    ARMY MIL-DTL-8815 31-2009 FILTER ELEMENTS NON-CLEANABLE FLUID PRESSURE HYDRAULIC LINE 3 000 PSI 5 MICRON ABSOLUTE - 65 DEGREE F TO 275 DEGREE F《用于液压管路流体压力不能清洁的过滤器滤芯 操作压力为3000PSI 绝对.pdf

    • 资源ID:444456       资源大小:572.69KB        全文页数:42页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    ARMY MIL-DTL-8815 31-2009 FILTER ELEMENTS NON-CLEANABLE FLUID PRESSURE HYDRAULIC LINE 3 000 PSI 5 MICRON ABSOLUTE - 65 DEGREE F TO 275 DEGREE F《用于液压管路流体压力不能清洁的过滤器滤芯 操作压力为3000PSI 绝对.pdf

    1、 1 MIL-DTL-8815/31(AV) 16 October 2009 DETAIL SPECIFICATION SHEET FILTER ELEMENTS, NON-CLEANABLE, FLUID PRESSURE, HYDRAULIC LINE, 3,000 PSI, 5 MICRON ABSOLUTE, - 65F TO 275F This specification is approved for use by all Departments and Agencies of the Department of Defense. The complete requirements

    2、 for procuring the filter element described herein shall consist of this document and the latest issue in effect of Specification MIL-F-8815. AMSC N/A FSC 1650 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.Comments, suggestions, or questions on this document should

    3、 be addressed to the Army Research Development and Engineering Command, Aviation and Missile Research and Engineering Center, Attn: AMSRD-AMR-SE-TD-ST, 5400 Fowler Road, Redstone Arsenal, AL 35895-5000, or email to streviewamrdec.army.mil. INCH-POUND Provided by IHSNot for ResaleNo reproduction or n

    4、etworking permitted without license from IHS-,-,-MIL-DTL-8815/31(AV) 2 DRAWING NOTES: 1. Dimensions in inches unless otherwise specified. 2. Tolerances, decimals +/- .010, angles +/- 5. 3. Finish all over 100% except as noted. Surface texture in accordance with ASA B46.1 1962 (ANSI) only to machined

    5、 surfaces. 4. Material shall be in accordance with the procurement specification. 5. Drawing symbols per ASME Y14.5M 1994. 6. Weight of filter element is 0.13 lbs dry max. 7. Rated flow is 6.0 gpm. 1. SCOPE. 1.1 Scope. This specification covers hydraulic filter elements for the AH-64 series helicopt

    6、er. This specification describes: a multipass filtration performance test under cyclic flow and vibration conditions with continuous contaminant injection for hydraulic fluid power filter elements; a procedure for determining the contaminant capacity, particulate removal and differential pressure ch

    7、aracteristics; and specific changes, revisions, and modifications to paragraphs of the latest issue in effect of MIL-F-8815 2. APPLICABLE DOCUMENTS. 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents c

    8、ited in other sections or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whet

    9、her or not they are listed. 2.2 Government documents. 2.2.1 Specifications, Standards, and Handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the s

    10、olicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-5606 Hydraulic Fluid, Fire Resistant, Petroleum Base, Aircraft, Missile and Ordnance MIL-PRF-83282 Hydraulic Fluid, Fire Resistant, Synthetic Hydrocarbon Base, Aircraft MIL-PRF-87257 Hydraulic Fluid, Fire Resistant, Low Temperatur

    11、e, Synthetic Hydrocarbon Base, Aircraft and Missile Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-8815/31(AV) 3 (Copies of these documents are available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadel

    12、phia, PA 19111-5094, or online at http:/assist.daps.dla.mil/quicksearch/.) 2.3 Non-Government Publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

    13、INTERNATIONAL ORGANIZATION FOR STANDARDS (ISO) ISO 2941 Hydraulic fluid power Filter elements Verification of collapse/burst resistance ISO 3968 Hydraulic fluid power Filters - Evaluation of differential pressure versus flow characteristics ISO 4406 Hydraulic Fluid Power Fluids Method For Coding the

    14、 Level of Contaminants by Solid Particles ISO 11171 Hydraulic fluid power Calibration of automatic particle counters for liquids ISO 11943 Hydraulic fluid power On-line automatic particle counting systems for liquids Method of calibration and validation ISO 12103 Test Dust For Filter Evaluation ISO

    15、16889 Hydraulic fluid power Filters Multi-pass method for evaluating filtration performance of a filter element (Copies of these documents are available from the American National Standards Institute, 1819 L Street, NW, Washington, DC 20036, or online at http:/www.ansi.org). SOCIETY OF AUTOMOTIVE EN

