1、 ISO/IEC/TR 29106 Edition 1.0 2012-12 TECHNICAL REPORT Information technology Generic cabling Introduction to the MICE environmental classification ISO/IEC/TR 29106:2007/A1:2012(E) AMENDMENT 1 THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2012 ISO/IEC, Geneva, Switzerland All rights reserved. Un
2、less otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in the country of the requester. If you hav
3、e any questions about ISO/IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. IEC Central Office Tel.: +41 22 919 02 11 3, rue de Varemb Fax: +41 22 919 03 00 CH-
4、1211 Geneva 20 infoiec.ch Switzerland www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical cont
5、ent of IEC publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Useful links: IEC publications search - www.iec.ch/searchpub The advanced search enables you to find IEC publications by a vari
6、ety of criteria (reference number, text, technical committee,). It also gives information on projects, replaced and withdrawn publications. IEC Just Published - webstore.iec.ch/justpublished Stay up to date on all new IEC publications. Just Published details all new publications released. Available
7、on-line and also once a month by email. Electropedia - www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 30 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known as the International
8、Electrotechnical Vocabulary (IEV) on-line. Customer Service Centre - webstore.iec.ch/csc If you wish to give us your feedback on this publication or need further assistance, please contact the Customer Service Centre: csciec.ch. ISO/IEC/TR 29106 Edition 1.0 2012-12 TECHNICAL REPORT Information techn
9、ology Generic cabling Introduction to the MICE environmental classification INTERNATIONAL ELECTROTECHNICAL COMMISSION A ICS 35.200 PRICE CODE ISBN 978-2-83220-543-3 AMENDMENT 1 Warning! Make sure that you obtained this publication from an authorized distributor. 2 TR 29106 Amend.1 ISO/IEC:2012(E) FO
10、REWORD Amendment 1 to Technical Report ISO/IEC TR 29106 was prepared by subcommittee 25: Interconnection of information technology equipment, of ISO/IEC joint technical committee 1: Information technology. This Amendment 1 has been approved by vote of the member bodies, and the voting results may be
11、 obtained from the address given on the second title page. _ INTRODUCTION to Amendment 1 This Amendment has been developed to correct the misalignment of the MICE table with ISO/IEC 24702. 2 Reference documents Delete the following two references. IEC 61000-2-5, Electromagnetic compatibility (EMC) P
12、art 2: Environment Section 5: Classification of electromagnetic environments. Basic EMC publication IEC 61326:2001, Electrical equipment for measurement, control and laboratory use EMC requirements 5.5 Electromagnetic environment Replace existing Table 6 by the following new Table 6. NOTE The update
13、d references have been indicated by grey areas. TR 29106 Amend.1 ISO/IEC:2012(E) 3 Table 6 Derivation of boundaries for electromagnetic criteria in Table 1 Electromagnetic E 1E 2E 3Electrostatic discharge Contact (0,667 C) 4 kV 4 kV 4 kV Electrostatic discharge Air (0,132 C) 8 kV 8 kV 8 kV IEC 61000
14、-6-1 and IEC 61000-6-2 Radiated RF AM 3 V/m at 80 MHz to 1 000 MHz 3 V/m at 1 400 MHz to 2 000 MHz 1 V/m at 2 000 MHz to 2 700 MHz 3 V/m at 80 MHz to 1 000 MHz 3 V/m at 1 400 MHz to 2 000 MHz 1 V/m at 2 000 MHz to 2 700 MHz 10 V/m at 80 MHz to 1 000 MHz 3 V/m at 1 400 MHz to 2 000 MHz 1 V/m at 2 000
15、 MHz to 2 700 MHz IEC 61000-6-1 IEC 61000-6-2 Conducted RF 3 V at 150 kHz to 80 MHz 3 V at 150 kHz to 80 MHz 10 V at 150 kHz to 80 MHz IEC 61000-6-1 IEC 61000-6-2 EFT/B (comms) 500 V 500 V 1 000 V IEC 61000-6-1 IEC 61000-6-2 Surge (transient ground potential difference) - signal, line to earth 500 V
16、 1 000 V 1 000 V IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-2 Magnetic field (50/60 Hz) 1 Am 13 Am 130 Am 1 IEC 61000-6-1 IEC 61000-6-2 Magnetic field (60 Hz to 20 000 Hz) ffs ffs ffs _ INTERNATIONAL ELECTROTECHNICAL COMMISSION 3, rue de Varemb PO Box 131 CH-1211 Geneva 20 Switzerland Tel: + 41 22 919 02 11 Fax: + 41 22 919 03 00 infoiec.ch www.iec.ch