欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    ASTM C62-17 Standard Specification for Building Brick (Solid Masonry Units Made From Clay or Shale).pdf

    • 资源ID:286635       资源大小:237.70KB        全文页数:4页
    • 资源格式: PDF        下载积分:5000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要5000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    ASTM C62-17 Standard Specification for Building Brick (Solid Masonry Units Made From Clay or Shale).pdf

    1、Designation: C62 17Standard Specification forBuilding Brick (Solid Masonry Units Made From Clay orShale)1This standard is issued under the fixed designation C62; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revi

    2、sion. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This specification covers brick intended

    3、 for both struc-tural and nonstructural masonry where external appearance isnot a requirement. The brick are prismatic units available in avariety of sizes, shapes, textures, and colors. The specificationdoes not cover brick intended for use as facing units or wheresurface appearance is a requiremen

    4、t. If brick are required tohave a particular color, texture, finish, uniformity, or limits oncracks, warpage, or other imperfections detracting from theappearance they are purchased under Specification C216. Thisspecification does not cover brick intended for use as pavingbrick (see Specification C9

    5、02).1.2 The property requirements of this standard apply at thetime of purchase. The use of results from testing of brickextracted from masonry structures for determining confor-mance or nonconformance to the property requirements (Sec-tion 4) of this standard is beyond the scope of this standard.1.

    6、3 Brick are manufactured from clay, shale, or similarnaturally occurring earthy substances and subjected to a heattreatment at elevated temperatures (firing). The heat treatmentmust develop sufficient fired bond between the particulateconstituents to provide the strength and durability requirementso

    7、f this specification (see Terminology C1232).1.4 Brick are shaped during manufacture by molding,pressing, or extrusion, and the shaping method is a way todescribe the brick.1.5 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(exclu

    8、ding those in tables and figures) shall not be consideredas requirements of the standard.1.6 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered stand

    9、ard.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarrier

    10、s to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C67 Test Methods for Sampling and Testing Brick andStructural Clay TileC216 Specification for Facing Brick (Solid Masonry UnitsMade from Clay or Shale)C902 Specification for Pedestrian and Light Traffic PavingBrickC1232 Terminolog

    11、y for Masonry3. Terminology3.1 DefinitionsFor definitions relating to building brick,refer to Terminology C1232.4. Classification4.1 GradesGrades classify brick according to their resis-tance to damage by freezing and thawing when saturated at amoisture content not exceeding the 24-h cold water abso

    12、rption.Three grades of building brick are covered and the require-ments are given in Section 5.4.1.1 Grade SW (Severe Weathering)Brick intended foruse where high resistance to damage caused by cyclic freezingand thawing is desired.4.1.2 Grade MW (Moderate Weathering)Brick intendedfor use where moder

    13、ate resistance to cyclic freezing andthawing damage is permissible.1This specification is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direct responsibility of SubcommitteeC15.02 on Brick and Structural Clay Tile.Current edition approved Oct. 1, 2017. Publishe

    14、d October 2017. Originallyapproved in 1927. Last previous edition approved in 2013 as C62 13a. DOI:10.1520/C0062-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to

    15、the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with intern

    16、ationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.145 4.1.3 Grade NW (Negligible Weathering)Brick in

    17、tendedfor use where little resistance to cyclic freezing and thawingdamage is acceptable.NOTE 1The word “saturated,” with respect to this standard, refers tothe condition of a brick that has absorbed water to an amount equal to thatresulting from submersion in room temperature water for 24 h.5. Phys

    18、ical Properties5.1 DurabilityWhen Grade is not specified, the require-ments for Grade SW shall govern.5.1.1 Physical Property RequirementsThe brick shall con-form to the physical requirements for the Grade specified asprescribed in Table 1. For the compressive strength require-ments in Table 1, test

    19、 the unit with the compressive forceperpendicular to the bed surface of the unit, with the unit in thestretcher position.5.1.2 Absorption AlternateThe saturation coefficient re-quirement does not apply, provided that the 24-h cold waterabsorption of each of the five units tested does not exceed8.0 %

    20、.5.1.3 Freezing and Thawing AlternativeThe requirementsfor 5 h boiling water absorption and saturation coefficient donot apply, provided a sample of five brick, meeting the strengthrequirements of Table 1, passes the freezing and thawing test asdescribed in the Rating Section of the Freezing and Tha

