1、 IEC 62394 Edition 3.0 2017-04 INTERNATIONAL STANDARD Service diagnostic interface for consumer electronics products and networks Implementation for echonet IEC 62394:2017-04(en) colour inside THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2017 IEC, Geneva, Switzerland All rights reserved. Unless
2、 otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in the country of the requester. If you have an
3、y questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. IEC Central Office Tel.: +41 22 919 02 11 3, rue de Varemb Fax: +41 22 919 03 00 CH-1211 Gen
4、eva 20 infoiec.ch Switzerland www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of I
5、EC publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. IEC Catalogue - webstore.iec.ch/catalogue The stand-alone application for consulting the entire bibliographical information on IEC Inte
6、rnational Standards, Technical Specifications, Technical Reports and other documents. Available for PC, Mac OS, Android Tablets and iPad. IEC publications search - www.iec.ch/searchpub The advanced search enables to find IEC publications by a variety of criteria (reference number, text, technical co
7、mmittee,). It also gives information on projects, replaced and withdrawn publications. IEC Just Published - webstore.iec.ch/justpublished Stay up to date on all new IEC publications. Just Published details all new publications released. Available online and also once a month by email. Electropedia -
8、 www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing 20 000 terms and definitions in English and French, with equivalent terms in 16 additional languages. Also known as the International Electrotechnical Vocabulary (IEV) online. IEC Glossary - std.
9、iec.ch/glossary 65 000 electrotechnical terminology entries in English and French extracted from the Terms and Definitions clause of IEC publications issued since 2002. Some entries have been collected from earlier publications of IEC TC 37, 77, 86 and CISPR. IEC Customer Service Centre - webstore.i
10、ec.ch/csc If you wish to give us your feedback on this publication or need further assistance, please contact the Customer Service Centre: csciec.ch. IEC 62394 Edition 3.0 2017-04 INTERNATIONAL STANDARD Service diagnostic interface for consumer electronics products and networks Implementation for ec
11、honet INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 33.160.99; 35.110 ISBN 978-2-8322-4153-0 Registered trademark of the International Electrotechnical Commission Warning! Make sure that you obtained this publication from an authorized distributor. colour inside 2 IEC 62394:2017 IEC 2017 CONTENTS FO
12、REWORD . 23 INTRODUCTION . 25 1 Scope 26 2 Normative references 26 3 Terms, definitions and abbreviated terms 26 3.1 Terms and definitions 26 3.2 Abbreviated terms . 27 4 Different types of service diagnostics 28 4.1 Stand-alone products 28 4.2 Facilities or household appliances network . 28 4.3 Rem
13、ote diagnosis . 28 5 SDI requirements . 28 5.1 General . 28 5.2 Hardware 28 5.2.1 Tester hardware 28 5.2.2 Facilities or household appliances network 28 5.2.3 DUT hardware . 28 5.3 Software . 29 5.3.1 General . 29 5.3.2 Tester software 29 5.3.3 DUT software requirements for the SDI . 29 6 Tester sof
14、tware requirements 29 6.1 Reading the property diagnostic unit . 29 6.2 General information (product identification) . 30 6.3 Diagnosis information . 30 7 Control protocol 1st . 30 7.1 General . 30 7.2 Frame format 30 7.2.1 General . 30 7.2.2 ECHONET headers (EHD) 31 7.2.3 Source/Destination ECHONET
15、 address (SEA/DEA) . 32 7.2.4 ECHONET byte counter (EBC). 34 7.2.5 ECHONET data (EDATA) . 34 7.2.6 Object message header (OHD) 34 7.2.7 ECHONET objects (EOJ) . 35 7.2.8 ECHONET property (EPC) . 36 7.2.9 ECHONET service (ESV) . 37 7.2.10 ECHONET property value data (EDT) 52 7.2.11 Compound ECHONET Se
16、rvice (CpESV) 52 7.2.12 Processing target property counter (OPC) . 58 7.2.13 Property data counter (PDC) 59 8 Control protocol 2nd 59 8.1 General . 59 8.2 Frame format 59 8.2.1 General . 59 8.2.2 ECHONET Lite Header (ELHD) 60 IEC 62394:2017 IEC 2017 3 8.2.3 Transaction ID (TID) 61 8.2.4 ECHONET Lite
17、 Data (ELDATA) . 61 8.2.5 ECHONET Objects (EOJ) 61 8.2.6 ECHONET Lite Service (ELSV) 62 8.2.7 ECHONET property (EPC) . 70 8.2.8 ECHONET Lite Property data counter (ELPDC) . 71 9 ECHONET objects: detailed specifications . 72 9.1 Basic concept . 72 9.2 ECHONET properties: basic specifications 73 9.2.1
18、 General . 73 9.2.2 ECHONET property value data types . 73 9.2.3 Property value range . 73 9.2.4 Required class properties 74 9.2.5 Array . 74 9.3 Device object super class specifications . 75 9.3.1 General . 75 9.3.2 Overview of device object super class specifications . 75 9.3.3 Operation status p
19、roperty 78 9.3.4 Installation location property 78 9.3.5 Standard version information property . 80 9.3.6 Identification number property . 80 9.3.7 Measured instantaneous power consumption property . 81 9.3.8 Measured cumulative power consumption property 81 9.3.9 Manufacturers fault code property .
