1、 Reference numberISO 15996:2005/Amd.1:2007(E)ISO 2007INTERNATIONAL STANDARD ISO15996First edition2005-04-01AMENDMENT 12007-12-01Gas cylinders Residual pressure valves General requirements and type testing AMENDMENT 1 Bouteilles gaz Robinets pression rsiduelle Exigences gnrales et essais de type AMEN
2、DEMENT 1 ISO 15996:2005/Amd.1:2007(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing t
3、he editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file
4、can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretar
5、iat at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2007 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing
6、from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2007 All rights reservedISO 15996:2005
7、/Amd.1:2007(E) ISO 2007 All rights reserved iiiForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each me
8、mber body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International E
9、lectrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards ad
10、opted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of pa
11、tent rights. ISO shall not be held responsible for identifying any or all such patent rights. Amendment 1 to ISO 15996:2005 was prepared by Technical Committee ISO/TC 58, Gas cylinders, Subcommittee SC 2, Cylinder fittings. ISO 15996:2005/Amd.1:2007(E) ISO 2007 All rights reserved 1Gas cylinders Res
12、idual pressure valves General requirements and type testing AMENDMENT 1 Page 1, Clause 2, Normative references Replace the reference “ISO 10297:1999, Gas cylinders Refillable gas cylinder valves Specification and type testing” with the reference “ISO 10297, Transportable gas cylinders Cylinder valve
13、s Specification and type testing”. Page 12, Annex C Replace the entire text of Annex C with the following: “The residual pressure function of the valve should resist leakage of gas due to vibration experienced in transport. The following test is given as an example of how to reproduce the vibration
14、during transportation. The test shall be carried out with a minimum of 3 samples (at least 1 sample per type variant). The residual pressure valve shall be connected to a 5 l gas cylinder mounted on a vibration apparatus. The test shall be carried out with an initial pressure of 0,5 bar in the gas c
15、ylinder and with the main valve orifice open. After being subjected to vibration for 2,5 h (equivalent to 4 000 km, see MIL-STD-810F) along the axis of the residual pressure mechanism, the cylinder pressure shall be greater than or equal to 0,25 bar. For carrying out the test in the laboratory, see
16、for example MIL-STD-810F, Method 514.5, Procedure I, reference spectrum of figure 514.5C-1.” Page 15, Bibliography Add the following reference at the end of the list: “7 MIL-STD-810F, Department of Defense Test Method Standard for Environmental Engineering Considerations and Laboratory Tests” ISO 15996:2005/Amd.1:2007(E) ICS 23.020.30 Price based on 1 page ISO 2007 All rights reserved