    16、GINEERS (SAE) STANDARDS SAE AS478 Identification Marking Methods SAE ARP901 Bubble Point Test Method SAE AS4059 Fluids, Hydraulic, Aerospace Cleanliness Classification For Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-8815/31(AV) 4 SAE ARP4

    17、205 Aerospace Fluid Power-Hydraulic Filter Elements Method for Evaluating Dynamic Efficiency With Cyclic Flow SAE AS4716 Gland Design, O-Ring and Other Elastomeric Seals (Copies of this document are available from Society of Automotive Engineers, Inc., 400 Commonwealth Drive, Warrendale, PA 15096-00

    18、01, or online at http:/www.sae.org.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable l

    19、aws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 General. The individual item requirements shall be as specified in MIL-F-8815 and as modified herein. 3.2 Qualification. Items furnished under this specification shall be products that are manufactured by a manufa

    20、cturer authorized by the qualifying activity (The US Army Aviation and Missile Command (AMCOM) Aviation Engineering Directorate (AED) Propulsion Engineering Division for listing in the Qualified Product Database (QPD) before contract award (see 4 and 6). 3.3 Part Number. The Part Number shall consis

    21、t of the basic number of this specification sheet. Example: M8815/31(AV) 4. VERIFICATION 4.1 General. The quality assurance requirements and revisions for the filter elements defined by this specification sheet shall be in accordance with MIL-F-8815 and as modified herein. 4.1.1 Particle Counter Val

    22、idation Test Format. The validation test results shall be in accordance with (IAW) FIGURES B-1 through B-4. The acceptable sigma in FIGURES B-2 and B-3 can be obtained in accordance with paragraph 9.9 of ISO 11943. 4.1.2 Particle Counter Validation Test Format/Actual Test Results. The actual test re

    23、sults shall be IAW FIGURES B-5 through B-15. 4.2 Qualification Re-Qualification. All Army AH-64 Apache Helicopter Hydraulic filter elements will require full qualification testing to this military specification sheet. To remain qualified, the manufacturer shall re-qualify every 3 years (even if the

    24、contract is awarded for a longer duration). Contract awards will be made only for such products as have been tested prior to the time set for opening of bids, been tested by an Army approved Laboratory and approved Provided by IHSNot for ResaleNo reproduction or networking permitted without license

    25、from IHS-,-,-MIL-DTL-8815/31(AV) 5 by AMCOM AED Propulsion Engineering Division for inclusion in the Army Aviation applicable Qualified Products Database (QPD). There will be no exceptions to this requirement. The attention of the suppliers is called to this requirement and manufacturers are urged t

    26、o arrange to have the products that they propose to offer to the US Army tested for qualification, in order that they may be eligible to be awarded contracts or orders for the product covered by this specification. It is highly suggested that each filter manufacturer wishing to manufacture Army airc

    27、raft hydraulic filters under this specification provide the following information to the procuring activity (see 6.2.1). 4.3 ISO 16889 (see APPENDIX D for exceptions) Test Conditions. The filter elements furnished under this military specification sheet shall be subjected to the following test condi

    28、tions: Fluid Temperature: 160F 15F Test Fluid: MIL-PRF-83282 only AH-64 Flow Range: 1.5 to 6.0 gallons per minute or 5.7 to 22.7 liters per minute Flow Change Rate: 150 250 msec Terminal Pressure: 300 psid Test Dust: ISO Medium Test Dust Dilution: None Upstream Gravimetric: 3 mg/l Particle Counting:

    29、 4, 5, 6, 7, 14 and 20 microns. Particle counting shall be synchronized with flow changes as depicted in FIGURE A-3. At least one of the data points for upstream and downstream counts shall be taken after 7 seconds of changes in flow every flow cycle. Examples: Counting shall start after 7 seconds o

    30、f flow change from low to high flow and one other after high to low flow. Do not take particle count readings between flow changes. Counting shall continue as depicted in FIGURE A-3 for numerous specific events, as applicable and recorded in FIGURES B8 and B9. Cyclic Frequency 0.004 Hz (see profile

    31、of particle count synchronization) shall be as shown in FIGURE A-3. Mechanical Vibration: The mechanical vibration levels consist of a sinusoidal profile with frequency set at 38 Hz and peak acceleration set at 5gs. The Vibration shall be maintained during the Dynamic Efficiency Tests. Marking: Each

    32、 test article shall be laser marked or metal stamped with a minimum of 0.040 inch high characters or Vibro Etched for permanent unique identification IAW SAE AS478. Orientation is optional. Each test article shall be marked with the following information: Part Number/CAGE Vendor Part Number/Lot No 4

    33、.4 Responsibility for Qualification Re-qualification Requirement. The activity responsible for this specification and qualification and re-qualification requirement is US Army Aviation and Missile Command, Aviation Engineering Directorate, Propulsion Division, RDMR-AEP, Building 4488, Redstone Arsen

