欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PPT文档下载
    分享到微信 分享到微博 分享到QQ空间

    Can You Measure It-.ppt

    • 资源ID:379277       资源大小:828.50KB        全文页数:36页
    • 资源格式: PPT        下载积分:2000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要2000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Can You Measure It-.ppt

    1、,Can You Measure It?,Planning a Successful “Round Robin”,Paul Schiffelbein ASTM Committee Week14 June 2006,Overview,Measurement system analysis (Round robin, Interlaboratory Study (ILS), Interlaboratory Comparison (ILC), Gage Study) description, definitions and motivationRound robin guidelinesRound

    2、robin logisticsData AnalysisPrecision and bias statement,Purpose of Measurement System Analysis,Ensure the measurement system has adequate accuracy: precision and biasIdentify sources of measurement variation (and make improvements, if necessary)Compare several test devices, test methodologies, test

    3、 locations (linearity, bias, sensitivity)Quantify measurement variability for reference,Actual Process Variation,Measurement Variation,Observed Process Variation,Long-term Process Variation,Short-term Process Variation,Variation within a Sample,Variation due to Labs, Operators, Devices, Time,Variati

    4、on due to Gage,Bias,Linearity,“Short-term”,Stability,“Long-term”,Measurement Process Variation,Simple,“precision”,“bias”,ISO 5725-1, ASTM E177,Accuracy: The closeness of agreement between a test result and the accepted reference value“Accuracy,” when applied to a set of test results, involves a comb

    5、ination of random components and a common systematic error or bias componentBias: the difference between the expectation of test results and an accepted reference valueBias is the total systematic error as contrasted to random error. There may be one or more systematic components contributing to the

    6、 bias.,ISO 5725-1, ASTM E177,Precision: The closeness of agreement between independent test results obtained under stipulated conditions.Precision depends only on the distribution of random errors and does not relate to the true value or the specified value.Precision can be decomposed into short- an

    7、d long-term (or narrow and wide) components. Repeatability and reproducibility are used to quantify this concept.,ISO 5725-1,Repeatability: Precision under repeatability conditionsindependent test results the same test method identical test items the same laboratory the same operator the same equipm

    8、ent within short time intervalRepeatability standard deviation: The standard deviation of test results obtained under repeatability conditionsRepeatability limit (“r”): the absolute difference between two test results obtained under repeatability conditions should be less than or equal to this value

    9、,ISO 5725-1,Reproducibility: Precision under reproducibility conditionsindependent test results the same test method identical test items different laboratories different operators different equipment longer time intervalReproducibility standard deviation: The standard deviation of test results obta

    10、ined under reproducibility conditionsReproducibility limit (“R”): the absolute difference between two test results obtained under reproducibility conditions should be less than or equal to this value,Actual Process Variation,Measurement Variation,Observed Process Variation,Long-term Process Variatio

    11、n,Short-term Process Variation,Variation within a Sample,Variation due to Labs, Operators, Devices, Time,Variation due to Gage,Bias,Linearity,“Short-term” “repeatability”,Stability,“Long-term”,ASTM/ISO Usage,Simple,“reproducibility”,“bias”,Actual Process Variation,Measurement Variation,Observed Proc

    12、ess Variation,Long-term Process Variation,Short-term Process Variation,Variation within a Sample,Variation due to Labs, Operators, Devices, Time,Variation due to Gage,Bias,Linearity,“Short-term” “repeatability”,Stability,“Long-term” “reproducibility”,Gage R&R/Auto Industries Usage,Simple,“Gage”,“bia

    13、s”,Round Robin Guidelines,E 691 “Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method”D 2904 “Standard Practice for Interlaboratory Testing of a Textile Test Method that Produces Normally Distributed Data”,Round Robin Guidelines,The design should be a

    14、s simple as possible in order to obtain estimates of within- and between-laboratory variability that are free of secondary effects Study should include a minimum of five laboratories A minimum of two operators should be used per laboratory When multiple instruments within a laboratory are used, test

    15、s must be made on all equipment to establish the presence or absence of the equipment effect.,Logistics: D 885 Case Study,Motivation: The current version of D 885 was written for traditional tensile testing machines. Automated tensile testers are now being used in high-tenacity fiber testing, and ne

    16、ed to be included in this standard. The current study will include three types of automated testers, as well as parallel testing on traditional tensile test devices. The objective of this study is to quantify test precision of traditional and automated testers, as well as any bias seen between the d

