    AHRI 1270 I-P-2015 Requirements for Seismic Qualification of HVACR Equipment.pdf

    • 资源ID:422492       资源大小:566.12KB        全文页数:32页
    • 资源格式: PDF        下载积分:5000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要5000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    AHRI 1270 I-P-2015 Requirements for Seismic Qualification of HVACR Equipment.pdf

    1、 2015 Standard for Requirements for Seismic Qualification of HVACR Equipment AHRI Standard 1270 (I-P) Price $10.00 (M) $20.00 (NM) Copyright 2015, by Air-Conditioning Heating and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office IMPORTANT SAFETY DISCLAIME

    2、R AHRI does not set safety standards nor does it certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installed a

    3、nd operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or gua

    4、rantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes the 2015 version. For SI ratings, see AHRI Standard 1271 (SI)-2015. TABLE OF CONTENTS Section 1. Purpose . 1 Section 2. Scope 1 Section 3. Definitions 1 Section 4. S

    5、ymbols 4 Section 5. Equipment 4 Section 6. Seismic Demand . 8 Section 7. Seismic Capacity of Equipment by Analysis 10 Section 8. Seismic Capacity of Equipment by Testing 13 Section 9. Report Requirements 18 Section 10. Seismic Rating of Equipment . 211 TABLES Table 1. Seismic Performance Level; Func

    6、tionality (per ASCE 7 Section 13.2.2) . 6 Table 2. Seismic Performance Level; Structural Integrity (per ASCE 7 Section 13.2.1) 7 Table 3. Load Combinations . 12 Table 4. Analytical Procedures 123 Table 5. Functional Requirements For Designated Seismic Systems 15 Table 6. Allowable Minor Damage State

    7、s for Designated Seismic Systems 16 Table 7. Allowable Minor Damage States for Components of Designated Seismic System Equipment 17 APPENDICIES Appendix A. References Normative . 222 Appendix B. References Informative . 23 Appendix C. ASCE 7 Commentary C13 Seismic Design Requirements for Nonstructur

    8、al Components -Informative . 25 Appendix D. Seismic Design of Liquid Storage Tanks-Informative . 26 Appendix E. Software Validation- Normative 28 FIGURES Figure 1. Qualification Flowchart . 5 Figure 2. RRS, Normalized For Equipment 8 AHRI STANDARD 1270 (I-P)-2015 1 REQUIREMENTS FOR SEISMIC QUALIFICA

    9、TION OF HVACR EQUIPMENT Section 1. Purpose 1.1 Purpose. The purpose of this standard is to define the requirements for seismic qualification of mechanical HVACR Equipment. The 2012 International Building Code (IBC) includes a number of provisions for seismic design and certification of nonstructural

    10、 components. These provisions are intended to improve the performance of non-essential and essential nonstructural systems subject to strong ground shaking. Both the IBC and the American Society of Civil Engineers Standard SEI/ASCE 7 (ASCE 7) contain requirements for qualification of Equipment. Sect

    11、ion 2. Scope 2.1 Scope. This standard applies to the following Equipment: Fan Coil Units, Unit Ventilators, Air Handling Units, Coils, Air-to-Air Heat Exchangers, Vertical Packaged Air Conditioners and Heat Pumps, Packaged Terminal Equipment, Dehumidifiers, Flow and Contaminant Controls, Furnaces, H

    12、umidifiers, Liquid Chillers, Thermal Storage Equipment, Unitary Air Conditioners and Heat Pumps (including Ductless Equipment), and Water-Source Heat Pumps. This standard does not apply to any other products. This standard describes the methods for equipment qualification and the process to determin

    13、e equipment Seismic Capacity. The applicability of this standard to equipment not specifically listed in the scope has not been considered. Section 3. Definitions All terms in this document shall follow the standard industry definitions in the current edition of ASHRAE Terminology website (https:/ww

    14、w.ashrae.org/resources-publications/free-resources/ashrae-terminology) or the International Code Council Evaluation Services (ICC-ES) Acceptance Criteria AC156 (AC156), unless otherwise defined in this section. 3.1 Active Component. A component or sub-assembly that is critical to the functional perf

    15、ormance of the equipment that includes moving or rotating parts, electrical parts such as switches or relays, or other internal component that is sensitive to earthquake forces. Examples of Active Components include: fans, variable frequency drives, control panels, and damper assemblies. 3.2 Active

    16、Equipment. Equipment that contains Active Components. 3.3 Allowable Stress Design (ASD). A comparison of the stresses in the connections/elements defined in the Equipment Force-Resisting System (EFRS) determined by analysis from the effects of design loads to the allowable stresses for the material

    17、used in the EFRS. 3.4 Attachments. The devices or hardware used to secure or restrain the Equipment to the building structure. Attachments or restraints of the Equipment include anchor bolting, welded connections and mechanical fasteners. 3.5 Attachment Point. The point at which the Equipment is con

    18、nected to the building structure. This connection point is designed to transfer seismic forces between the structure and the Equipment. AHRI STANDARD 1270 (I-P)-2015 2 3.6 Certificate of Compliance. A certificate stating the Seismic Capacity of Equipment determined using methods of this standard. 3.

