欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    BS PD ISO TS 19590-2017 Nanotechnologies -- Size distribution and concentration of inorganic nanoparticles in aqueous media via single particle inductively coupled plasma mass spec.pdf

    • 资源ID:399326       资源大小:3.99MB        全文页数:30页
    • 资源格式: PDF        下载积分:5000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要5000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS PD ISO TS 19590-2017 Nanotechnologies -- Size distribution and concentration of inorganic nanoparticles in aqueous media via single particle inductively coupled plasma mass spec.pdf

    1、PD ISO/TS 19590:2017 Nanotechnologies Size distribution and concentration of inorganic nanoparticles in aqueous media via single particle inductively coupled plasma mass spectrometry BSI Standards Publication WB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06PD ISO/TS 19590:2017 PUBLISHED DOCU

    2、MENT National foreword This Published Document is the UK implementation of ISO/TS 19590:2017. The UK participation in its preparation was entrusted to Technical Committee NTI/1, Nanotechnologies. A list of organizations represented on this committee can be obtained on request to its secretary. This

    3、publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017. Published by BSI Standards Limited 2017 ISBN 978 0 580 90502 5 ICS 07.120 Compliance with a British Standard cannot confer im

    4、munity from legal obligations. This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2017. Amendments/corrigenda issued since publication Date Text affectedPD ISO/TS 19590:2017 ISO 2017 Nanotechnologies Size distribution and concentration

    5、of inorganic nanoparticles in aqueous media via single particle inductively coupled plasma mass spectrometry Nanotechnologies - Distribution de taille et concentration de nanoparticules inorganiques en milieu aqueux par spectromtrie de masse plasma induit en mode particule unique TECHNICAL SPECIFICA

    6、TION ISO/TS 19590 Reference number ISO/TS 19590:2017(E) First edition 2017-03PD ISO/TS 19590:2017ISO/TS 19590:2017(E)ii ISO 2017 All rights reserved COPYRIGHT PROTECTED DOCUMENT ISO 2017, Published in Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be rep

    7、roduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the request

    8、er. ISO copyright office Ch. de Blandonnet 8 CP 401 CH-1214 Vernier, Geneva, Switzerland Tel. +41 22 749 01 11 Fax +41 22 749 09 47 copyrightiso.org www.iso.orgPD ISO/TS 19590:2017ISO/TS 19590:2017(E)Foreword iv Introduction v 1 Scope . 1 2 Normative references 1 3 T erms and definitions . 1 4 Abbre

    9、viated terms 2 5 Conformance . 2 6 Procedure. 3 6.1 Principle 3 6.2 Apparatus and equipment 3 6.3 Chemicals, reference materials and reagents . 3 6.3.1 Chemicals . 3 6.3.2 Reference materials . 3 6.3.3 Reagents 4 6.4 Samples . 4 6.4.1 Amount of sample . 4 6.4.2 Sample dilution . 5 6.5 Instrumental s

    10、ettings and performance check . 5 6.5.1 Settings of the ICP-MS system 5 6.5.2 Checking the performance of the ICP-MS system 5 6.6 Determination of the transport efficiency . 6 6.6.1 Determination of transport efficiency based on measured particle frequency 6 6.6.2 Determination of transport efficien

    11、cy based on measured particle size 7 6.7 Determination of the linearity of response 8 6.8 Determination of the blank level . 8 6.9 Analysis of aqueous suspension . 8 6.10 Data conversion 9 7 Results . 9 7.1 Calculations 9 7.1.1 Calculation of the transport efficiency .10 7.1.2 Calculation of the ICP

    12、-MS response 10 7.1.3 Calculation of particle concentration and size 10 7.1.4 Calculation of the particle concentration detection limit 11 7.1.5 Calculation of the particle size detection limit12 7.1.6 Calculation of ionic concentration .13 7.2 Performance criteria .13 7.2.1 Transport efficiency .13

    13、 7.2.2 Linearity of the calibration curve .13 7.2.3 Blank samples .13 7.2.4 Number of detected particles 13 8 Test report 13 Annex A (informative) Calculation spreadsheet15 Bibliography .19 ISO 2017 All rights reserved iii Contents PagePD ISO/TS 19590:2017ISO/TS 19590:2017(E) Foreword ISO (the Inter

