1、3404583 0035433 L W Rue de Stasaart. 35 - 1050 Bruxelles TBI.: (+ 32 2) 519.68.71 - FU: (+ 32 2) 519.69.19 Teletex 208 2210087 - CENCEL - Tx 172210097 HO 22.8 Sl SHEET Reprint Issue 1 1992-05-20 May 1992 incorporating Al Rubber insulated cables of rated voltages ue to and including 450/750 V - Part
2、8: PolychJoroprene or equivalent synthetic elastomer sheathed cables for use as decorative chains Cbles sous gaine en polychloroprne ou lastomre synthtique equivalent pour guirlandes lumineuses Starkstromleitungen mit einem Mantel aus Polychloropren oder gleichwertigem synthetischem Gummi fr Lichter
3、ketten Related to Directive: 73123lEEC This Harmonization Document consists of the following: - Title Page - Text prepared by CENELEC technical committee TC 20 date of ratification : 1991-09-23 date of announcement : 1992-07-01 date of withdrawal : 1993-01-01 date of latest publication : 1993-01-01
4、LIST OF NATIONAL STANDARDS IS GIVEN OVERLEAF 3404583 0035432 3 HARMONIZED NATIONAL STANDARDS HO 22.8 S1:1992 AT : BE : CH : DE : DK : SP (SR 37-01 ES : SP (UNE 21-027-8 (1991) FI : FR : GE : GR : IE : IS : IST L 104:1991 IT : CE1 20-19 (19901 LU : NOS NC : NO : - PT : SE : NOS No standard SP Standar
5、d in preparation NR Standard under revision HARMONIZATION DOCUMENT - HD 22.8 si DOCUMENT DHARMONISATION Reprint incorporating AI HARMONISIERUNGSDOKUMENT May 1992 UDC 621.31 5.2:621.315.616:628.974.6 Descriptors: Electrical Installation, insulated de, outer sheath, rubber, lighting chain English vers
6、ion Rubber insulated cables of rated voltages up to and including 450/750 V Part 8: Polychloroprene or equivalent synthetic elastomer sheathed cables for use as decorative chains Conducteurs de cbles isols au caoutchouc de tension assigne au plus gale 450/750 V Huitime partie: Cbles sous gaine en po
7、lychloroprne ou lastomre synthtique quivalent pour guirlandes lumineuses fr Lichterketten Isolierte Starkstromleitungen mit einer Isolierung aus Gummi mit Nennspannungen bis 450/750 V Teil 8: Starkstromleitungen mit einem Mantel aus Polychloropren oder gleichwertigem synthetischem Gummi This Harmoni
8、zation Document was approved by CENELEC on 23 September 1991. CENELEC members are bound to comply with the CEWCENELEC Internal Regulations which stipulate the conditions for implementation of this Harmonization Document on a national level. Up-to-date lists and bibliographical references concerning
9、national implementation may be obtained on application to the Central Secretariat or to any CENELEC member. This Harmonization Document exists in three officiai versions (English, French, German). CENELEC members are the national electrotechnicai committees of Austria, Belgium, Denmark, Finland, Fra
10、nce, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Swiizerand and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Cen
11、tral Secretariat: rue de Stassart 35, B - 1050 Brussels P O 1992 Copyright reserved to CENELEC members Ref. No. HD 22.8 S1:1992 E W 3404583 0035434 7 i. Page 2 HD22.8 S1 - REPRINT FOR E WORD HD22 was originally adopted by CENELEC on 9th July 1975, Edition 2 of HD22 was implemented on 1 st January 19
12、84, and at that time contained 4 parts, Since 1984, new parts have been published, original parts amended, and in addition HD 505 has superseded HD 385 as the cross-reference for test methods. The reprint of the 4 parts of Edition 2 of HD22 incorporates all ratified amendments and the change to HD 5
13、05. The new parts of HD22, which are Edition 1 versions, already incorporate the change to HD 505 and are being updated as appropriate. HD22 now has the following parts: HD22.1 S2 - HD22.2S2 - HD22.3 S2 - HD22.4S2 - HD22.6 S1 - HD22.7 S1 - HD22.5 - HD22.8 S1 - General requirements (with AM1 to AM101
14、 Test methods (with AM1 to AM4) Heat resistant silicone rubber insulated cables (with AM1 1 Cords and flexible cables (with AM1 to AM51 (Spare) Arc welding cables Cables with increased heat resistance for internal wiring for a conductor temperature of 1 10% Polychloroprene or equivalent synthetic el
15、astomer sheathed cable for use as decorative chains (with AM1 1 . This Edition 1 of part 8 of HD22 now incorporates: AM1 - dop 1993-01-01 In accordance with the guidance given by CENELEC the dop for this Reprint is 1993-01-01. References are made, in this Part 8 of HD22, to other Parts of this HD an
16、d to other Harmonisation Documents as follows: HD 383 Conductors of insulated cables (Endorsing IEC 228 and 228A) HD 405.1 Tests on electric cables under fire conditions. Part 1: Test on a single vertical cable (Endorsing IEC 332-1 1 HD 505 Common test methods for insulating and sheathing materials
17、of electric cables (Endorsing IEC 81 1) In all cases a reference to another HD implies the latest edition of that document. e 1, Scope Page 3 HD22.8 S1 - REPRINT 1992 CONTENTS Page 2. Polychloroprene or equivalent synthetic elastomer sheathed cable for decorative chains 2.1 Code designation 2.2 Rate
