欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    IEC 61266-1994 Ultrasonics - Hand-held probe Doppler foetal heartbeat detectors - Performance requirements and methods of measurement and reporting《超声学 手持探头式多普勒胎儿心音检测仪 性能要求及测量和报告方法》.pdf

    • 资源ID:1236254       资源大小:3.99MB        全文页数:64页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    IEC 61266-1994 Ultrasonics - Hand-held probe Doppler foetal heartbeat detectors - Performance requirements and methods of measurement and reporting《超声学 手持探头式多普勒胎儿心音检测仪 性能要求及测量和报告方法》.pdf

    1、NORME CE1 I NTE RN ATION ALE INTERNATIONAL STANDARD I EC 1266 Premire dition First edition 1994-1 2 Ultrasons - Dtecteurs des battements de coeur foetal effet Doppler avec sonde main - Prescriptions de performance et mthodes de mesure et de signalement Ultrasonics - Hand-held probe Doppler foetal he

    2、artbeat detectors - Performance requirements and methods of measurement and reporting Numro de rfrence Reference number CEIA EC 1266: 1994 Numros des publications Depuis le ler janvier 1997, les publications de la CE1 sont numrotes partir de 60000. Publications consolides Les versions consolides de

    3、certaines publications de la CE1 incorporant les amendements sont disponibles. Par exemple, les numros ddition 1.0, 1.1 et 1.2 indiquent respectivement la publication de base, la publication de base incorporant lamendement 1, et la publication de base incorporant les amendements 1 et 2. Validit de l

    4、a prsente publication Le contenu technique des publications de la CE1 est constamment revu par la CE1 afin quil reflte ltat actuel de la technique. Des renseignements relatifs la date de reconfirmation de la publication sont disponibles dans le Catalogue de la CEI. Les renseignements relatifs des qu

    5、estions ltude et des travaux en cours entrepris par le comit technique qui a tabli cette publication, ainsi que la liste des publications tablies, se trouvent dans les documents ci- dessous: Site web de la CEI* Catalogue des publications de la CE1 Publi annuellement et mis jour rgulirement (Catalogu

    6、e en ligne) Disponible la fois au site web, de la CEI* et comme priodique imprim Bulletin de la CE1 Terminologie, symboles graphiques et littraux En ce qui concerne la terminologie gnrale, le lecteur se reportera la CE1 60050: Vocabulaire Electro- technique International (VE i). Pour les symboles gr

    7、aphiques, les symboles littraux et les signes dusage gnral approuvs par la CEI, le lecteur consultera la CE1 60027: Symboles littraux d utiliser en lectrotechnique, la CE1 6041 7: Symboles graphiques utilisables sur le matriel. Index, relev et compilation des feuilles individuelles, et la CE1 6061 7

    8、: Symboles graphiques pour schmas. Voir adresse site web, sur la page de titre. Numbering As from 1 January 1997 all IEC publications are issued with a designation in the 60000 series. Consolidated publications Consolidated versions of some IEC publications including amendments are available. For ex

    9、ample, edition numbers 1 .O, 1 .l and 1.2 refer, respectively, to the base publication, the base publication incorporating amendment 1 and the base publication incorporating amendments 1 and 2. Validity of this publication The technical content of IEC publications is kept under constant review by th

    10、e IEC, thus ensuring that the content reflects current technology. Information relating to the date of the reconfirmation of the publication is available in the IEC catalogue. Information on the subjects under consideration and work in progress undertaken by the technical committee which has prepare

    11、d this publication, as well as the list of publications issued, is to be found at the following IEC sources: IEC web site* Catalogue of IEC publications Published yearly with regular updates (On-line catalogue)* Available both at the IEC web site* and as a printed periodical IEC Bulletin Terminology

    12、, graphical and letter symbols For general terminology, readers are referred to I EC 60050: International Electrotechnical Vocabulary (IEV). For graphical symbols, and letter symbols and signs approved by the IEC for general use, readers are referred to publications IEC 60027: Letter symbols to be u

    13、sed in electrical technology, IEC 60417: Graphical symbols for use on equipment. Index, survey and compilation of the single sheets and IEC 60617: Graphical symbols for diagrams. * See web site address on title page. NORME INTERNATIONALE INTERNATIONAL STANDARD CE1 IEC 1266 Premire dition First editi

    14、on 1994-1 2 Ultrasons - Dtecteurs des battements de coeur foetal effet Doppler avec sonde main - Prescriptions de performance et mthodes de mesure et de signalement Ultrasonics - Hand-held probe Doppler foetal heartbeat detectors - Performance requirements and methods of measurement and reporting 0