    17、evice types. The study will only address aramid materials.,Logistics: D 885 Case Study,Responsibility: Task group D13.19 (Tire Cord and Fabrics) has overall responsibility of the ILS. Dawn Caullwine (chair) will act as overall coordinator for conducting the ILS. The coordinator will supervise the di

    18、stribution of materials and protocols to the laboratories and receive the test result reports from the laboratories.,Logistics: D 885 Case Study,Study Design: Nine materials will be tested on each of three types of automated tensile test devices. Two devices of each type will be used. Yarn will be s

    19、upplied in pre-twisted state for testing. Untwisted yarn will also be provided to Statimat labs, so testing can be performed both on pre-twisted yarn, and yarn automatically twisted by the test machine. Two laboratories will also test the materials using traditional methods for reference. Each of th

    20、ose laboratories will use two operators.,Logistics: D 885 Case Study,Logistics: D 885 Case Study,Materials: The ILS will include the following nine materials (All samples are shipped twisted and ready to test, except for Statimat laboratories, which receive both twisted and untwisted samples): Kevla

    21、r: 195 denier Kevlar: 600 denier Kevlar: 1140 denier Nomex: 200 denier Nomex: 1600 denier Technora: 550 denier Twaron: 840 denier Twaron: 1500 denier Twaron: 3000 denier,Logistics: D 885 Case Study,Test Determinations and Test Results: The number of test determinations required for a test result is

    22、specified in each individual test method. For the purpose of this study, each laboratory will make one hundred (100) determinations (breaks) for each material.,Logistics: D 885 Case Study,Test Determinations and Test Results: The following properties (and associated measurement units) will be record

    23、ed: Break strength (BS) N Elongation at break (EB) % Modulus between 300 mN/tex and 400 mN/tex (MOD) CN/tex FASE 0.3% N FASE 0.5% N FASE 1.0% N Use nominal linear density for modulus calculation.,Logistics: D 885 Case Study,Details: The test method being studied is D885-03. Specify the type of equip

    24、ment used, including manufacturer, model, and software program. Samples should be conditioned as per D885 7.1 to moisture equilibrium in an environmentally controlled room for a minimum of 16 hours, at RH 55 +/- 2% and temperature 24 +/- 1 degrees C (72 +/- 2 degrees F). Specific for Para-Aramid: Ga

    25、uge length: 500mm Crosshead rate: 250mm/min. (50%),Etc.,Logistics: D 885 Case Study,Data: Data should be entered into the Excel workbook provided. Label the workbook with your laboratory name, fill in the test data, and send the completed file to:Paul SchiffelbeinDuPont Engineering, Quality Manageme

    26、nt & T302/774-2417,Logistics: D 885 Case Study,Logistics: D 885 Case Study,A Better Way?: Internet Entry for F 2130 RR,Figure courtesy of Dr. Anugrah Shaw, UMES,Data Structure Guaranteed!,Logistics: D 885 Case Study,Data Analysis:,Logistics: D 885 Case Study,Data Analysis:,Repeatability and Reproduc

    27、ibility,Use between- and within-laboratory variance components:sR = s2L + s2rWhere:sR is the reproducibility standard deviation sr is the repeatability standard deviationsL is the square root of the inter-laboratory(device, operator, etc.) variance component,Logistics: D 885 Case Study,Data Analysis

    28、:,Repeatability variance,Reproducibility variance (one estimate),Reproducibility variance (another estimate),Logistics: D 885 Case Study,Precision and Bias Statement:,Logistics: D 885 Case Study,Precision and Bias Statement:,Logistics: D 885 Case Study,Precision and Bias Statement:,Logistics: D 885

    29、Case Study,Precision and Bias Statement:,Logistics: D 885 Case Study,Precision and Bias Statement:,Summary,Explicitly state objectives for your study, and make sure all participants understand them Write protocol covering responsibilities, timing, samples and sample handling, test equipment and set-up, sampling plan, properties, units, etc. Details are important! Be specific, explicit, and discuss ahead of time with task group to avoid surprises. Communicate! Set up data collection to be as “goof proof” as possible, and to facilitate subsequent analysis,Thank you,


    注意事项

    本文(Can You Measure It-.ppt)为本站会员(diecharacter305)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开