20、 81 9.3.10 Current limit setting property 81 9.3.11 Fault-status property 82 9.3.12 Fault description property 82 9.3.13 Manufacturer code property . 84 9.3.14 Business facility code property 84 9.3.15 Product code property . 84 9.3.16 Production number property . 85 9.3.17 Production date property
21、. 85 9.3.18 Power-saving operation setting property 85 9.3.19 Remote control setting property . 85 9.3.20 Current time setting property . 85 9.3.21 Current date setting property . 86 9.3.22 Power limit setting property . 86 9.3.23 Cumulative operating time property . 86 9.3.24 Property map property
22、. 86 9.4 Temperature sensor class specifications . 87 9.4.1 General . 87 9.4.2 Operation status property 87 9.4.3 Measured temperature value property 88 9.5 Humidity sensor class specifications . 88 9.5.1 General . 88 9.5.2 Operation status property 88 9.5.3 Measured value of relative humidity prope
23、rty . 88 9.6 Illuminance sensor class specifications . 88 9.6.1 General . 88 4 IEC 62394:2017 IEC 2017 9.6.2 Operation status property 89 9.6.3 Measured illuminance value 1 property 89 9.6.4 Measured illuminance value 2 property 89 9.7 Human detection sensor class specifications 89 9.7.1 General . 8
24、9 9.7.2 Operation status property 90 9.7.3 Detection threshold level property 90 9.7.4 Human detection status property . 90 9.8 Electric energy sensor class specifications . 90 9.8.1 General . 90 9.8.2 Operation status property 91 9.8.3 Integral electric energy property 91 9.8.4 Small-capacity senso
25、r instantaneous electric energy property . 91 9.8.5 Large-capacity sensor instantaneous electric energy property . 92 9.8.6 Integral electric energy measurement log property . 92 9.8.7 Effective voltage value property . 92 9.9 Open/close sensor class specifications . 92 9.9.1 General . 92 9.9.2 Oper
26、ation status property 93 9.9.3 Degree-of-opening detection status 1 property 93 9.9.4 Detection threshold level property 93 9.9.5 Degree-of-opening detection status 2 property 93 9.10 Current value sensor class specifications 93 9.10.1 General . 93 9.10.2 Operation status property 94 9.10.3 Measured
27、 current value 1 property 94 9.10.4 Rated voltage property to be measured . 94 9.10.5 Measured current value 2 property 94 9.11 Air speed sensor class specifications 94 9.11.1 General . 94 9.11.2 Operation status property 95 9.11.3 Measured value of air speed property 95 9.11.4 Air flow direction pr
28、operty 95 9.12 Water flow rate sensor class specifications . 95 9.12.1 General . 95 9.12.2 Operation status property 96 9.12.3 Integral flow rate property 96 9.12.4 Flow rate property . 96 9.13 Home air conditioner class specifications 96 9.13.1 General . 96 9.13.2 Operation status property 104 9.13
29、.3 Power-saving operation setting 104 9.13.4 Operation mode setting property 104 9.13.5 Automatic temperature control setting property 104 9.13.6 Normal/high-speed/silent operation setting property 104 9.13.7 Set temperature value property 104 9.13.8 Set value of relative humidity in dehumidifying m
30、ode property . 105 9.13.9 Set temperature value in cooling mode property 105 9.13.10 Set temperature value in heating mode property 105 IEC 62394:2017 IEC 2017 5 9.13.11 Set temperature value in dehumidifying mode property 105 9.13.12 Rated power consumption property 106 9.13.13 Measured value of cu
31、rrent consumption property . 106 9.13.14 Measured value of room relative humidity property 106 9.13.15 Measured value of room temperature property . 106 9.13.16 Set temperature value of user remote control property . 107 9.13.17 Measured cooled air temperature property . 107 9.13.18 Measured outdoor
32、 air temperature property . 107 9.13.19 Relative temperature setting property 107 9.13.20 Air flow rate setting property 107 9.13.21 Automatic control of air flow direction setting property . 108 9.13.22 Automatic swing of air flow setting property . 108 9.13.23 Air flow direction (vertical) setting
33、 property 108 9.13.24 Air flow direction (horizontal) setting property 109 9.13.25 Special state property 110 9.13.26 Non-priority state property . 110 9.13.27 Ventilation function setting property . 110 9.13.28 Humidifier function setting property . 110 9.13.29 Ventilation air flow rate setting . 1
34、11 9.13.30 Degree of humidification setting . 111 9.13.31 Mounted air cleaning method property . 111 9.13.32 Air purifier function setting property . 111 9.13.33 Air refresh method . 112 9.13.34 Air refresher function setting property 113 9.13.35 Self-cleaning method property . 113 9.13.36 Self-clea
