欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    AHRI GUIDELINE Q-2010 Content Recovery & Proper Recycling of Refrigerant Cylinders.pdf

    • 资源ID:422617       资源大小:167.56KB        全文页数:7页
    • 资源格式: PDF        下载积分:5000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要5000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    AHRI GUIDELINE Q-2010 Content Recovery & Proper Recycling of Refrigerant Cylinders.pdf

    1、 Price $10.00/$20.00$15.00 Copyright 19994, by Air-Conditioning and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office AHRI Guideline Q 2010 Guideline for Content Recovery & Proper Recycling of Refrigerant Cylinders Price $10.00 (Members) $20.00 (Non-Membe

    2、rs) Printed in U. S.A. Copyright 2010, by Air-Conditioning, Heating and Refrigeration Institute Registered United States Patent and Trademark Office IMPORTANT SAFETY RECOMMENDATIONS It is strongly recommended that the product be designed, constructed, assembled and installed in accordance with natio

    3、nally recognized safety requirements appropriate for products covered by this guideline. AHRI, as a manufacturers trade association, uses its best efforts to develop guidelines, employing state-of-the-art and accepted industry practices. However, AHRI does not certify or guarantee safety of any prod

    4、ucts, components or systems designed, tested, rated, installed or operated in accordance with these guidelines or that any tests conducted under its guidelines will be non-hazardous or free from risk. Note: This guideline supersedes AHRI Guideline Q-2001. TABLE OF CONTENTS SECTION PAGE Section 1. Pu

    5、rpose 1 Section 2. Scope . 1 Section 3. Definitions. 1 Section 4. Responsibilities . 2 Section 5. Procedure 2 APPENDICES Appendix A. References Normative . 4 Appendix B. References Informative 4 AHRI Guideline Q-2010 1 CONTENT RECOVERY AND PROPER RECYCLING OF REFRIGERANT CYLINDERS Section 1. Purpose

    6、 1.1 Purpose. For practical, safety and environmental reasons, there is a need for content recovery and proper recycling of refrigerant cylinders. This document is a guideline for content recovery and recycling of cylinders at the end of their useful service life. This document is not intended to be

    7、 an exhaustive listing of all good practices or requirements. Applicable federal, state and local requirements should be reviewed. 1.1.1 Intent. This guideline is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors, users, refrigerant reclaimers and

    8、 metal recyclers 1.1.2 Review and Amendment. This guideline is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This guideline is applicable to all U.S Department of Transportation (DOT) non-refillable and refillable fluorocarbon refrigerant cylinders, as defined i

    9、n Section 3, having water capacity greater than two pounds used to transport refrigerants sold in the United States. 2.2 Exclusions. This guideline does not apply to drums used to ship refrigerants. Section 3. Definitions All terms in this document will follow the standard industry definitions in th

    10、e current edition of ASHRAE Terminology of Heating, Ventilation, Air-Conditioning, and Refrigeration unless otherwise defined in this section. For the convenience of the users of this guideline, definitions for the more important terms employed in this guideline are provided below. 3.1 DOT-39 Non-Re

    11、fillable Cylinder. A single-use container produced in accordance with Title 49, Code of Federal Regulations, Section 178.65. 3.2 DOT Refillable Cylinder. A refillable container produced in accordance with the Title 49, Code of Federal Regulations, Section 178.36 (DOT 3A), 178.37 (DOT 3AA), 178.51 (D

    12、OT 4BA) or 178.61 (DOT 4BW) or as specified in an applicable special permit authorization as provided by the cylinder manufacturer. 3.3 Empty State. 3.3.1 Non-Refillable Cylinder. A cylinder whose contents have been evacuated to a vacuum of 15 inches of mercury, relative to standard atmospheric pres

    13、sure of 29.9 inches of mercury. 3.3.2 Refillable Cylinder. A cylinder whose contents have been recovered to an internal pressure of 0 psig or less with the intent to return it to the owner for proper handling. 3.4 End User. The individual or entity that renders the cylinder empty as defined in 3.3.

    14、3.5 Metal Recycler. A business or organization that processes or recycles industrial consumed scrapped material in a sound, environmentally responsible manner. 3.6 Recover. To remove refrigerant from a cylinder at the end of its useful service life and store it in a properly pressure rated recovery

    15、cylinder. 3.7 Should. “Should“ is used to indicate provisions which are not mandatory but which are desirable as good practice. AHRI Guideline Q-2010 2 3.8 Special Permit Cylinder. A cylinder that has been authorized by the DOT to be manufactured outside the scope of existing DOT regulations but in

    16、accordance with the requirements specified by DOT in a special permit. The requirements in the special permit may include design, composition, manufacture, testing, marking, and transportation criteria as well as special provisions. Section 4. Responsibilities 4.1 Responsibilities. It is the respons

    17、ibility of the End User to verify that any residual refrigerant contents are recovered from the cylinder while the cylinder is still under the control of the End User. Section 5. Procedure 5.1 Labeling Recommendations. 5.1.1 Recommended Label for DOT-39 Non-Refillable Cylinder. “Do not vent residual

    18、 pressure to the atmosphere. Recover residual contents using proper recovery equipment, hoses and gauges to a vacuum of 15 inches of mercury. Observe all precautions printed on the cylinder labels. After recovery, close valve and return for proper recycling or open valve and pierce rupture disc acco

    19、rding to Section 5.3. Do not reuse. Cylinder should be returned for proper metal recycling.” 5.1.2 Recommended Label for DOT Refillable Cylinder. “Do not vent residual pressure to the atmosphere. Observe all precautions printed on the cylinder labels. Close valves tightly. Promptly return to supplie

    20、r.” 5.2 Residual Content Recovery Procedures. Disposition of refrigerants must be in compliance with all applicable federal, state and local regulations. 5.2.1 Valves should remain closed at the onset of the refrigerant recovery process. 5.2.1.1 Recover refrigerant from cylinder into an appropriate

    21、pressure-rated recovery cylinder to empty state as listed in Section 3.3. 5.2.1.2 For non-refillable cylinders only, open the valve on the cylinder. Verify cylinder is empty. 5.2.2 IMPORTANT: DO NOT MIX REFRIGERANTS that have different ASHRAE numbers into the same recovery container. 5.3 Cylinder Re

    22、cycling Recommendations 5.3.1 DOT-39 Non-Refillable Cylinder. Do not reuse cylinders. Cylinder must be emptied of their contents as described in 5.2.1. After emptied of their contents, open valve. Cylinders may be rendered to a recyclable condition by the following method. WARNING: Failure to follow

    23、 these instructions for safe disposal of the non-refillable refrigerant cylinder can result in an immediate release of contents resulting in personal injury, property damage or both. Read all tank warnings for more information. 5.3.1.1 Place the tip of a flat-headed screwdriver on the inside serrati

    24、on of the rupture disc located on the shoulder of the tank (see Photo 1). Photo 1: Placement of Screwdriver for Piercing AHRI Guideline Q-2010 3 5.3.1.2 With a hammer or mallet, LIGHTLY tap the handle of the screwdriver to pierce the rupture disc open (see Photo 2). Photo 2: Pierce Rupture Disc 5.3.

    25、1.3 Carefully, completely open the rupture disc. With a permanent magic marker, draw a large circle around the open rupture disk and write the word “EMPTY” on the tank (see Photo 3). Photo 3: Open Rupture Disc 5.3.1.4 Once the rupture disc is open, the tank can be recycled with other steel recyclabl

    26、es at your local steel recycling center. 5.3.2 DOT Refillable Cylinder. Valves should be closed tightly and hood cap securely placed, if applicable. Cylinders should be returned to supplier or owner. AHRI Guideline Q-2010 4 APPENDIX A. REFERENCES NORMATIVE None. APPENDIX B. REFERENCES INFORMATIVE B1

    27、 Listed here are all guidelines, handbooks and other publications essential to the formation and implementation of this guideline. All references in this appendix are considered as part of the guideline. B1.1 AHRI Guideline K-2009, Containers for Recovered Fluorocarbon Refrigerants, 2009, Air-Condit

    28、ioning, Heating, and Refrigeration Institute, 2111 Wilson Boulevard, Suite 500, Arlington, VA 22209, U.S.A. B1.2 ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration, Second Edition, 1991, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle, NE, Atlanta, GA 30329, U.S.A. B1.3 Title 49 Code of Federal Regulationss contact: Superintendent of Documents Government Printing Office Washington, DC 20410, U.S.A., (202) 512-1800