欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    IEC 61156-8-2009 Multicore and symmetrical pair quad cables for digital communications - Part 8 Symmetrical pair quad cables with transmission characteristics up to 1200 MHz - Work.pdf

    • 资源ID:1235909       资源大小:900.60KB        全文页数:22页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    IEC 61156-8-2009 Multicore and symmetrical pair quad cables for digital communications - Part 8 Symmetrical pair quad cables with transmission characteristics up to 1200 MHz - Work.pdf

    1、 IEC 61156-8Edition 1.0 2009-05INTERNATIONAL STANDARD Multicore and symmetrical pair/quad cables for digital communications Part 8: Symmetrical pair/quad cables with transmission characteristics up to 1 200 MHz Work area wiring Sectional specification IEC61156-8:2009(E) THIS PUBLICATION IS COPYRIGHT

    2、 PROTECTED Copyright 2009 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or

    3、IECs member National Committee in the country of the requester. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. IEC Central Of

    4、fice 3, rue de Varemb CH-1211 Geneva 20 Switzerland Email: inmailiec.ch Web: www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. Ab

    5、out IEC publications The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Catalogue of IEC publications: www.iec.ch/searchpub The IEC on-line Catalogue enables yo

    6、u to search by a variety of criteria (reference number, text, technical committee,). It also gives information on projects, withdrawn and replaced publications. IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Published details twice a month all ne

    7、w publications released. Available on-line and also by email. Electropedia: www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known

    8、as the International Electrotechnical Vocabulary online. Customer Service Centre: www.iec.ch/webstore/custserv If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: csciec.ch Tel.: +41 22 919 02 11 Fax:

    9、 +41 22 919 03 00 IEC 61156-8Edition 1.0 2009-05INTERNATIONAL STANDARD Multicore and symmetrical pair/quad cables for digital communications Part 8: Symmetrical pair/quad cables with transmission characteristics up to 1 200 MHz Work area wiring Sectional specification INTERNATIONAL ELECTROTECHNICAL

    10、COMMISSION QICS 33.120.20 PRICE CODEISBN 2-8318-1040-9 Registered trademark of the International Electrotechnical Commission 2 61156-8 IEC:2009(E) CONTENTS FOREWORD.4 1 Scope.6 2 Normative references6 3 Terms and definitions .6 4 Installation considerations.7 4.1 Installation conditions 7 4.2 Climat

    11、ic conditions.7 5 Materials and cable construction .7 5.1 General remarks7 5.2 Cable construction.7 5.2.1 Conductor7 5.2.2 Insulation.7 5.2.3 Cable element .7 5.2.4 Cable make-up 8 5.2.5 Screening of cable core .8 5.2.6 Sheath.8 5.2.7 Identification 8 5.2.8 Finished cable .8 6 Characteristics and re

    12、quirements8 6.1 General remarks8 6.2 Electrical characteristics 9 6.2.1 Conductor resistance .9 6.2.2 Resistance unbalance9 6.2.3 Dielectric strength9 6.2.4 Insulation resistance 9 6.2.5 Mutual capacitance 9 6.2.6 Capacitance unbalance9 6.2.7 Transfer impedance.9 6.2.8 Coupling attenuation 10 6.2.9

    13、Current-carrying capacity .10 6.2.10 Shield resistance .10 6.3 Transmission characteristics10 6.3.1 Velocity of propagation (phase velocity) .10 6.3.2 Phase delay and differential delay (delay skew)10 6.3.3 Attenuation 11 6.3.4 Unbalance attenuation .11 6.3.5 Near-end crosstalk (NEXT).11 6.3.6 Far-e

    14、nd crosstalk (FEXT) .12 6.3.7 Alien (exogenous) near-end crosstalk 12 6.3.8 Alien (exogenous) far-end crosstalk .12 6.3.9 Alien (exogenous) crosstalk of bundled cables .12 6.3.10 Impedance.12 6.3.11 Return loss (RL).12 6.4 Mechanical and dimensional characteristics and requirements .13 6.4.1 Dimensi

    15、onal requirements13 6.4.2 Elongation at break of the conductors 13 61156-8 IEC:2009(E) 3 6.4.3 Tensile strength of the insulation13 6.4.4 Elongation at break of the insulation.13 6.4.5 Adhesion of the insulation to the conductor 13 6.4.6 Elongation at break of the sheath.13 6.4.7 Tensile strength of

    16、 the sheath 13 6.4.8 Crush test of the cable.13 6.4.9 Impact test of the cable13 6.4.10 Bending under tension .13 6.4.11 Repeated bending of the cable.13 6.4.12 Tensile performance of the cable .13 6.4.13 Shock test of the cable.14 6.4.14 Bump test of the cable .14 6.4.15 Vibration test of a cable .

