欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    ASHRAE 135 INT 3-2017 BACnet - A Data Communication Protocol for Building Automation and Control Networks.pdf

    • 资源ID:450201       资源大小:13.66KB        全文页数:2页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    ASHRAE 135 INT 3-2017 BACnet - A Data Communication Protocol for Building Automation and Control Networks.pdf

    1、Page 1 of 2 2017 ASHRAE. All Rights reserved. INTERPRETATION IC 135-2016-3 OF ANSI/ASHRAE STANDARD 135-2016 BACnet - A Data Communication Protocol for Building Automation and Control Networks Approval Date: June 26, 2017 Request from: Stephen Karg, Legrand/BCS Wattstopper, 2234 Rutherford Road, Carl

    2、sbad, CA 92008. Reference: This request for interpretation refers to the requirements presented in ANSI/ASHRAE Standard 135-2016, Clauses H.2.2.1 Offline Devices and H.2.3.2 Offline Devices, regarding consistent BACnet gateway behavior for offline devices. Background: In Clause H.2 about offline dev

    3、ices for virtual network gateways: H.2.2.1 Offline Devices When modeling devices as a virtual BACnet network of devices, communication timeout errors between the gateway and the non-BACnet device shall not result in the gateway returning an error, abort, or reject PDU in response to BACnet requests

    4、directed to the non-BACnet device. Instead, the gateway shall remain silent. This gives the best indication to the BACnet client that the device is offline. When a gateway has determined that a non-BACnet device is offline, it shall also not send I-Am or I-Have requests on behalf of that device. and

    5、 for single device gateways: H.2.3.2 Offline Devices Communication errors between the gateway and the non-BACnet device should be indicated via the Reliability property and Fault flag in the associated BACnet objects. The gateway should support initiation of event notifications to report such faults

    6、. Properties that exist in objects in the gateway device shall return values when read and not errors, even when the non-BACnet device from which those values are normally read is offline. It is not acceptable for this style of gateway device to not respond to confirmed requests just because the non

    7、-BACnet device is offline. The offline behavior of the two types of gateway models is inconsistent. The manner in which a gateway is modeled should have no effect on its network behavior (responses), and modeling as either Single Device Gateway or Virtual Network Gateways should allow both types of

    8、offline behavior. Devices which interact with either gateway model will have to expect either behavior. Consider a vendor modeling non-BACnet devices which acquire change-of-value or opportunistic data, sometimes with infrequent and asynchronous data updates, where the non-BACnet devices offline-sta

    9、tus are not able to be detected, or modeling non-BACnet devices with an especially large amount of data. In both cases, the vendor is forced to model as a Single IC 135-2016-3 Page 2 of 2 2017 ASHRAE. All Rights reserved. Device Gateway, rather than the more inter-data relationship apparent Virtual

    10、Network Gateways. Interpretation: A gateway modeled as a virtual BACnet network of devices may: 1) return positive responses to BACnet requests directed to the non-BACnet device if the non-BACnet device offline status is not detectable 2) and if the non-BACnet device offline status is detectable, th

    11、e amount of time that the gateway may continue to return positive responses to BACnet requests directed to the non-BACnet device is a local matter 3) or include objects that behave in the same manner as H.2.3.2 Offline Devices, where the device shall return values when read and not errors, and the o

    12、bjects use the Reliability property and the Fault flag in the associated BACnet objects to indicate their offline status. Question: Is this Interpretation correct? Answer: No Comments: H.2.2.1 and H.2.32 are mutually exclusive concepts and the text cannot be interpreted interchangeably. Once a Virtual Network Gateway has determined that a gatewayed virtual device is offline, then it must remain silent in response to requests for the gatewayed virtual device, thereby mimicking a physical route to the device that has gone offline.


    注意事项

    本文(ASHRAE 135 INT 3-2017 BACnet - A Data Communication Protocol for Building Automation and Control Networks.pdf)为本站会员(赵齐羽)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开