1、 PAGE 1 OF 6 AMSC N/A FSC 6150 Distribution Statement A. Approved for public release, distribution is unlimited. INCH-POUND MIL-DTL-53126/2A 16 OCTOBER 2012 SUPERSEDING MIL-E-53126(ME) 20 April 1992 DETAIL SPECIFICATION SHEET POWER DISTRIBUTION, ILLUMINATION SYSTEMS, ELECTRICAL FEEDER SYSTEM, 100 AM
2、PS/PHASE (A/P) This specification is approved for use within US Army Research Development and Engineering Command, Communications and Electronics Research and Development Center, Product Realization Directorate, Department of the Army and is available for use by all Departments and Agencies of the D
3、epartment of Defense. The requirement for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-53126. 1. SCOPE 1.1. Scope. This specification sheet covers the detail requirements for the Power Distribution Illumination Systems Electrical (PDISE), Type I, model
4、: M100. 2. APPLICABLE DOCUMENTS 2.1. Drawings. The following Government drawings form a part of this specification sheet to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DRAWING# NOMENCLATURE DRAWING # NOMENCLATURE CECOM & PM-MEP Drawings -
5、Cage Code: 97403 and 30554 13229E6351 Feeder System, Electrical, Three Phase, 100 Amperes/Phase 13229E6327 Connector Assembly 100 AMP/PH Input Plug Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53126/2A PAGE 2 OF 6 (Copies of drawings requi
6、red by contractors in connection with specific acquisition functions should be obtained from: PROJECT MANAGER-MOBILE ELECTRIC POWER, 5850 Delafield Road, Bldg 324 FT BELVOIR VA 22060-5809.) 3. REQUIREMENTS 3.1. Requirements. The M100 PDISE shall be a self-contained, free-standing, man portable unit.
7、 The system shall be capable of distributing 100 A/P of electricity to all its outputs simultaneously, as specified herein. Type II 100 A/P feeder system3.2. Design. The M100 PDISE shall be IAW TA13229E6351 and as specified herein. 3.2.1. Dimensions. The M100 PDISE shall not be greater than the foll
8、owing dimensions: Length (Inches) Width (Inches) Height (Inches) 24.00 19.00 22.00 3.2.2. Weight. The M100 PDISE shall weigh no more than 60 pounds. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53126/2A PAGE 3 OF 6 3.2.3. M100 PDISE inputs
9、. The M100 PDISE shall have a single 3-phase input capable of handling 100 A/P. 3.2.3.1. Input circuit interrupter. The input circuit for the M100 PDISE shall be protected from overload by a properly sized circuit breaker. The circuit breaker shall act as a switch to activate/deactivate the circuit.
10、 3.2.3.2. Input Connector. The M100 PDISE shall have a 100 ampere, three phase, male, input receptacle IAW 13229E6327. 3.2.4. M100 PDISE Outputs The M100 PDISE shall have the following output circuits and connectors: Quantity Output Rating Ouput Connector P/N* 2 60 Amp, 3 phase M90556C32413P 2 40 Am
11、p, 3 phase M90556C32413P 2 20 Amp, 1 phase M3406D16-10S *Note: See 3.3.16.1 in MIL-DTL-53126. 3.2.4.1. Output circuit interrupters. Each output circuit shall be protected by a properly sized circuit breaker. The circuit breaker shall act as a switch to activate/deactivate the circuit. 3.2.5. Type I
12、accessories. The unit shall be provided with the following accessories: Quantity Description Reference* 1 Input interface cable assembly, rated at 100 amperes 3.3.18.1 2 100 A/P cable assemblies 3.3.18.3 4 Double-strap carriers 3.3.19.3 *Note: See requirement paragraph referenced MIL-DTL-53126. Prov
13、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53126/2A PAGE 4 OF 6 CARRYINGSTRAPSCINCHINGSTRAPSCARRYINGSTRAPSMARKING TAG(WHITE)JOININGSTRAP1.50 STK10.0027.754.75 3x 1.50JOININGSTRAPProvided by IHSNot for ResaleNo reproduction or networking perm
14、itted without license from IHS-,-,-MIL-DTL-53126/2A PAGE 5 OF 6 3.2.6. Wiring diagram. The circuits shall be configured as specified in the following wiring diagram:CB MAIN J2G6GND J2G6GND J2G6GND J2G6GND G2 G1 G4 G3 J1G6GND J1G6GND J1G6GND G4 G3 G2 J2N1NEUT N CB1C CB1B J1G6GND J1N1NEUT G1 N J2C1L3
15、J2B1L2 J2A1L1 C B A CB1A A B C J1A1CB1A J1B1CB1B J1C1CB1C J3C4CB3J3B4CB3J3A4CB3A C B A CB3A CB4A A B C J4A4CB4A J4B4CB4B J4C4CB4C N G J3N4NEUT J3G6GND CB3B CB3C G N J4G6GND J4N4NEUT CB4B CB4C BB GND L3 BB CB6C CB6B J6N4NEUT J6G6GND N G CB5C CB5B J5G6GND J5N4NEUT G N J8A12CB8 J8B12NEUT J8C12GND J6C4C
16、B6C J6B4CB6B J6A4CB6A 100 A 3 PHASE OUTPUT 40 A 3 PHASE OUTPUT 60 A 3 PHASE OUTPUT 20 A 1 PHASE OUTPUT A B C J8 J6 C B A J4 J2 CB812L1 CB8 CB6A L2 BB BB L1 NEUT BB CB5A CB712L3 CB7 J1 INPUT 100 A 3 PHASE J3 OUTPUT 60 A 3 PHASE A B C J5A4CB5A J5B4CB5B J5C4CB5C J5 OUTPUT 40 A 3 PHASE 20 A 1 PHASE OUTP
17、UT J7 J7C12GND J7B12NEUT J7A12CB7 C B A DS3CB1C DS2CB1B DS1CB1A DS3NBB DS2NBB DS1NBB DS3 DS2 DS1 CHASSIS GROUND TOP COVER CIRCUIT BREAKER MOUNTING PANEL LIGHT BRACKET CB3A4L1 CB3B4L2 CB3C4L3 CB4A4L1 CB4B4L2 CB4C4L3 CB5A4L1 CB5B4L2 CB5C4L3 CB6A4L1 CB6B4L2 CB6C4L3 CB1C1L3 CB1B1L2 CB1A1L1 3.2.7. This s
18、pecification sheet had no superseding “base”. The original publication was a performance specification that was used in-house by CR4. Since this specification is now a detailed military specification, this specification sheet is deemed necessary to capture the unique characteristics desired in the e
19、nd item. 3.2.8. Changes from previous issues: Marginal notations are not used in this revision to identify changes with respect to the previous issues because this detail specification sheet although a part of the base document, was not published because it was a document with limited coordination t
20、hat was used essentially by CR4. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53126/2A PAGE 6 OF 6 Concluding Material Custodian: Preparing Activity: Army - CR4 Army - CR4 (Project 6150-2013-002) Review Activities: DLA GS Note: The activit
21、ies listed above were interested in this document as of the date of this document. Since organization and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-