    17、14 6.5 Environmental characteristics 14 6.5.1 Shrinkage of insulation.14 6.5.2 Wrapping test of insulation after thermal ageing.14 6.5.3 Bending test of insulation at low temperature .14 6.5.4 Elongation at break of the sheath after ageing14 6.5.5 Tensile strength of the sheath after ageing.14 6.5.6

    18、 Sheath pressure test at high temperature.14 6.5.7 Cold bend test of the cable 14 6.5.8 Heat shock test14 6.5.9 Damp heat steady state .14 6.5.10 Solar radiation .15 6.5.11 Solvents and contaminating fluids 15 6.5.12 Salt mist and sulphur dioxide .15 6.5.13 Water immersion .15 6.5.14 Hygroscopicity

    19、.15 6.5.15 Wicking .15 6.5.16 Flame propagation characteristics of a single cable15 6.5.17 Flame propagation characteristics of bunched cables.15 6.5.18 Halogen gas evolution15 6.5.19 Smoke generation15 6.5.20 Toxic gas emission 15 6.5.21 Integrated fire test .15 7 Introduction to the blank detail s

    20、pecification 16 Bibliography17 Table 1 Transfer impedance.10 Table 2 Coupling attenuation 10 Table 3 Attenuation, constant values 11 Table 4 Return loss (RL).12 4 61156-8 IEC:2009(E) INTERNATIONAL ELECTROTECHNICAL COMMISSION _ MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS Par

    21、t 8: Symmetrical pair/quad cables with transmission characteristics up to 1 200 MHz Work area wiring Sectional specification FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC Nation

    22、al Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicl

    23、y Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmen

    24、tal organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on te

    25、chnical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by

    26、 IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uni

    27、formity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5

    28、) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directo

    29、rs, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising o

    30、ut of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn

    31、 to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 61156-8 has been prepared by subcommittee 46C: Wires and symmetric cables, of IEC tec

    32、hnical committee 46: Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories. The text of this standard is based on the following documents: FDIS Report on voting 46C/887/FDIS 46C/894/RVD Full information on the voting for the approval of this standard can b

    33、e found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. 61156-8 IEC:2009(E) 5 A list of all parts of the IEC 61156 series, under the general title: Multicore and symmetrical pair/quad cables for digital commun

    34、ications, can be found on the IEC website. The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publicatio

    35、n will be reconfirmed, withdrawn, replaced by a revised edition, or amended. A bilingual version of this publication may be issued at a later date. 6 61156-8 IEC:2009(E) MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS Part 8: Symmetrical pair/quad cables with transmission chara

    36、cteristics up to 1 200 MHz Work area wiring Sectional specification 1 Scope This sectional specification relates to IEC 61156-1 and IEC 61156-7. The cables described herein are specified up to 1 200 MHz and are specifically designed to build patch, equipment, and work area cables as defined in ISO/I

    37、EC 11801 and ISO/IEC 15018. It covers a cable having four individually screened (STP) pairs. The cable may be provided with a common screen over the cable core. The transmission characteristics are specified for a frequency range 4 MHz to 1 200 MHz and at 20 C. These cables can be used for various c

    38、ommunication channels which use as many as four pairs simultaneously. In this sense, this sectional specification provides the cable characteristics required by system developers to evaluate new systems. The cables covered by this sectional specification are intended to operate with voltages and cur

    39、rents normally encountered in communication systems. These cables are not intended to be used in conjunction with low impedance sources, for example the electric power supplies of public utility mains. 2 Normative references The following referenced documents are indispensable for the application of

    40、 this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60304, Standard colours for insulation for low-frequency cables and wires IEC 61156-1:2007, Multicore and symmetrical pa

    41、ir/quad cables for digital communications Part 1: Generic specification IEC 61156-7, Multicore and symmetrical pair/quad cables for digital communications Part 7: Symmetrical pair cables with transmission characteristics up to 1 200 MHz Sectional specification for digital and analog communication ca

    42、bles 3 Terms and definitions For the purposes of this document, the terms and definitions defined in IEC 61156-1 apply. 61156-8 IEC:2009(E) 7 4 Installation considerations 4.1 Installation conditions Installation considerations are defined in Clause 4 of IEC 61156-1. 4.2 Climatic conditions Under st

    43、atic conditions, the cables shall operate in the temperature range from 20 C to +60 C. The temperature dependence of the cables is specified, and should be taken into account for the design of an actual cabling system. 5 Materials and cable construction 5.1 General remarks The choice of materials an

    44、d cable construction shall be suitable for the intended application and installation of the cable. