicago. The facility is actually made up of two connected structures. The first, site la, is used for fueling an

    28、d washing locomotives. The second, site lb, is used for daily service and repair. The two structures are oriented such that locomotives first pull in to the fueling facility from the south, move forward through it into the repair Los Angeles 20,400 42 (avg.) 855,400 Natural and general 180,000 12.6

    29、Los Angeles 1 1,000 37 (avg.) 406,000 Natural and hoods 40,000 5.9 Rensselaer, NY 64,000 39 (avg.) 2,490,000 General exhaust and 320,000 - 371,000 7.7-8.9 heating Table 1. Summary of Shop Characteristics * Reported ceiling heights are rail to ceiling, and do not account for solid platforms. 1016 ASH

    30、RAE Transactions: Symposia Exhaust fan Exhaust fan I I Track 3 Treck 2 Track 1 Section View A-A Figure 1 Site 1 section viewsewice and repair shop. facility, and exit to the north. Both of these facilities are heated in the winter. A section view of the service and repair facility is shown in Figure

    31、 I. The fueling facility shares the same phys- ical arrangement but has a different ventilation system. The fueling facility, site 1 a, is heated and ventilated using three roof-mounted heat recovery units that operate year- ment. Locomotives can and do idle at all positions located on the tracks, a

    32、nd the ventilation system does not assume a loco- motive position. However, the locations of servicing equip- ment, such as the fueling tanks, do create patterns of movement and would allow the more common standing loca- tions to be identified. round for ventilation. Supply ducts are mounted vertica

    33、lly on the exterior walls, and air is supplied near the occupied zone. Air is removed at the ceiling level. These units each supply approximately 20,000 cfm (9,438 L/s) of outdoor air for venti- lation. The exterior doors on the south end of this shop remain open year-round. During the winter months

    34、, an air curtain is used to reduce infiltration from outdoors. Site 1 b, the service and repair shop, is heated by three air- handling units that provide 30,000 cfm (14,157 L/s) each of total supply air via ducts mounted overhead. These units provide approximately 10,000 cfin (4,7 19 L/s) of outdoor

    35、 air each, and they are operated only during the heating season. This shop also makes use of four large exhaust fans, which Site 2: This shop, shown in Figure 2, is located in the hot and humid climate of New Orleans. It contains four tracks, each of which can accommodate two locomotives indoors. Tr

    36、acks 1 and 4 are primarily used for extensive repairs and rebuilds. Track 2 is usually used for 90-day inspections and other repairs that require one to three days to complete. Track 3 is most often used for routine maintenance activities, which usually require about an hour. Often, locomotives are

    37、running on Track 3 for that duration. Therefore, measurement arrays at this site were usually deployed adjacent to Track 3. The arrays were moved to Track 2 for a few short periods when locomo- tive movement was planned on that track. - operate continuously at approximately 18,000 cfm (8,494 L/s) ea

    38、ch. Since our measurements were conducted during the heating season, this shop was operating at the higher air change rate during our tests. Both shops contain three tracks. These shops are heavily utilized, and ali tracks experience frequent locomotive move- Locomotives are moved into the shop thro

    39、ugh four large doors on the east end of the building that remain open. Loco- motives on Track 4 can be pulled through and out the west side of the building, but locomotives on the other tracks must be backed out of the east end doors. One notable aspect of loco- motive operation in this shop is that

    40、 locomotives are almost ASHRAE Transactions: Symposia 1017 Exhausi Fan Typical insirumeni Location Section View A-A Figure 2 Site 2 section view always pulled completely forward, and are therefore parked in the same location most of the time. This shop has many openings for natural ventilation. In a

    41、ddition to the four large open doors on the east side, there are rows of windows located at a height of about 10 ft (3 m) from the ground on the north and south walls. The shop is mechan- ically ventilated using a general exhaust system that utilizes 23 roof-mounted exhaust hoods at approximately 22

    42、,500 cfm (10,618 L/s) each. These are located above the four tracks. Personnel in the shop are able to manually start and stop these exhaust fans, but they remained on almost constantly during our visit. The only reason identified for turning them off was that they generate a moderate amount of nois

    43、e, but since they also make a significant contribution to keeping the shop cool in this hot climate, they tended to remain on. This may be somewhat less likely to occur in the winter months. All fans in this shop are normally switched on and off together. However, since they are installed with expos

    44、ed belts, fan failures are relatively common. The large number of fans, therefore, helps to maintain high exhaust flow rates even when some ofthe fans may not be operational. Since repairs had been performed just prior to our visit, all ofthe fans were operating during our tests. Site 3: This shop i

    45、s located in Los Angeles, which expe- riences warm, dry weather. Unlike all of the other shops, which operate on a 24/7 basis, this shop does not perform daily service and therefore operates on a single daytime shift. It is composed of two areas, connected by a large, open wall, as shown in Figure 3

    46、. The larger section, referred to here as site 3a, houses two tracks (3 and 4) and an elevated, enclosed office. The smaller section, site 3b, contains two additional tracks (i and 2). The tracks are oriented in the north-south direction, so that locomotives can enter from either end of the shop and

    47、 exit at the opposite end. The two shops are used and ventilated differently. The larger section, referred to here as site 3a, has a higher roof and has natural ventilation openings along the roofline and a general exhaust system. This shop has a peaked roof, with 4 ft (1.2 m) high natural ventilati

    48、on openings at the top of the wall that run the length of the building on both sides. Six 30,000 cfm (14,157 L/s) exhaust fans are mounted at the roof level, spaced evenly along its length. The smaller shop, site 3b, is connected to the east side of the larger shop and has most of its remaining thre

    49、e sides open to the outdoors. Large exhaust hoods are installed over each of the tracks. The hood configuration consists of a 90 ft (27 m) length of duct, with anarrow slot opening with 1.5 in. (38 mm) width, through which 20,000 cfm (9,438 L/s) is drawn. Flex- ible curtains hang from either side ofthe duct to guide the loco- motive exhaust into the hood. Site 3b is typically used for inspections and other rela- tively quick turnaround work. Operation is limited to idling and low throttle speeds when moving in and out. It was orig- inally intended that this area be used for proc


    注意事项

    本文(ASHRAE OR-05-15-1-2005 Field Evaluation of Ventilation and Control of Diesel Exhaust in Enclosed Locomotive Facilities《在密封的机车设施RP-1191里的 通风及柴油车尾气控制实地评估》.pdf)为本站会员(amazingpat195)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开