    BS PD 6662-2010 Published Document Scheme for the application of European standards for intrusion and hold-up alarm systems《发布的文档 入侵和拦截警报系统用欧洲标准的应用方案》.pdf

    • 资源ID:397139       资源大小:1,022KB        全文页数:16页
    • 资源格式: PDF        下载积分:5000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要5000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS PD 6662-2010 Published Document Scheme for the application of European standards for intrusion and hold-up alarm systems《发布的文档 入侵和拦截警报系统用欧洲标准的应用方案》.pdf

    1、raising standards worldwide NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BSI Standards Publication PD 6662:2010 PUBLISHED DOCUMENT Scheme for the application of European standards for intrusion and hold-up alarm systems This publication is not to be regarded as a British St

    2、andard.PD 6662:2010 PUBLISHED DOCUMENT Publishing and copyright information The BSI copyright notice displayed in this document indicates when the document was last issued. BSI 2010 ISBN 978 0 580 62025 6 ICS 13.310 The following BSI references relate to the work on this standard: Committee referenc

    3、e GW/1 Draft for comment 09/30203716 DC Publication history First published March 2000 Second edition, August 2004 Third (present) edition May 2010 Amendments issued since publication Date Text affected BSI 2010 i PD 6662:2010 PUBLISHED DOCUMENTContents Foreword ii 1 Scope 1 2 Abbreviations 1 3 Sche

    4、me content 1 4 Claims of compliance 4 5 Identity cards 5 6 Risk assessment 5 Annexes Annex A (normative) UK specific recommendations 6 Annex B (informative) UK specific guidance 6 Annex C (informative) Additional guidance 8 Bibliography 10 List of tables Table B.1 Duration of alternative power suppl

    5、y 7 Summary of pages This document comprises a front cover, an inside front cover, pages i to ii, pages 1 to 10, an inside back cover and a back cover.PD 6662:2010 ii BSI 2010 PUBLISHED DOCUMENTForeword Publishing information This Published Document is published by BSI and came into effect on 31 May

    6、 2010. It was prepared by Subcommittee GW/1/2, Installed alarm systems, under the authority of Technical Committee GW/1, Electronic security systems. A list of organizations represented on this committee can be obtained on request to its secretary. Supersession The provisions of this standard become

    7、 effective immediately and can be used as soon as suitable products are available to comply with its recommendations. However, the technical committee recognizes that suppliers of products and services within the scope of this standard will require time to comply. For this reason, PD6662:2004+A2:200

    8、6 will be withdrawn on 31 May 2012. Relationship with other publications A series of European Standards for intrusion and hold-up alarm systems (I b) the name of the employee and employees signature; c) the expiry date of the identity card (not more than three years from the date of issue); and d) a

    9、 current photograph of the employee. Employees should be instructed to carry their identity cards while on duty. Identity cards should be formally withdrawn from employees renewing their cards or leaving the organization, and destroyed in a secure manner, which should preclude any further use of the

    10、 withdrawn card. A record of identity cards issued should be maintained. This record should also indicate the status and location of withdrawn cards, e.g. whether they have been destroyed or lost, or where they are held by the employee/organization.6 Risk assessment The context in which the term “ri

    11、sk assessment” is included within DD CLC/TS 50131-7 relates solely to the determination of the grade and the design of the I&HAS. A suitable form of wording for inclusion in documentation relating to the location (risk) survey for an I&HAS, is as follows: “This assessment relates solely to the gradi

    12、ng and design of the I&HAS according to DD CLC/TS 50131-7. The grading and design are based on a survey of the premises and information available at the time, including any valuation(s) or other information provided by the customer or the customers representative (e.g. the insurer).”PD 6662:2010 6 B

    13、SI 2010 PUBLISHED DOCUMENTAnnex A (normative) UK specific recommendationsA.1 Hold-up devices For I&HASs installed under this scheme and which include hold-up device, these devices should conform to BS 4737-3.14:1986, 3.2b) or 3.2c).A.2 Police response Systems that are installed as Grade 1 or Grade 2

    14、, Option X (see B.3), should not be used to initiate a police response.A.3 BS EN 50131-1:2006+A1:2009, 8.3.1, Level 2 authorization for level 3 access NOTE BS EN 50131-1 does not specify how long level 2 authorization may remain active or that it is required individually each time that level 3 acces

    15、s is required. There is thus no time limit, and level 2 authorization may remain in force until manually removed (see BS EN 50131-3:2009, 8.3.1). If level 2 authorization remains available until manually reset, written agreement is needed to confirm that the customer has agreed to this, in addition

    16、to the electronic authorization.A.4 BS EN 50131-1:2006+A1:2009, 8.8, Interconnections All conditions that allow an option of “fault” or “tamper” should be processed as “tamper” conditions (see BS EN 50131-1:2006+A.1, Table 20).Annex B (informative) UK specific guidanceB.1 Portable hold-up devices Fo

    17、r the purposes of the PD 6662 scheme, inclusion in Grades 3 and 4 of portable hold-up devices and associated receiving equipment meeting Grade 2 requirements of BS EN 50131-5-3 does not reduce the overall grade of the I&HAS.B.2 Grade 1, Option T I&HAS For the purpose of this UK scheme, it is permitt

    18、ed to install a Grade 1 I&HAS that includes an ATS with a reporting time classification of T1, provided there is always supplementary means of raising a local audible alarm. It is essential that the system complies in all other respects to all other Grade 1 requirements of BS EN 50131-1. This system is designated as Grade 1, Option T. For Grade 1, Option T systems, the supplementary warning device is located within the supervised premises inside an enclosure that has tamper detection of opening by normal means. The minimum sound output level is 70 dBA 1 metre.