1、BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Specification for radio disturbance and immunity measuring apparatus and methodsPart 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurementsBS EN 55016-2-3:2017EUROPEAN STANDARD NORM
2、E EUROPENNE EUROPISCHE NORM EN 55016-2-3 April 2017 ICS 33.100.10; 33.100.20 Supersedes EN 55016-2-3:2010 English Version Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measuremen
3、ts (CISPR 16-2-3:2016) Spcifications des mthodes et des appareils de mesure des perturbations radiolectriques et de limmunit aux perturbations radiolectriques - Partie 2-3: Mthodes de mesure des perturbations et de limmunit - Mesures des perturbations rayonnes (CISPR 16-2-3:2016) Anforderungen an Ge
4、rte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Straussendung (Funkstrungen) und Strfestigkeit - Teil 2-3: Verfahren zur Messung der hochfrequenten Straussendung (Funkstrungen) und Strfestigkeit - Messung der gestrahlten Straussendung (CISPR 16-2-3:2016) This Euro
5、pean Standard was approved by CENELEC on 2016-10-20. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical reference
6、s concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN
7、ELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugosla
8、v Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical
9、 Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN
10、55016-2-3:2017 E National forewordThis British Standard is the UK implementation of EN 55016-2-3:2017. It is identical to CISPR 16-2-3:2016. It supersedes BS EN 55016-2-3:2010+A2:2014, which will be withdrawn on 20 October 2019.The UK participation in its preparation was entrusted to Technical Commi
11、ttee GEL/210/11, EMC - Standards Committee.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standar
12、ds Institution 2018 Published by BSI Standards Limited 2018ISBN 978 0 580 85583 2ICS 33.100.20; 33.100.10Compliance with a British Standard cannot confer immunity from legal obligations. This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 Janu
13、ary 2018.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 55016-2-3:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 55016-2-3 April 2017 ICS 33.100.10; 33.100.20 Supersedes EN 55016-2-3:2010 English Version Specification for radio disturbance and immunit
14、y measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements (CISPR 16-2-3:2016) Spcifications des mthodes et des appareils de mesure des perturbations radiolectriques et de limmunit aux perturbations radiolectriques - Partie 2
15、-3: Mthodes de mesure des perturbations et de limmunit - Mesures des perturbations rayonnes (CISPR 16-2-3:2016) Anforderungen an Gerte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Straussendung (Funkstrungen) und Strfestigkeit - Teil 2-3: Verfahren zur Messung der
16、hochfrequenten Straussendung (Funkstrungen) und Strfestigkeit - Messung der gestrahlten Straussendung (CISPR 16-2-3:2016) This European Standard was approved by CENELEC on 2016-10-20. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giv
17、ing this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three
18、 official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electr
19、otechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Roma
20、nia, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000
21、 Brussels 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 55016-2-3:2017 E BS EN 55016-2-3:2017EN 55016-2-3:2017 European foreword The text of document CISPR/A/1176A/FDIS, future edition 4 of CISPR 16-2-3, prepared by CISPR SC
22、A “Radio-Interference measurements and statistical methods“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 55016-2-3:2017. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national st
23、andard or by endorsement (dop) 2017-10-28 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2020-04-28 This document supersedes EN 55016-2-3:2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of
24、 patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard CISPR 16-2-3:2016 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliograp
25、hy, the following notes have to be added for the standards indicated: CISPR 11:2015 NOTE Harmonized as EN 55011:2016. CISPR 16-1-6:2014 NOTE Harmonized as EN 55016-1-6:2015. CISPR 22:2008 NOTE Harmonized as EN 55022:2010. IEC 61140:2016 NOTE Harmonized as EN 61140:2016. ISO/IEC Guide 2:2004 NOTE Har
26、monized as EN 45020:2006. ISO/IEC 17000:2004 NOTE Harmonized as EN ISO/IEC 17000:2004. IEC 61000-4-21 NOTE Harmonized as EN 61000-4-21. BS EN 55016-2-3:2017EN 55016-2-3:2017 Annex ZA (normative) Normative references to international publications with their corresponding European publications The fol
27、lowing documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an
28、 International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 60050-161
29、 - International Electrotechnical Vocabulary (IEV) - Chapter 161: Electromagnetic compatibility - - IEC 61000-4-3 2006 Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test EN 61000-4-3 2006 + A1 2007 + A1
30、2008 + A2 2010 + A2 2010 IEC 61000-4-20 - Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides EN 61000-4-20 CISPR 14-1 2016 Electromagnetic compatibility - Requirements for household applia