    34、al, Alabama 35898-5000. Based on the suggested requirement of Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-8815/31(AV) 6 the contractor providing recommended manufacturing planning and implementing a Change Control Board (CCB) for any and

    35、all changes, the requirement of re-qualification such as a lot change due to filter element material change, contract completion and break in delivery or the 3- year re-qualification requirement may be renegotiated. If manufacturing planning is not provided, the contractor will be removed from the q

    36、ualified vendors list and will have to re-qualify per paragraph 4.2 herein. 4.4.1 Quality Conformance. The quality conformance testing consists of the following tests: The Quality Conformance Testing outlined in MIL-F-8815 Table II will be followed except for the Degree of Filtration paragraph 4.7.2

    37、.4. Validation Test (if older than 6 months, the Validation Test shall be repeated), and three Dynamic Efficiency Tests on pre-conditioned filter elements shall be part of this requirement. Data shall be reported in Appendix B for this Validation and Conformance Test. 4.4.2 Quality Conformance Testi

    38、ng. The following changes constitute the quality conformance testing: Media, New Materials, Manufacturing Processes, Re-opening of the contract, and Company Buyout. 4.5 Filter Housing Approval. The filter housing, which shall house the filter element, shall be approved by the Government prior to qua

    39、lification of the filter element undergoing development and tests. 4.6 Filter Elements. Qualification test samples of filter elements (non-cleanable) shall consist of nine elements upon which qualification is desired. Manufacturers qualification tests shall be performed on these test samples in acco

    40、rdance with this military specification sheet as defined herein. 4.7 Retention. The retention of qualification shall consist of periodic verification to determine compliance of the qualified filter assembly and filter element with the requirements of this specification and applicable specification s

    41、heets. Verification shall be conducted at intervals not exceeding 3 years. 4.8 Individual Inspection/Examination. The individual inspection, specified in this specification shall be conducted on each filter element as shown in the FIGURE A-1. Each filter shall be carefully examined to determine conf

    42、ormance to the requirements of this specification and MIL-F-8815 for design, weight, workmanship, marking, conformance to applicable standards, government and manufacturers drawings, specifications, and standards for visible defects. Any filter element containing a defect shall be rejected. 4.9 Test

    43、 Fluid. 4.9.1 Hydraulic Test Fluid. Unless otherwise specified, the hydraulic fluid used for all tests shall conform to MIL-PRF-5606 (with no free water), or MIL-PRF-83282 (with no free water), or MIL-PRF-87257 (with no free water). These test fluids may be used for quality conformance tests as spec

    44、ified in this military specification sheet. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-8815/31(AV) 7 4.9.2 Test Fluid Cleanliness. For quality conformance tests and critical qualification tests, the test fluid shall be pre-cleaned to a c

    45、leanliness level equal to ISO 13/10/7 or SAE AS4059 (NAS) Class 1 or less. 4.10 Immersion/Thermal Cycling. All filter elements shall be immersed in hydraulic fluid for a total period of 192 hours. Filter elements shall be immersed in MIL-PRF-83282 or MIL-PRF-87257 at a fluid temperature of 275F for

    46、24 continuous hours followed immediately (within 10 minutes) by soaking at -65F using MIL-PRF-5606, MIL-PRF-87257, or MIL-PRF-83282. The filter element shall immediately (within 10 minutes) be placed back into the hot fluid bath of 275F for 24 continuous hours followed again by the cold -65F using M

    47、IL-PRF-5606, MIL-PRF-87257, or MIL-PRF-83282. This test cycle (hot/cold) shall be repeated four times, for a total immersion test time of 96 hours of the hot fluid bath and a total of 96 hours of the cold immersion bath on the test filter. Filters may remain immersed in test fluid at room temperatur

    48、e until the filters are ready for rinsing and visual inspection. This test will require two (2) environmental chambers to perform. 4.10.1 Post Immersion Visual Examination. Visually examine test article for evidence of deterioration after the Immersion Test above. Document the condition of the test article after this testing. Take photographs, including close-ups of filter media after testing. 4.10.2 Post Immersion Storage. After the Immersion Test and Post Immersion Visual Examination is completed, the filter shall remain in one of the three hydraulic fluids id


    注意事项

    本文(ARMY MIL-DTL-8815 31-2009 FILTER ELEMENTS NON-CLEANABLE FLUID PRESSURE HYDRAULIC LINE 3 000 PSI 5 MICRON ABSOLUTE - 65 DEGREE F TO 275 DEGREE F《用于液压管路流体压力不能清洁的过滤器滤芯 操作压力为3000PSI 绝对.pdf)为本站会员(tireattitude366)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!