18、d voltage 2.3 Construction 2.4 Tests 2.5 Guide to use 4 e 3404583 003543b O Page 4 * HD22.8 S1 - REPRINT RUBBER INSULATED CABLES OF RATED VOLTAGE UP TO AND INCLUDING 450/750V PART 8 : POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLE FOR DECORATIVE CHAINS Scorie This Part 8 of the HD
19、details the particular requirements for rubber insulated, polychloroprene, or other equivalent synthetic elastomer, sheathed cable of rated voltage Uo/U 300/500V for use as decorative chains. Each cable shall comply with the appropriate requirements given in Part 1 of this HD and the particular requ
20、irements of this Part. Polvchlorowene or Eauivalent Svnthetic Elastomer Sheathed Cable For Decorative Chains 2.1 2.2 2.3 Code desianation H05RN-F for single core cables H05RNH2-F for flat two core cables Rated voltaae 300/500V Construction 2.3.1 Conductor Number of Conductors: 1 or 2 The conductors
21、shall comply with the requirements given in HD 383 for Class 5 conductors. The wires may be plain or tinned. 2.3.2 Separator A separator of suitable materiai may be applied around each conductor. 2.3.3 Insulation , The insulation shall be rubber compound of the type Ei4 applied around each conductor
22、. The insulation shall be applied by extrusion. The insulation thickness shall comply with the specified value given in Table I, column 2 of this Part. 2.3.4 Assembly of cores The cores of the two core cables shall be laid in parallel. The distance between the centre of conductors shall comply with
23、the mean values given in Table I, columns 3 and 4 of this Part, Page 5 HD22.8 S1 - REPRINT 1992 2.3,5 Sheath The sheath shall be rubber compound of type EM2 applied around the core. The sheath shall be applied as follows:- (a) for single core cables The sheath shall be capable of being removed witho
24、ut damage to the cores. (b) for two core cables The sheath shall fill the spaces between the cores forming a filling but it shall be capable of being removed without damage to the cores. The thickness of the sheath shall comply with the specified value given in Table I, column 5 of this Part. The pr
25、eferred sheath colours are green or black. 2.3.6 Overall dimensions The mean overall dimensions shall be within the limits given in Table I, columns 6 and 7 of this Part. 2.3.7 Core identification Each core shall be identified by colour as follows:- single core cable: brown two core cable : brown an
26、d light blue Compliance with the requirements of Clause 2.3 of this Part shall be checked by inspection and by the tests given in Table II of this Part. For the requirements of Clause 2.3.4, the procedure to be followed is generally as specified in Clause 1.1 1 of Part 2 of this HD except that the m
27、easured value is the distance between the centres of the two conductors. The mean of the values obtained from the three samples shall be taken as the mean distance. 2.5 Guide to use See Appendix 1 to Part 1 of this HD. 3VOV583 0035438 4 E * Page 6 HD22.8 S1 - REPRINT Table I, General Data for TvDes
28、H05RN-F AND HO5RNH2-F 1 Number and Nominal cross- cecjional area of conductors mm2 1 x 0.75 1 x 1-0 1 x 1.5 2 x 1.5 2 x 2.5 2 Thickness of insulation specified value mm 0.8 0.8 0.8 0.8 0.8 3 Distance centres of mean lower limit mm 6,7 6.7 4 between :onductors mean upper limit mm 7,O 7.0 5 Thickness
29、of sheath specified value mm 0.8 0.8 0.8 o,a 0.8 617 Mean overall dimensions lower limit upper limit I mm I mm 5.4 5.8 6.2 5.0 x 13,O I 6.0 x 14.0 5a0 x 13.0 6.0 x 14.0 - I 3404583 0035439 b I 1 Ref, NO. 1. 1.1 1.2 1.3 1.4 1.5 2. 2.1 2.2 2.3 2.4 2.4.1 2,4.2 2.4.3 3. 3.1 3.2 3.3 3.4 3.5 4. 4,l 4.2 4.
30、3 4.4 5. 5.1 6. Page 7 HD22.8 S1 - REPRINT 1992 Table II Tests for TvDes H05RN-F and H05RNH2-F 2 Test _ Electrical Tests Resistance of conductors Voltage test on cores at 2000V Voltage test on completed cable at 2000v Absence of faults in insulation Surface insulation resistance of sheath Provisions
31、 coverino constructional and dimensional characteristics Checking of compliance with constructional provisions Mesurement of thickness of insulation Measurement of sheath thickness Measurement of overall dimensions Mean Value Ovality Distance between centres of conductors Mechanical woDerties of ins
32、ulation Tensile test before ageing Tensile test after ageing in the air oven Tensile test after ageing in the oxygen bomb Hot set test Ozone resistance test Mechanical DroDerties of sheath Tensile test before ageing Tensile test after ageing in the air oven Tensile test after immersion in oil Hot se
33、t test Mechanical strenath of cornoleted cable Flexing test for multicore cables Test under fire conditions 3 Category 41 5 Test Method described in: HD 22.2 22.2 22.2 22.2 22.2 22.1 22.2 22.2 22.2 22.8 505.1.1 505.1.2 505.1.2 505.2.1 22.2 505.1.1 505.1.2 505.2.1 505.2.1 22.2 405.1 Clause 2.1 2.3 2.2 2.6 2.7 Inspection and manual tests 1.9 1 .lo 1.11 2.4 9.1 8.1 8.3 9 7 9.2 8.1 10 9 3.1 P