31、nces, electric tools and similar apparatus - Part 1: Emission FprEN 55014-1 2016 CISPR 16-1-1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring appartus - - CISPR 16-1-2 2014 Specification for
32、 radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements EN 55016-1-2 2014 CISPR 16-1-4 2010 Specification for radio disturbance and immunity measuring apparatus and method
33、s - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements EN 55016-1-4 2010 + A1 2012 + A1 2012 CISPR 16-2-1 2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement
34、 of disturbances and immunity - Conducted disturbance measurements EN 55016-2-1 2014 CISPR 16-4-2 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty EN 55016-4-2 BS EN
35、55016-2-3:2017EN 55016-2-3:2017 CISPR TR 16-4-1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests - - CISPR TR 16-4-5 - Specification for radio disturbance and immunit
36、y measuring apparatus and methods - Part 4-5: Uncertainties, statistics and limit modelling - Conditions for the use of alternative test methods - - BS EN 55016-2-3:2017 2 CISPR 16-2-3:2016 IEC 2016 CONTENTS FOREWORD. 7 1 Scope 9 2 Normative references 9 3 Terms, definitions and abbreviations 10 3.1
37、 Terms and definitions 10 3.2 Abbreviated terms . 15 4 Types of disturbance to be measured . 16 4.1 General . 16 4.2 Types of disturbance . 16 4.3 Detector functions . 16 5 Connection of measuring equipment 16 6 General measurement requirements and conditions 17 6.1 General . 17 6.2 Disturbance not
38、produced by the equipment under test 17 6.2.1 General 17 6.2.2 Compliance (conformity assessment) testing . 17 6.3 Measurement of continuous disturbance 17 6.3.1 Narrowband continuous disturbance . 17 6.3.2 Broadband continuous disturbance . 17 6.3.3 Use of spectrum analyzers and scanning receivers
39、. 17 6.4 EUT arrangement and measurement conditions . 18 6.4.1 General arrangement of the EUT 18 6.4.2 Operation of the EUT . 20 6.4.3 EUT time of operation 20 6.4.4 EUT running-in time . 21 6.4.5 EUT supply 21 6.4.6 EUT mode of operation . 21 6.4.7 Operation of multifunction equipment 21 6.4.8 Dete
40、rmination of arrangement(s) causing maximum emissions 21 6.4.9 Recording of measurements . 21 6.5 Interpretation of measuring results 22 6.5.1 Continuous disturbance 22 6.5.2 Discontinuous disturbance 22 6.5.3 Measurement of the duration of disturbance 22 6.6 Measurement times and scan rates for con
41、tinuous disturbance 22 6.6.1 General 22 6.6.2 Minimum measurement times . 23 6.6.3 Scan rates for scanning receivers and spectrum analyzers 23 6.6.4 Scan times for stepping receivers . 24 6.6.5 Strategies for obtaining a spectrum overview using the peak detector 25 6.6.6 Timing considerations using
42、FFT-based instruments . 29 7 Measurement of radiated disturbances . 32 7.1 Introductory remarks . 32 7.2 Loop-antenna system measurements (9 kHz to 30 MHz) 33 7.2.1 General 33 7.2.2 General measurement method 33 BS EN 55016-2-3:2017CISPR 16-2-3:2016 IEC 2016 3 7.2.3 Test environment . 34 7.2.4 Confi
43、guration of the equipment under test . 35 7.2.5 Measurement uncertainty for LAS . 35 7.3 Open-area test site or semi-anechoic chamber measurements (30 MHz to 1 GHz) 35 7.3.1 Measurand . 35 7.3.2 Test site requirements 38 7.3.3 General measurement method 38 7.3.4 Measurement distance . 39 7.3.5 Anten
44、na height variation . 40 7.3.6 Product specification details . 40 7.3.7 Measurement instrumentation . 42 7.3.8 Field-strength measurements on other outdoor sites . 42 7.3.9 Measurement uncertainty for OATS and SAC 42 7.4 Fully-anechoic room measurements (30 MHz to 1 GHz) . 42 7.4.1 Test set-up and s
45、ite geometry 42 7.4.2 EUT position 45 7.4.3 Cable layout and termination 46 7.4.4 Measurement uncertainty for FAR . 47 7.5 Radiated emission measurement method (30 MHz to 1 GHz) and radiated immunity test method (80 MHz to 1 GHz) with common test set-up in semi-anechoic chamber . 47 7.5.1 Applicabil
46、ity . 47 7.5.2 EUT perimeter definition and antenna-to-EUT separation distance 47 7.5.3 Uniform test volume . 48 7.5.4 Specifications for EUT set-up in common emissions/immunity test set-up 49 7.5.5 Measurement uncertainty for common emission/immunity set-up and method 55 7.6 Fully-anechoic room and
47、 absorber-lined OATS/SAC measurements (1 GHz to 18 GHz) 55 7.6.1 Quantity to measure . 55 7.6.2 Measurement distance . 55 7.6.3 Set-up and operating conditions of the equipment under test (EUT) . 56 7.6.4 Measurement site . 56 7.6.5 Measurement instrumentation . 56 7.6.6 Measurement procedure . 57 7
48、.6.7 Measurement uncertainty for FAR . 63 7.7 In situ measurements (9 kHz to 18 GHz) 64 7.7.1 Applicability of and preparation for in situ measurements 64 7.7.2 Field-strength measurements in situ in the frequency range 9 kHz to 30 MHz 65 7.7.3 Field-strength measurements in situ in the frequency ra
49、nge above 30 MHz 65 7.7.4 In situ measurement of the disturbance effective radiated power using the substitution method 66 7.7.5 Documentation of the measurement results . 70 7.7.6 Measurement uncertainty for in situ method 70 7.8 Substitution measurements (30 MHz to 18 GHz) 70 7.8.1 General 70 7.8.2 Test site . 71 BS EN 55016-2-3:2017 4 CISPR 16-2-3:2016 IEC 2016 7.8.3 Test antennas 71 7.8.4 EUT configuration 72 7.8.5 Test procedure . 72 7.8.6 Measurement uncertainty for substitution method