    ASHRAE 62 1 USERS MANUAL ERTA-2011 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY.pdf

    • 资源ID:450355       资源大小:94.64KB        全文页数:2页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    ASHRAE 62 1 USERS MANUAL ERTA-2011 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY.pdf

    1、 Page 1 of 2 2011 ASHRAE. All rights reserved. ERRATA SHEET FOR THE USERS MANUAL TO ANSI/ASHRAE STANDARD 62.1-2010 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY February 28, 2011 The corrections listed in this errata sheet apply to all copies of ANSI/ASHRAE Standard 62.1-2007 Users Manual. The first

    2、 printing is identified on the outside back cover as “ISBN 978-1-933742-98-4 Product Code: 90159 1/11”. NOTICE: ASHRAE now has a list server for Standing Standards Project Committee 62.1 (SSPC 62.1). Interested parties can now subscribe and unsubscribe to the list server and be automatically notifie

    3、d via e-mail when activities and information related to the Standard is available. To sign up for the list server please visit Standards List Servers on the Standards and Codes section of the ASHRAE website at http:/www.ashrae.org/publications/detail/15620. Page Erratum 69 Section 6 Procedures. Repl

    4、ace Page 69 of the users manual with the attached page. The published users manual has Page 37 where Page 69 should be. Note that Page 68 has been intentionally left blank. U s e r s M a n u a l f o r A N S I / A S H R A E S t a n d a r d 6 2 . 1 - 2 0 1 0 P a g e 6 9 6. Procedures General (6.1) Sec

    5、tion 6 of Standard 62.1 establishes procedures for determining ventilation parameters for mechanical and natural ventilation systems. Because these parameters form the foundation of the ventilation system design, this section is generally considered one of the most important sections of the standard

    6、 and is the section most commonly referenced in building codes and HVAC design criteria. Three methods are covered in Section 6: Ventilation Rate Procedure (VRP), Indoor Air Quality Procedure (IAQP) and Natural Ventilation Procedure (NVP). In the 2010 standard, the NVP is now section 6.4 (it was pre

    7、viously in Section 5). Exhaust requirements are now in Section 6.5. In addition to the convenience of bringing all three procedures into the same major section, these revisions have the effect of making exhaust requirements applicable regardless of which procedure is used. The VRP is a prescriptive

    8、procedure in which outdoor air intake rates are predetermined for various space types (occupancy categories) based on contaminant sources and source emission rates that are typical for the space type. The rates are intended to dilute and exhaust odorous bioeffluents from occupants and odorous and se

    9、nsory irritant contaminants from other sources common to that type of space. The VRP is intended to reduce concentrations to meet the sensory satisfaction of a substantial majority (greater than about 80%) of adapted occupants7 within the space. The IAQP is a performance-based procedure. Rather than

    10、 prescribing rates based on occupancy categories, rates are calculated based on contaminant source emission rates and desired indoor concentrations. The IAQP allows designers to take credit for source-control and removal measures, such as selection of low-emitting materials and gas-phase air 7 Adapt

    11、ed occupants are people who have occupied a space for a sufficient period of time that their sensory perceptions have become desensitized to some air contaminants, in particular bioeffluents (contaminants emitted by people, such as body odor), adaptation to which usually only takes a few seconds. Ad

    12、aptation to other contaminants such as volatile organic compounds (VOCs) can take much longer or not occur at all. People who have yet to adapt to air contaminants (unadapted occupants) are often called “visitors“ to the space. cleaning devices. The IAQP may also be used where the design is intended

    13、 to attain specific contaminant concentration limits or specific levels of acceptability of perceived indoor air quality. For instance, the design can be targeted to satisfy a higher or lower proportion of occupants than 80%or to focus on unadapted people (often called visitors) as opposed to adapte

    14、d occupants. The NVP is for systems that provide ventilation through openings (e.g. windows) in the building without the use of fans. In most cases, natural ventilation openings are under the manual control of the occupants of a space. The NVP specifies minimum opening size for the space to be venti

    15、lated. Natural ventilation should be distinguished from natural cooling, since the latter may have fans for ventilation but not have mechanical cooling. In the 2010 version, requirements for natural ventilation systems are more stringent than in previous versions of the standard. In particular, spaces served by natural ventilation systems (with certain exceptions) must also be served by