    14、national Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has

    15、been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical st

    16、andardization. The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in acco

    17、rdance with the editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. De

    18、tails of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www .iso .org/ patents). Any trade name used in this document is information given for the convenience of users and does not constitute

    19、 an endorsement. For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the

    20、following URL: w w w . i s o .org/ iso/ foreword .html. This document was prepared by ISO/TC 229, Nanotechnologies.iv ISO 2017 All rights reservedPD ISO/TS 19590:2017ISO/TS 19590:2017(E) Introduction This document was developed in response to the worldwide demand of suitable methods for the detectio

    21、n and characterization of nanoparticles in food and consumer products. Products based on nanotechnology or containing engineered nanoparticles are already in use and beginning to impact the food-associated industries and markets. As a consequence, direct and indirect consumer exposure to engineered

    22、nanoparticles (in addition to natural nanoparticles) becomes more likely. The detection of engineered nanoparticles in food, in samples from toxicology and in exposure studies therefore becomes an essential part in understanding the potential benefits, as well as the potential risks, of the applicat

    23、ion of nanoparticles. Single particle inductively coupled plasma mass spectrometry (spICP-MS) is a method capable of detecting single nanoparticles at very low concentrations. The aqueous sample is introduced continuously into a standard ICP-MS system that is set to acquire data with a high time res

    24、olution (i.e. a short dwell time). Following nebulization, a fraction of the nanoparticles enters the plasma where they are atomized and the individual atoms ionized. For every particle atomized, a cloud of ions results. This cloud of ions is sampled by the mass spectrometer and since the ion densit

    25、y in this cloud is high, the signal pulse is high compared to the background (or baseline) signal if a high time resolution is used. A typical run time is 30 s to 200 s and is called a “time scan.” The mass spectrometer can be tuned to measure any specific element, but due to the high time resolutio

    26、n, typically only one m/z value will be monitored during a run (with the current instruments). The number of pulses detected per second is directly proportional to the number of nanoparticles in the aqueous suspension that is being measured. To calculate concentrations, the transport efficiency has

    27、to be determined first using a reference nanoparticle. The intensity of the pulse and the pulse area are directly proportional to the mass of the measured element in a nanoparticle, and thereby to the nanoparticles diameter to the third power (i.e. assuming a spherical geometry for the nanoparticle)

    28、. This means that for any increase of a particles diameter, the response will increase to the third power and therefore a proper validation of the response for each size range of each composition of nanoparticle is required. Calibration is best performed using a reference nanoparticle material; howe

    29、ver, such materials are often not available. Therefore, calibration in this procedure is performed using ionic standard solutions of the measured element under the same analytical condition. The data can be processed by commercially available software or it can be imported in a custom spreadsheet pr

    30、ogram to calculate the number and mass concentration, the size (the spherical equivalent diameter) and the corresponding number-based size distribution of the nanoparticles. In addition, mass concentrations of ions present in the same sample can be determined from the same data. The interested reade

    31、r can consult References 1 to 4 for further information. ISO 2017 All rights reserved vPD ISO/TS 19590:2017PD ISO/TS 19590:2017Nanotechnologies Size distribution and concentration of inorganic nanoparticles in aqueous media via single particle inductively coupled plasma mass spectrometry 1 Scope Thi

    32、s document specifies a method for the detection of nanoparticles in aqueous suspensions and characterization of the particle number and particle mass concentration and the number-based size distribution using ICP-MS in a time-resolved mode to determine the mass of individual nanoparticles and ionic

    33、concentrations. The method is applicable for the determination of the size of inorganic nanoparticles (e.g. metal and metal oxides like Au, Ag, TiO 2 , BVO 4 , etc.), with size ranges of 10 nm to 100 nm (and larger particles up to 1 000 nm to 2 000 nm) in aqueous suspensions. Metal compounds other t

    34、han oxides (e.g. sulfides, etc.), metal composites or coated particles with a metal core can be determined if the chemical composition and density are known. Particle number concentrations that can be determined in aqueous suspensions range from 10 6particles/L to 10 9particles/L which corresponds t

    35、o mass concentrations in the range of approximately 1 ng/L to 1 000 ng/L (for 60 nm Au particles). Actual numbers depend on the type of mass spectrometer used and the type of nanoparticle analysed. In addition to the particle concentrations, ionic concentrations in the suspension can also be determi