    21、wingtest procedures of Test Methods C67.NOTE 2The 50 cycle freezing and thawing test is used as analternative only when the brick do not conform to either Table 1requirements for maximum water absorption and saturation coefficient, orto the requirements of the Absorption Alternate in 5.1.2.5.1.3.1 G

    22、rade SW: Breakage and Weight LossRequirementNo individual unit separates or disintegratesresulting in a weight loss greater than 0.5 % of its original dryweight.5.1.3.2 Grade SW: Cracking RequirementNo individualunit develops a crack that exceeds, in length, the units leastdimension.5.1.4 Low Weathe

    23、ring Index AlternativeIf the brick areintended for use exposed to weather where the weatheringindex is less than 50 (see Fig. 1), and unless otherwisespecified, the requirements given in Table 1 for 5 h boilingwater absorption and for saturation coefficient shall not applybut the minimum average com

    24、pressive strength requirement of2500 psi (17.2 MPa) shall apply.Grade Recommendations for Face ExposuresExposureWeathering IndexLessthan 5050 to500500 andgreaterIn vertical surfaces:In contact with earth MW or SW SW SWNot in contact with earth MW or SW SW SWIn other than vertical surfaces:In contact

    25、 with earth SW SW SWNot in contact with earth MW or SW SW SWFIG. 1 Weathering Indices in the United StatesC6217245 NOTE 3Weathering Index: The effect of weathering on brick is relatedto the weathering index, which for any locality is the product of theaverage annual number of freezing cycle days and

    26、 the average annualwinter rainfall in inches defined as follows:3A Freezing Cycle Day is any day during which the air temperaturepasses either above or below 32F (0C). The average number of freezingcycle days in a year may be taken to equal the difference between themean number of days during which

    27、the minimum temperature was 32For below and the mean number of days during which the maximumtemperature was 32F or below.Winter Rainfall is the sum, in inches, of the mean monthly correctedprecipitation (rainfall) occurring during the period between and includingthe normal date of the first killing

    28、frost in the fall and the normal date ofthe last killing frost in the spring. The winter rainfall for any period isequal to the total precipitation less one tenth of the total fall of snow, sleet,and hail. Rainfall for a portion of a month is prorated.Fig. 1 indicates general areas in the United Sta

    29、tes which correspond tothe weathering index categories listed. The index for geographic locationsnear the 50 line should be determined by an analysis of weather bureaulocal climatological summaries, with due regard to the effect of microcli-mate conditions, especially altitude.The use of Grade MW br

    30、ick in a wall area above grade is structurallyadequate in the severe weathering region, but Grade SW would provide ahigher and more uniform degree of resistance to frost action. The degreeof durability called for by Grade SW is not necessary for use in wall areasabove grade in the moderate weatherin

    31、g region. Grade MW brickperforms satisfactorily in wall areas above grade in the no-weatheringregion, where the average compressive strength of the units is at least2500 psi (17.2 MPa). Grade SW brick should be used in any region whenthe units are in contact with the ground, in horizontal surfaces,

    32、or in anyposition where they are likely to be permeated with water.The recommended correlation between grade of building brick, weath-ering index, and exposure is found in Fig. 1. The specifier can use theserecommendations or use the grade descriptions and physical requirementsalong with use exposur

    33、e and local climatological conditions to selectgrade.5.2 StrengthWhen brick are required having strengthsgreater than prescribed by this specification, the purchaser shallspecify minimum strength.5.3 Initial Rate of Absorption (IRA)Test results for initialrate of absorption (IRA) shall be determined

    34、 in accordancewith the IRA (Suction) (Laboratory Test) of Test Methods C67and shall be furnished at the request of the specifier orpurchaser. IRA is not a qualifying condition or property ofunits in this specification. This property is measured in order toassist in mortar selection and material hand

    35、ling in the construc-tion process. See Note 4.NOTE 4Initial Rate of Absorption (Suction)Both laboratory andfield investigation have shown that strong and watertight joints betweenmortar and masonry units are not achieved by ordinary constructionmethods when the units as laid have excessive initial r

    36、ates of absorption.Mortar that has stiffened somewhat because of loss of excessive mixingwater to a unit may not make complete and intimate contact with thesecond unit, resulting in poor adhesion, incomplete bond, and water-permeable joints of low strength. The IRAof the units is determined by theov

    37、en-dried procedure described in the IRA (Suction) (Laboratory Test) ofTest Methods C67. IRA in the field depends on the moisture content of themasonry unit and is determined in accordance with the IRA (Suction)Field Test of Test Methods C67. Units having average field IRAexceeding30 g/min per 30 in.