35、ning function setting property . 114 9.13.37 Special function setting property 115 9.13.38 Operation status of components property . 115 9.13.39 Thermostat setting override function property 115 9.13.40 Air purification mode setting property . 116 9.13.41 ON timer-based reservation setting property
36、116 9.13.42 ON timer setting (time) property . 116 9.13.43 ON timer setting (relative time) 116 9.13.44 OFF timer-based reservation setting property 117 9.13.45 OFF timer setting (time) property . 117 9.13.46 OFF timer setting (relative time) property. 117 9.14 Ventilation fan class specifications 1
37、17 9.14.1 General . 117 9.14.2 Operation status property 118 9.14.3 Ventilation auto setting property 118 9.14.4 Set value of ventilation air flow rate property . 118 9.15 Air purifier class specifications 118 9.15.1 General . 118 9.15.2 Operation status property 119 9.15.3 Filter change notice prop
38、erty . 119 9.15.4 Air flow rate setting property 119 9.15.5 Smoke (cigarette) detection status property . 120 9.15.6 Optical catalyst operation setting property . 120 9.15.7 Air pollution detection status property 120 6 IEC 62394:2017 IEC 2017 9.16 Humidifier class specifications 120 9.16.1 General
39、. 120 9.16.2 Operation status property 122 9.16.3 Humidifying setting 1 property . 122 9.16.4 Humidifying setting 2 property . 122 9.16.5 Measured value of relative humidity property . 122 9.16.6 Reservation setting of OFF timer property . 122 9.16.7 Relative time value setting of OFF timer property
40、 122 9.16.8 Ion emission setting property . 122 9.16.9 Implemented ion emission method property . 123 9.16.10 Water amount level property 123 9.17 Requirements for package-type commercial air conditioner (indoor unit) class specifications 123 9.17.1 General . 123 9.17.2 Operation status property 129
41、 9.17.3 Operation mode setting property 129 9.17.4 Temperature setting 1 property 129 9.17.5 Relative humidity setting for dehumidification mode 1 property 129 9.17.6 Temperature setting for cooling mode 1 property . 130 9.17.7 Temperature setting for heating mode 1 property . 130 9.17.8 Temperature
42、 setting for dehumidification mode 1 property . 130 9.17.9 Rated power consumption of indoor unit property 130 9.17.10 Measured electric current consumption of the indoor unit property . 131 9.17.11 Measured indoor relative humidity 1 property . 131 9.17.12 Measured indoor temperature 1 property . 1
43、31 9.17.13 Relative temperature setting property 131 9.17.14 Air flow rate setting property 131 9.17.15 “Air flow direction (vertical)” setting property 132 9.17.16 “Air flow direction (horizontal)” setting property 132 9.17.17 “Special” state property . 132 9.17.18 Thermostat state property 133 9.1
44、7.19 Current function (“automatic” operation mode) property . 133 9.17.20 Ventilation mode setting property . 133 9.17.21 Combined operation of indoor unit and total heat exchanger property 134 9.17.22 Ventilation air flow rate setting property . 134 9.17.23 “Disabling of air conditioner” setting pr
45、operty . 134 9.17.24 Group information property 134 9.17.25 Thermostat setting override function property 135 9.17.26 Filter cleaning reminder lamp setting property . 135 9.17.27 Measured power consumption of indoor unit property 135 9.17.28 Aperture of expansion valve property . 135 9.17.29 Tempera
46、ture setting 2 property 135 9.17.30 “Relative humidity setting for dehumidification mode” 2 property 136 9.17.31 “Temperature setting for cooling mode” 2 property . 136 9.17.32 “Temperature setting for heating mode” 2 property . 136 9.17.33 “Temperature setting for dehumidification mode” 2 property
47、. 136 9.17.34 Measured indoor relative humidity 2 property . 136 9.17.35 Measured indoor temperature 2 property . 137 9.17.36 “ON timer-based reservation” setting property . 137 IEC 62394:2017 IEC 2017 7 9.17.37 ON timer setting (time) property . 137 9.17.38 ON timer setting (relative time) property
48、 137 9.17.39 “OFF timer-based reservation” setting property 137 9.17.40 OFF timer setting (time) property . 138 9.17.41 OFF timer setting (relative time) property. 138 9.18 Requirements for package-type commercial air conditioner (outdoor unit) class specifications . 138 9.18.1 General . 138 9.18.2
49、Operation status property 140 9.18.3 Operation mode setting property 140 9.18.4 Rated power consumption of outdoor unit property 140 9.18.5 Measured electric current consumption of outdoor unit property 141 9.18.6 Measured outdoor air temperature 1 property 141 9.18.7 “Special” state property . 141 9.18.8 Group information property 141 9.18.9 Operation status of compressor property . 141 9.18.10 Operation mode information property . 142 9.18.11 Fan rotation speed property . 142 9.18.12 Measured power consumption of outdoor unit pr