1、BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Alarm systems Intrusion and hold-up systemsPart 6: Power suppliesBS EN 501316:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 50131-6 October 2017 ICS 13.310 Supersedes EN 50131-6:2008English Version Alarm syst
2、ems - Intrusion and hold-up systems - Part 6: Power supplies Systmes dalarme - Systmes dalarme contre lintrusion et les hold-up - Partie 6: Alimentation Alarmanlagen - Einbruch- und berfallmeldeanlagen - Teil 6: Energieversorgungen This European Standard was approved by CENELEC on 2017-09-18. CENELE
3、C members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on appl
4、ication to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CE
5、NELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, I
6、celand, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechn
7、ique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 50131-6:2017 ENational forewordThis British Standard is the
8、UK implementation of EN 501316:2017. It supersedes BS EN 501316:2008+A1:2014, which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee GW/1/1, Alarm components.A list of organizations represented on this committee can be obtained on request to its secretary.Thi
9、s publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2018 Published by BSI Standards Limited 2018ISBN 978 0 580 86347 9ICS 13.310Compliance with a British Standard cannot confer immu
10、nity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 February 2018.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 501316:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN
11、 50131-6 October 2017 ICS 13.310 Supersedes EN 50131-6:2008English Version Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies Systmes dalarme - Systmes dalarme contre lintrusion et les hold-up - Partie 6: Alimentation Alarmanlagen - Einbruch- und berfallmeldeanlagen - Teil 6: Ene
12、rgieversorgungen This European Standard was approved by CENELEC on 2017-09-18. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and
13、bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under th
14、e responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia
15、, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Commi
16、ttee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENE
17、LEC Members. Ref. No. EN 50131-6:2017 EBS EN 501316:2017EN 50131-6:2017 (E) 2 Contents Page European foreword . 4 Introduction . 5 1 Scope . 6 2 Normative references. 6 3 Terms, definitions and abbreviations 7 3.1 Terms and definitions 7 3.2 Abbreviations . 9 4 Functional requirements . 9 4.1 PS con
18、figurations . 9 4.2 General requirements 10 4.3 Monitoring of PS .13 4.4 APS capability 17 4.5 Recharging for PS Type A .17 4.6 Over-voltage protection .18 4.7 Short circuit protection18 4.8 Overload protection .18 4.9 Deep discharge protection 18 4.10 Ripple 18 4.11 Tamper security 18 4.12 Environm
19、ental 21 4.13 Safety .22 4.14 EMC susceptibility .22 4.15 Electrical .22 5 Marking 23 6 Documentation .23 7 Tests 24 7.1 General 24 7.2 General test conditions .25 7.3 Reduced functional test 26 7.4 Monitoring: Loss of EPS .26 7.5 Monitoring: Storage Device Low Residual Energy .27 7.6 Monitoring: St
20、orage Device Failure 30 7.7 Monitoring: Low Output Voltage 30 7.8 Monitoring: Power Unit Failure Loss of PU Power Output .31 BS EN 501316:2017EN 50131-6:2017 (E) 3 7.9 Monitoring: Power Unit Failure Loss of SD Recharge 32 7.10 Test on demand 32 7.11 APS Capability 33 7.12 Recharging for PS Type A .3
21、4 7.13 Over voltage protection .35 7.14 Short Circuit Protection .36 7.15 Overload Protection .37 7.16 Deep Discharge Protection .38 7.17 Tamper security - Protection 39 7.18 Tamper Detection Access to inside of the housing 39 7.19 Tamper detection Removal from mounting 40 7.20 Tamper detection Pene
22、tration of the housing .41 7.21 Environmental and EMC 42 7.22 PS Rating 42 7.23 Output voltage stability - Gradual load variation 45 7.24 Output Voltage Stability Switched Load Variation 46 7.25 Marking and Documentation .47 Annex A (informative) Determination of Storage Device failure 48 Annex B (n