    38、2(30 g/min 194 cm2) should have their IRA reducedbelow 30 g/min per 30 in.2prior to laying. They may be wettedimmediately before they are laid, but it is preferable to wet themthoroughly 3 to 24 h prior to their use so as to allow time for moisture tobecome distributed throughout the unit.6. Dimensi

    39、ons and Permissible Variations6.1 SizeThe size of brick shall be as specified by thepurchaser. The maximum permissible variation in dimensionsof individual units shall not exceed those given in Table 2.NOTE 5Brick names denoting sizes may be regional and, therefore,may not be included in all referen

    40、ce books. Purchasers should ascertainthe size of brick available in their locality and should specify accordingly,stating the desired dimensions (width by height by length).7. Finish and Appearance7.1 The brick, as delivered to the site, shall, by visualinspection, conform to the requirements specif

    41、ied by thepurchaser or to the sample or samples approved as the standardof comparison and to the samples passing the tests for physicalrequirements. Minor indentations or surface cracks incidentalto the usual method of manufacture, or the chipping resultingfrom the customary methods of handling in s

    42、hipment anddelivery, shall not be deemed grounds for rejection.7.2 The brick shall be free of defects, deficiencies, andsurface treatments, including coatings, that would interferewith the proper setting of the brick or significantly impair thestrength or performance of the construction.7.3 Adeliver

    43、y of brick is permitted to contain not more than5 % broken brick.3Data needed to determine the weathering index for any locality may be foundor estimated from the tables of Local Climatological DataAnnual Summary withComparative Data available from the National Oceanic and Atmospheric Adminis-tratio

    44、n.TABLE 1 Physical RequirementsDesignationMinimum Compressive Strengthgross area, psi (MPa)Maximum Water Absorptionby 5-h Boiling, %Maximum SaturationCoefficientAAverage of5 BrickIndividualAverage of5 BrickIndividualAverage of5 BrickIndividualGrade SW 3000 (20.7) 2500 (17.2) 17.0 20.0 0.78 0.80Grade

    45、 MW 2500 (17.2) 2200 (15.2) 22.0 25.0 0.88 0.90Grade NW 1500 (10.3) 1250 (8.6) no limit no limit no limit no limitAThe saturation coefficient is the ratio of absorption by 24-h submersion in cold water to that after 5-h submersion in boiling water.TABLE 2 Permissible Variations in DimensionsSpecifie

    46、d dimension, in. (mm)Maximum PermissibleVariations from Spec-ified Dimension,plus or minus,in. (mm)Up to 3 (76), incl332 (2.4)Over 3 to 4 (76 to 102), incl18 (3.2)Over 4 to 6 (102 to 152), incl316 (4.8)Over 6 to 8 (152 to 203), incl14 (6.4)Over 8 to 12 (203 to 305), incl516 (7.9)Over 12 to 16 (305 t

    47、o 406), incl38 (9.5)C6217345 8. Coring and Frogging8.1 CoringUnless otherwise specified in the invitation forbids, brick shall be either solid or cored at the option of theseller. The net cross-sectional area of cored brick in any planeparallel to the surface containing the cores shall be at least75

    48、 % of the gross cross-sectional area measured in the sameplane. No part of any hole shall be less than34 in. (19.1 mm)from any edge of the brick.8.2 FroggingUnless otherwise specified in the invitationfor bids, one bearing face of each brick may have a recess orpanel frog and deep frogs. The recess

    49、or panel frog shall notexceed38 in. (9.5 mm) in depth and no part of the recess orpanel frog shall be less than34 in. (19.1 mm) from any edge ofthe brick. In brick containing deep frogs, frogs deeper than38 in. (9.5 mm), any cross-section through the deep frogsparallel to the surface containing the deep frogs shall conformto the requirements of 8.1.9. Sampling and Testing9.1 The brick shall be sampled and tested in accordancewith applicable sections in Test Methods C67.9.2 The manufacturer or the seller shall furnish specimensfo


    注意事项

    本文(ASTM C62-17 Standard Specification for Building Brick (Solid Masonry Units Made From Clay or Shale).pdf)为本站会员(卡尔)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开