    36、ned. Limits of detection are comparable with standard ICP-MS measurements. Note that nanoparticles with sizes smaller than the particle size detection limit of the spICP-MS method may be quantified as ionic. The method proposed in this document is not applicable for the detection and characterizatio

    37、n of organic or carbon-based nanoparticles like encapsulates, fullerenes and carbon nanotubes (CNT). In addition, it is not applicable for elements other than carbon and that are difficult to determine with ICP- MS. Reference 5 gives an overview of elements that can be detected and the minimum parti

    38、cle sizes that can be determined with spICP-MS. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the late

    39、st edition of the referenced document (including any amendments) applies. ISO/TS 80004-1, Nanotechnologies Vocabulary Part 1: Core terms 3 T erms a nd definiti ons For the purposes of this document, the terms and definitions given in ISO/TS 80004-1 and the following apply. ISO and IEC maintain termi

    40、nological databases for use in standardization at the following addresses: IEC Electropedia: available at h t t p :/ www .electropedia .org/ ISO Online browsing platform: available at h t t p :/ www .iso .org/ obp 3.1 nanoparticle nano-object with all three external dimensions in the nanoscale SOURC

    41、E: ISO/TS 80004-2:2015, modified TECHNICAL SPECIFICATION ISO/TS 19590:2017(E) ISO 2017 All rights reserved 1PD ISO/TS 19590:2017ISO/TS 19590:2017(E) 3.2 aqueous suspension particle suspension whose suspending phase is composed of water 3.3 inductively coupled plasma mass spectrometry ICP-MS analytic

    42、al technique comprising a sample introduction system, an inductively coupled plasma source for ionization of the analytes, a plasma/vacuum interface and a mass spectrometer comprising an ion focusing, separation and detection system 3.4 dwell time time during which the ICP-MS detector collects and i

    43、ntegrates pulses Note 1 to entry: Following integration, the total count number per dwell time is registered as one data point, expressed in counts, or counts per second. 3.5 t r a n s p or t ef f ic ienc y p a r t i c l e t r a n s p o r t e f f i c i e n c y ne bu l i z at ion e f f ic ie nc y rat

    44、io of the number of particles or mass of solution entering the plasma to the number of particles or mass of solution aspirated to the nebulizer 3.6 particle number concentration number of particles divided by the volume of a suspension, e.g. particles/L 3.7 particle mass concentration total mass of

    45、the particles divided by the volume of a sample, e.g. ng/L 3.8 number-based particle size distribution list of values that defines the relative amount by numbers of particles present according to size 4 Abbreviated terms spICP-MS single particle inductively coupled plasma mass spectrometry (for the

    46、definition of ICP-MS, see 3.3 or ISO/TS 80004-6:2013, 4.22) 5 Conformance This method is restricted to aqueous suspensions of pure nanoparticles, aqueous extracts of materials or consumer products, aqueous digests of food or tissue samples, aqueous toxicological samples or environmental water sample

    47、s. The applicability of the method for such samples should be evaluated by the user. Information about sample processing of non-aqueous samples can be found in the literature. Aqueous environmental samples are filtrated and diluted 6 , food and toxicological samples are chemically or enzymatically d

    48、igested and diluted 78 . However, to relate particle number or mass concentrations in aqueous suspensions to the concentrations in the original sample information on extraction, efficiency and matrix effects are required. Additional validation by the user is required.2 ISO 2017 All rights reservedPD

    49、 ISO/TS 19590:2017ISO/TS 19590:2017(E) 6 Procedure 6.1 Principle When nanoparticles are introduced into an ICP-MS system, they produce a plume of analyte ions. The plumes corresponding to individual nanoparticles can be detected as a signal spike in the mass spectrometer if a high time resolution is used. Using dwell times of 10 ms and an appropriate dilution of the nanoparticle suspension allows the detection of individual nanoparticles, hence the name “single particle”-ICP-MS. Dilution is often required to avoid violation


    注意事项

    本文(BS PD ISO TS 19590-2017 Nanotechnologies -- Size distribution and concentration of inorganic nanoparticles in aqueous media via single particle inductively coupled plasma mass spec.pdf)为本站会员(bowdiet140)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!