    19、7 Certification Response Spectrum (CRS). For shake table testing, certification will be performed based on a Required Response Spectrum (RRS) which determines the input motion at the equipment attachment. For this application, the CRS is the RRS. For dynamic analysis certification of Equipment, the

    20、CRS defines the forcing function in terms of octaves used by the analysis program to define the input of motion at the equipment attachment. The CRS constitutes the Seismic Capacity of the Equipment if it satisfies the acceptance criteria as defined in this standard. 3.8 Component. Devices that can

    21、be individually qualified per this standard and joined with other Pre-Qualified Components or EFRS qualified separately for multi-component Equipment such as motors, coils, fans, valves, dampers, and etc. 3.9 Component Amplification Factor. A factor for a component that is not attached to the Equipm

    22、ents substructure at the base, but somewhere above in the unit. The unit may have some internal amplification because of the response to the dynamic forcing functions. For example, a fan on top of a cooling tower may see higher seismic shaking than if it was attached to the base. This higher demand

    23、must be defined so the fan (Component) will need to have a higher capacity in order for the cooling tower itself to be rated at the demand at the attachment point. 3.0 Damping. Energy dissipation mechanism that reduces amplification and broadens the vibratory response. Damping is expressed as a perc

    24、entage of critical Damping applied near the natural frequency of the Equipment. 3.11 Design Earthquake. The earthquake effects that are two-thirds of the corresponding maximum considered earthquake (MCE) effects. 3.12 Designated Seismic System. The architectural, electrical and mechanical systems an

    25、d their Equipment and components that require design in accordance with Chapter 13 of ASCE 7 and for which the importance factor, Ip, is equal to 1.5 in accordance with Section 13.1.3 of ASCE 7. 3.13 Equipment. Products manufactured to perform HVACR functions. These products are manufactured by comb

    26、ining components with an EFRS. In context of this standard, these products are evaluated to determine the maximum Seismic Demand that the HVACR Equipment will survive or function following a seismic event. 3.14 Equipment Qualified by Test (EQT). Equipment identified to be qualified by shake table te

    27、st. 3.15 Equipment Force-Resisting System (EFRS). A system of elements within the Equipment that include brackets, braces, frames, and struts that provides the seismic load path transmitting seismic forces to the equipment Attachment Points. 3.16 Flexible Equipment. Equipment, including its attachme

    28、nt and force-resisting structural system, that has a fundamental period greater than 0.06 second (frequency less than 16.67 Hz). 3.17 Functional Requirements. High level actions that the Equipment must achieve that define the Equipment to be functional. 3.18 Load and Resistance Factor Design (LRFD).

    29、 Comparison of the load on the connections/elements defined in the EFRS determined by analysis from the effects of design loads to the allowable strength for the configuration of the connection and material used in the EFRS. 3.19 Performance Requirements. Parameters that can be measured such as pres

    30、sure, revolutions per minute (RPM), flow rates, and physical dimensions. The Performance Requirements are measured before and after a shake table test and must be equivalent or within tolerance for the functional requirements to be met. AHRI STANDARD 1270 (I-P)-2015 3 3.20 Pre-Qualified Component. A

    31、ctive or energized components seismically pre-qualified to a specific g-level used in multi-component Equipment. 3.21 Required Response Spectrum (RRS). The response spectrum as defined by AC156 to create the required demand on the Equipment. The response spectrum is generated from formulas available

    32、 in AC156 and is used as the Seismic Capacity in the certification of Equipment. 3.22 Rigid Equipment. Equipment, including its Attachments and EFRS, that has a fundamental period less than or equal to 0.06 second (frequency greater than or equal to 16.67 Hz). 3.23 Rugged Component. A nonstructural

    33、component that has been shown to consistently function after design earthquake level or greater seismic events based on past earthquake experience data or past seismic testing when adequately anchored or supported. The classification of a nonstructural component as rugged shall be based on a compari

    34、son of the specific component with components of similar strength and stiffness. Common examples of rugged components include: AC motors, compressors and base mounted horizontal pumps. 3.24 Rugged Equipment. Equipment judged to survive design earthquake motion without Significant Loss of Function an

    35、d qualified by engineering judgment such that the Equipment does not require further testing or analysis. 3.25 Seismic Capacity. The maximum analytical or test acceleration at which the Equipment can satisfy the performance criteria as defined in Section 5. 3.26 Seismic Demand. Seismic forces result

    36、ing from ground motion that are defined in the IBC. The maximum design acceleration of the seismic forces is the demand. The Seismic Demand can be a single value that corresponds to the maximum value of the RRS. 3.27 “Shall,“ “Should,“ “Recommended,“ or “It Is Recommended.“ “Shall,“ “should,“ “recom

    37、mended,“ or “it is recommended“ shall be interpreted as follows: 3.27.1 Shall. Where “shall“ or “shall not“ is used for a provision specified, that provision is mandatory if compliance with the standard is claimed. 3.27.2 Should, Recommended, or It Is Recommended. “Should,“ “recommended,“ or “it is

    38、recommended“ is used to indicate provisions which are not mandatory but which are desirable as good practice. 3.28 Significant Loss of Function. The functional state of Equipment or Components that cannot be restored in a timely fashion to their original function by competent technicians after desig

    39、n earthquake motion because the Equipment or Components require parts that are not normally stocked locally or not readily available. 3.29 Test Response Spectrum (TRS). The acceleration response spectrum developed by the motion of the shake table to provide an input motion that simulates an earthqua

    40、ke for the qualification of Equipment. This motion is created to develop the CRS at the equipment attachment point. The TRS shall envelope the RRS with limited exceptions. 3.30 Transmissibility. A non-dimensional ratio that defines the force amplitude factor of load path in the EFRS in terms of stea

    41、dy-state forced vibration. The ratio may be expressed in terms of force, displacement, velocity, or acceleration and is used to characterize resonant modes of structural vibration. 3.31 Zero Period Acceleration (ZPA). The maximum peak acceleration used to derive a specific applied time history spect

    42、rum (the peak acceleration AFLXis greater than the ZPA). AHRI STANDARD 1270 (I-P)-2015 4 Section 4. Symbols 4.1 Symbols. The following symbols are used in this document. Refer to ASCE 7 and AC156 for additional information. AFLX-H= The probable maximum horizontal spectral acceleration that Flexible

    43、Equipment will experience in a seismic event defined by AC156. AFLX-V= The probable maximum vertical spectral acceleration that Flexible Equipment will experience in a seismic event defined by AC156. ap= In-structure equipment amplification factor. The aprepresents a comparison of the equipments nat

    44、ural frequency to the fundamental frequencyof the building structure as determined in ASCE 7 Section 13.6-1. ARIG-H= Horizontal spectral acceleration that Rigid Equipment will experience in a seismic event defined by AC156. ARIG-V= Vertical spectral acceleration that Rigid Equipment will experience

    45、in a seismic event defined by AC156. D = Dead Load as used in the load combination formulas. F = Load due to fluids with well-defined pressures and maximum heights. Fp= An equivalent horizontal static force that represents the dynamic accelerations of a seismic event used in the prescriptive method

    46、identified by ASCE 7 Section 13.3.1. The horizontal seismic design force is applied at the equipments center of gravity. H = Load due to lateral earth pressure, ground water pressure or pressure of bulk materials. h = Average building/structure roof height with respect to grade as defined in ASCE 7

    47、Section 13.3.1. Ip= Equipment importance factor. Iprepresents the life-safety importance factor of the Equipment or Component as defined in ASCE 7 Section 13.1.3. L = Live load. = Redundancy factor based on the extent of structural redundancy present in a structure as defined in ASCE 7, Section 12.3

    48、.4. = 1.0 for nonstructural components. QE= Earthquake Load as used in the load combination formulas. Rp= Equipment response modification factor. Rprepresents the capability of the Equipment and attachment to absorb energy, as defined in ASCE 7 Section 13.6.1. S = Snow load. SDS = Design spectral re

    49、sponse acceleration at short period (0.2 secs), as determined in ASCE 7 Section 11.4.4. Wp= Equipment operating weight, including all contents, as defined in ASCE 7 Section 13.3.1. z = Height of the equipment attachment to the structure with respect to grade (ground level) as defined in ASCE 7 Section 13.3.1. For items at or below grade, z shall be 0.0 and not negative. Section 5. Equipment 5.1 Applicability. Equipment shall be seismically qualified per the requirements contained in this standard. The qualification processes are shown in Figure 1


    注意事项

    本文(AHRI 1270 I-P-2015 Requirements for Seismic Qualification of HVACR Equipment.pdf)为本站会员(吴艺期)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起