1、 IEC 61195 Edition 2.1 2012-10 INTERNATIONAL STANDARD NORME INTERNATIONALE Double-capped fluorescent lamps Safety specifications Lampes fluorescence deux culots Prescriptions de scurit IEC61195:1999+A1:2012 colourinsideTHIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2012 IEC, Geneva, Switzerland A
2、ll rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in the country of the
3、 requester. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. Droits de reproduction rservs. Sauf indication contraire, aucune p
4、artie de cette publication ne peut tre reproduite ni utilise sous quelque forme que ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie et les microfilms, sans laccord crit de la CEI ou du Comit national de la CEI du pays du demandeur. Si vous avez des questions sur le copyr
5、ight de la CEI ou si vous dsirez obtenir des droits supplmentaires sur cette publication, utilisez les coordonnes ci-aprs ou contactez le Comit national de la CEI de votre pays de rsidence. IEC Central Office Tel.: +41 22 919 02 11 3, rue de Varemb Fax: +41 22 919 03 00 CH-1211 Geneva 20 infoiec.ch
6、Switzerland www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publications is
7、 kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Useful links: IEC publications search - www.iec.ch/searchpub The advanced search enables you to find IEC publications by a variety of criteria (reference
8、 number, text, technical committee,). It also gives information on projects, replaced and withdrawn publications. IEC Just Published - webstore.iec.ch/justpublished Stay up to date on all new IEC publications. Just Published details all new publications released. Available on-line and also once a mo
9、nth by email. Electropedia - www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 30 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical Vocabular
10、y (IEV) on-line. Customer Service Centre - webstore.iec.ch/csc If you wish to give us your feedback on this publication or need further assistance, please contact the Customer Service Centre: csciec.ch. A propos de la CEI La Commission Electrotechnique Internationale (CEI) est la premire organisatio
11、n mondiale qui labore et publie des Normes internationales pour tout ce qui a trait llectricit, llectronique et aux technologies apparentes. A propos des publications CEI Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possdez ldition la plus rcen
12、te, un corrigendum ou amendement peut avoir t publi. Liens utiles: Recherche de publications CEI - www.iec.ch/searchpub La recherche avance vous permet de trouver des publications CEI en utilisant diffrents critres (numro de rfrence, texte, comit dtudes,). Elle donne aussi des informations sur les p
13、rojets et les publications remplaces ou retires. Just Published CEI - webstore.iec.ch/justpublished Restez inform sur les nouvelles publications de la CEI. Just Published dtaille les nouvelles publications parues. Disponible en ligne et aussi une fois par mois par email. Electropedia - www.electrope
14、dia.org Le premier dictionnaire en ligne au monde de termes lectroniques et lectriques. Il contient plus de 30 000 termes et dfinitions en anglais et en franais, ainsi que les termes quivalents dans les langues additionnelles. Egalement appel Vocabulaire Electrotechnique International (VEI) en ligne
15、. Service Clients - webstore.iec.ch/csc Si vous dsirez nous donner des commentaires sur cette publication ou si vous avez des questions contactez-nous: csciec.ch. IEC 61195 Edition 2.1 2012-10 INTERNATIONAL STANDARD NORME INTERNATIONALE Double-capped fluorescent lamps Safety specifications Lampes fl
16、uorescence deux culots Prescriptions de scurit INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE CJ ICS 29.140.30 PRICE CODE CODE PRIX ISBN 978-2-8322-0415-3 Registered trademark of the International Electrotechnical Commission Marque dpose de la Commission Electro
17、technique Internationale Warning! Make sure that you obtained this publication from an authorized distributor. Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agr. colourinside 2 61195 IEC:1999+A1:2012 CONTENTS FOREWORD . 4 INTRODUCTION . 6 1 General 7 1.1
18、 Scope 7 1.2 Normative references 7 1.3 Definitions . 8 2 Safety requirements 9 2.1 General . 9 2.2 Marking . 9 2.3 Mechanical requirements for caps 9 2.4 Insulation resistance 11 2.5 Electric strength 11 2.6 Parts which can become accidentally live . 11 2.7 Resistance to heat and fire 11 2.8 Creepa
19、ge distance for caps . 12 2.9 Lamp cap temperature rise 12 2.10 Lamp minimum overall length 13 2.11 Information for luminaire design . 13 2.12 Information for ballast design . 13 2.13 UV radiation 13 3 Assessment 14 3.1 General . 14 3.2 Whole production assessment by means of the manufacturers recor
20、ds . 14 3.3 Assessment of the manufacturers records of particular tests . 18 3.4 Rejection conditions of batches 18 3.5 Sampling procedures for whole production testing 19 3.6 Sampling procedures for batch testing . 19 Annex A (normative) Test holder for torsion test for G5 and G13 capped lamps . 21
21、 Annex B (normative) Test for lamp cap temperature rise . 22 Annex C (informative) Information for luminaire design 23 Annex D (normative) Conditions of compliance for design tests . 24 Annex E (informative) Information for ballast design 25 Bibliography 26 Figure 1 Temperature measuring point . 13
22、Figure A.1 Holder for torsion tests on lamps with bi-pin caps 21 Table 1 Torque values for unused lamps 10 Table 2 Torque values after heating treatment 10 Table 3 Sheet references of IEC 60061 11 Table 4 Grouping of test records Sampling and acceptable quality levels . 15 61195 IEC:1999+A1:2012 3 T
23、able 5 Acceptance numbers AQL = 0,65 % . 16 Table 6 Acceptance numbers AQL = 2,5 % . 17 Table 7 Batch sample size and rejection number 19 4 61195 IEC:1999+A1:2012 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ DOUBLE-CAPPED FLUORESCENT LAMPS SAFETY SPECIFICATIONS FOREWORD 1) The International Electrote
24、chnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To t
25、his end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC Nationa
26、l Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO)
27、 in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation fro
28、m all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be he
29、ld responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any d
30、ivergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to I
31、EC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual
32、experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this I
33、EC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this I
34、EC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. This consolidated version of IEC 61195 consists of the second edition (1999) documents 34A/886/FDIS and 34A/900/RVD, its amendment 1 (2012) documents 34A/1536/CDV and
35、34A/1577/RVC and its corrigendum of August 2000. It bears the edition number 2.1. The technical content is therefore identical to the base edition and its amendment and has been prepared for user convenience. A vertical line in the margin shows where the base publication has been modified by amendme
36、nt 1. Additions and deletions are displayed in red, with deletions being struck through. 61195 IEC:1999+A1:2012 5 International Standard IEC 61195 has been prepared by sub-committee 34A: Lamps, of IEC technical committee 34: Lamps and related equipment. Annexes A, B and D form an integral part of th
37、is standard. Annexes C and E are for information only. The committee has decided that the contents of the base publication and its amendments will remain unchanged until the stability date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At
38、 this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. IMPORTANT The “colour inside” logo on the cover page of this publication indicates that it contains colours which are considered to be useful for the correct understanding of its contents. Users sh
39、ould therefore print this publication using a colour printer. 6 61195 IEC:1999+A1:2012 INTRODUCTION The standards IEC 62471 and IEC/TR 62471-2 contain horizontal requirements available that need to be introduced into product standards, e.g. to IEC 61195. The horizontal requirements are transformed i
40、nto requirements for double-capped fluorescent lamps. The lamps within the scope of this standard are general lighting service (GLS) lamps according to the definition 3.11 of IEC 62471:2006,“.lamps intended for lighting spaces that are typically occupied or viewed by people.“ According to Clause 6 o
41、f IEC 62471:2006, radiation of GLS lamps is measured at a distance equivalent to 500 lx. Measured at the 500 lx distance, GLS lamps will not exceed risk group 1 for blue light hazard and risk group 0 for IR radiation. This combination of risk group and hazard does not require marking (Table 1 of IEC
42、/TR 62471-2:2009). Hazards from UV radiation of GLS lamps are now covered in 2.13 of IEC 61195. Hence, IEC 62471 does not require any additional marking for GLS lamps. 61195 IEC:1999+A1:2012 7 DOUBLE-CAPPED FLUORESCENT LAMPS SAFETY SPECIFICATIONS 1 General 1.1 Scope This International Standard speci
43、fies the safety requirements for double-capped fluorescent lamps for general lighting purposes of all groups having Fa6, Fa8, G5, G13, 2G13, R17d and W4.38.5d caps. It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole
44、production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure which can be used to make limited assessment of batches are also given in this standard. This part of the standard covers phot
45、obiological safety according to IEC 62471 and IEC/TR 62471-2. Blue light and infrared hazards are below the level which requires marking. NOTE Compliance with this standard concerns only safety criteria and does not take into account the performance of double-capped fluorescent lamps for general lig
46、hting purposes with respect to luminous flux, colour, starting and operational characteristics. Readers are referred to IEC 60081 for such characteristics. 1.2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only t
47、he edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60061-1, Lamp caps and holders together with gauges for the control of interchangeability and safety Part 1: Lamp caps IEC 60061-2, Lamp caps and holders together w
48、ith gauges for the control of interchangeability and safety Part 2: Lampholders IEC 60061-3, Lamp caps and holders together with gauges for the control of interchangeability and safety Part 3: Gauges IEC 60081, Double-capped fluorescent lamps Performance specifications IEC 60410, Sampling plans and
49、procedures for inspection by attributes IEC 60695-2-1/0, Fire hazard testing Part 2: Test methods Section 1/sheet 0: Glow-wire test methods General IEC 60921, Ballasts for tubular fluorescent lamps Performance requirements 8 61195 IEC:1999+A1:2012 1.3 Definitions For the purposes of this International Standard, the following definitions apply. 1.3.1 double-capped fluorescent lamp double-cappe