    15、CE1 1994 Droits de reproduction rservs - Copyright - all rights reserved Aucune partie de tte publication ne peut tre reproduite ni utilis8e sous quelque forme que soit e( par aucun pro- cd. lectronique ou mcanique. y compris la photocopie et les microfilms, sans Iamrd any IEC National Committee int

    16、erested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization for Standardization (ISO) in accorda

    17、nce with conditions determined by agreement between the two organizations. The formal decisions or agreements of the IEC on technical matters, prepared by technical committees on which all the National Committees having a special interest therein are represented, express, as nearly as possible, an i

    18、nternational consensus of opinion on the subjects dealt with. They have the form of recommendations for international use published in the form of standards, technical reports or guides and they are accepted by the National Committees in that sense. In order to promote international unification, IEC

    19、 National Committees undertake to apply IEC International Standards transparently to the maximum extent possible in their national and regional standards. Any divergence between the IEC Standard and the corresponding national or regional standard shall be clearly indicated in the latter. internation

    20、al Standard iEC 1266 has been prepared by IEC technical committee 87: Ultrasonics. The text of this standard is based on the following documents: Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. Ail annexes are for in

    21、formation only In this standard the following print types are used: - - Requirements proper: in roman type. Test specifications: in italic type. Words in bold in the text are defined in clause 3. - Notes: in smaller roman type. - -6- 1266 O CEI:l994 INTRODUCTION Les dtecteurs des battements de coeur

    22、 foetal ultrasonores a effet Doppler avec sonde main sont largement utiliss pour surveiller le coeur foetal pendant la grossesse. Ils fonctionnent normalement des frquences denviron 2 MHz et comportent un trans- ducteur ultrasons coupl dans le domaine acoustique labdomen maternel et de lappareillage

    23、 lectronique. Un faisceau dultrasons est dirig par loprateur de manire atteindre le coeur foetal et une faible partie des ultrasons incidents est rflchie par la surface mobile du coeur. Ces ultrasons sont soumis une drive en frquence par effet Doppler. On les dtecte alors grce un transducteur rcepte

    24、ur. Le traitement des signaux spare les signaux basse frquence associs aux battements du coeur foetal et les oscillations ultrasoniques haute frquence, et les amplifie pour une dtection audio. La prsente Norme internationale, la CE1 1266, spcifie des mthodes dvaluation des performances des dtecteurs

    25、 des battements de coeur foetal ultrasonores et, en particulier, elle spcifie une mthode de dtermination de la sensibilit du systme pour la dtection dune cible mobile. Les systmes de surveillance foetale Doppler utilisent une sonde plate attache au patient et fonctionnent suivant le mme principe que

    26、 les dtecteurs des battements de coeur foetal avec sonde main mais ne sont pas couverts par cette norme. La raison en est que les systmes de surveillance ncessitent un angle large dexamen ralis souvent par lutilisation dun transducteur plusieurs elements. Celle-ci rend la mise en oeuvre des appareil

    27、s de surveillance foetale a Doppler beaucoup plus complexe que celle des dtecteurs des battements de coeur foetal avec sonde a main qui utilise un faisceau troit. Les mthodes de vrification des performances seraient aussi plus complexes. 1266 0 IEC:1994 -7- INTRODUCTION I md-held ultrasonic Doppler

    28、foetal heartbeat detectors are widely u L 3d for m nitoring foetal heartbeat during pregnancy. They normally operate at frequencies of circa 2 MHz, and consist of an ultrasonic transducer acoustically coupled to the maternal abdomen and associated electronics. A beam of ultrasound is directed by the

    29、 operator to impinge on the foetal heart and a small fraction of the incident ultrasound is reflected from the moving surfaces of the heart. This ultrasound is subject to a frequency shift as a result of the Doppler effect. It is then detected by a receiving transducer. Signal processing separates t

    30、he low-frequency signals associated with the foetal heartbeat from the high-frequency ultrasonic oscillations and amplifies them for audio detection. This International Standard, IEC 1266, specifies methods of evaluating the performance of ultrasonic foetal heartbeat detectors and, in particular, sp

    31、ecifies a method of determining the sensitivity of the system to the detection of a moving target. Foetal Doppler monitoring devices use a flat probe strapped to the patient and work on a principle similar to that of hand-held foetal heartbeat detectors but are not covered by this standard. The reas

    32、on is that monitoring devices require a wide angle of view which is often realised by using a multi-element transducer. This makes the method of operation of foetal Doppler monitors much more complex than that of hand-held foetal heartbeat detec- tors which use a narrow beam. Methods of assessment of performance would also be more complex.


    注意事项

    本文(IEC 61266-1994 Ultrasonics - Hand-held probe Doppler foetal heartbeat detectors - Performance requirements and methods of measurement and reporting《超声学 手持探头式多普勒胎儿心音检测仪 性能要求及测量和报告方法》.pdf)为本站会员(Iclinic170)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开