23、ormative) Measurement of ripple voltage .49 B.1 General 49 B.2 Principle 49 B.3 Test conditions .49 B.4 Measurement 49 B.5 Pass/Fail Criteria 49 Annex C (normative) Measurement of transients 50 C.1 General 50 C.2 Principle 50 C.3 Test conditions .50 C.4 Measurement 50 C.5 Pass/Fail Criteria 50 Annex
24、 D (informative) Test on Demand signal or message timing and usage protocol .51 Annex E (informative) Cross-reference between requirements and corresponding tests .52 BS EN 501316:2017EN 50131-6:2017 (E) 4 European foreword This document (EN 50131-6:2017) has been prepared by CLC/TC 79 “Alarm system
25、s”. The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2018-09-18 latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2020
26、-09-18 This document supersedes EN 50131-6:2008. The revision is to make the document less technology specific and more inclusive of the different types of power supplies found in I and b) optional functions which may be provided. This European Standard does not deal with requirements for compliance
27、 with EC regulatory Directives, such as the EMC Directive, Low Voltage Directive, etc. except that it specifies the equipment operating conditions and reduced functional test for EMC susceptibility testing as required by EN 50130-4. Other functions associated with I (ii) integrated with at least one
28、 other I (iii) integrated with at least one other I Fig. 1 a) Standalone PS PS Independent Power Outputs to I the PPPS is the normal continuously available external source of power for the I the SPPS provides an external back-up source of power in the event of loss of PPPS, for example a standby gen
29、erator; there is no requirement for the I an alternative power source provides a back-up source of power to the I the APS is derived from a SD which is housed within the PS. NOTE 1 The PPPS may be a local source of power, for example a generator, with the SPPS provided by the public mains electricit
30、y supply. NOTE 2 The EPS may have a voltage and frequency other than that of the public mains electricity supply, for example as provided from a low voltage battery bank. For PS type C, the prime power source is derived from a SD which is housed within the PS. A PS type A shall recharge the SD autom
31、atically from the EPS when the EPS is present, and maintain it in a charged state. NOTE There is no requirement for the charging to be continuous to maintain the SD in its charged state. Where the SD in a PS type B is rechargeable, recharging of the SD shall be from an energy source other than the E
32、PS. This energy source may be non-continuous, e.g. derived from solar radiation. A fault on one independent power output of a PS will have no impact upon the functionality of any other independent power output. Each independent power output may have provision for more than one connection. BS EN 5013
33、16:2017EN 50131-6:2017 (E) 12 Figure 2 Power Supply Types PU SD PS Independent power outputs to I and BS EN 501316:2017EN 50131-6:2017 (E) 23 b) no more than 140 % of the maximum power output voltage and no less than 75 % of the minimum power output voltage for a period not exceeding 1 ms. 5 Marking
34、 The PS shall be marked in accordance with EN 50131-1. 6 Documentation The PS shall be accompanied by documentation in accordance with EN 50131-1. Additionally, the documentation shall contain the following information: a) installation, commissioning, maintenance and operating instructions; b) brief
35、 description of operation including characteristics of monitoring functions provided; c) PS type (i.e. A, B or C); d) for PS types A and B, voltage rating and frequency (where applicable) requirements of the EPS; e) rated output of the PS and maximum rated output of each independent power output; f)
36、 any limitation on the characteristics of the load that may be connected to the PS; g) the power requirement for any integrated component, e.g. CIE, or the PS control circuitry; h) output voltage range under normal operating conditions; i) for PS with dc outputs, the maximum output peak to peak ripp
37、le voltage; j) type of SD, and the minimum and maximum SD capacity that can be used with the PS; k) maximum time to recharge a SD of maximum capacity to 80 % of its rated capacity; l) the SD criteria at which the SD Low Residual Energy signal or message will be generated; m) the voltage at each inde
38、pendent power output below which the Power Output Fault signal or message will be generated; n) the SD criteria at which the Deep Discharge Protection function will operate; o) over voltage protection trigger voltage; p) connection details, including sufficient detail to enable effective interface a
39、nd operation as part of the I q) electrical and logical characteristics of monitoring signals and messages, e.g. volt-free contact, message protocols supported, response to Test On Demand request; r) operating temperature and humidity range; s) weights and dimensions; t) fixing details; u) details o
40、f type and value for any user serviceable components, e.g. fuses; BS EN 501316:2017EN 50131-6:2017 (E) 24 v) details (e.g. frequency and procedure) of any required calibration checks and adjustments; w) whether or not the PS is suitable for use external to the supervised premises (see 4.11.2 and 4.1
41、1.3); x) where applicable for PS type A, the SD criteria at which the SD will not be automatically recharged on reconnection of the EPS; y) minimum energy level of the SD in its charged state (as a percentage of the SD rated capacity for the range of SDs that can be used with the PS). 7 Tests 7.1 Ge
42、neral Where products are to be tested for compliance with this standard, the following tests shall be applied to PS types A, B and C according to Table 10 for the appropriate grade as defined in Table 1. These tests are intended to be primarily concerned with verifying the correct operation of the P
43、S to the requirements of this standard and the specification provided by the manufacturer. All the test parameters specified shall carry a general tolerance of 10 % unless otherwise stated. Table 10 Tests for PS according to Type Test Title Test No. Type A Type B Type C 1 Reduced Functional Test 7.3
44、 M M M 2 Monitoring: Loss of EPS 7.4 M M N/A 3 Monitoring: Storage Device Low Residual Energy 7.5 M M M 4 Monitoring: Storage Device Failure 7.6 M N/A N/A 5 Monitoring: Low Output Voltage 7.7 M M N/A 6 Monitoring: Power Unit Failure - Loss of PU Power Output 7.8 M M N/A 7 Monitoring: Power Unit Fail
45、ure Loss of SD Recharge 7.9 M N/A N/A 8 Test on Demand Request 7.10 M N/A N/A 9 APS Capability 7.11 M M N/A 10 Recharging for PS Type A 7.12 M N/A N/A 11 Over-voltage Protection 7.13 M M N/A 12 Short Circuit Protection 7.14 M M M 13 Overload Protection 7.15 M M M 14 Deep Discharge Protection 7.16 M
46、M M 15 Tamper Protection 7.17 M M M 16 Tamper Detection Access to inside of the housing 7.18 M M M BS EN 501316:2017EN 50131-6:2017 (E) 25 Test Title Test No. Type A Type B Type C 17 Tamper Detection Removal from Mounting 7.19 M M M 18 Tamper Detection Penetration of Housing 7.20 M M M 19 Environmen
47、tal and EMC 7.21 M M M 20 PS Rating 7.22 M M M 21 Output Voltage Stability Gradual Load variation 7.23 M M M 22 Output Voltage Stability Switched Load variation 7.24 M M M 23 Marking and Documentation 7.25 M M M M = Test mandatory for PS Type N/A = Not Applicable 7.2 General test conditions 7.2.1 St
48、andard laboratory conditions for testing The general atmospheric conditions in the measurement and tests laboratory shall follow the requirements below, unless stated otherwise: Temperature: 15 C to 35 C Relative humidity: 25 % RH to 75 % RH Air pressure: 86 kPa to 106 kPa 7.2.2 General detection te
49、sting environment and procedures The PS manufacturers documented instructions regarding mounting and operation shall be applied to all tests. 7.2.3 Signal or message processing time Where the PS is integrated with another I b) is generated within the specified time periods when the EPS is removed; c) is removed within the specified time period when the EPS is re-connected. 7.4.2 Test conditions Ensure the PS is loaded to at least 10 % of its rated output. 7.4.3 Mounting Mount the PS according to the PS m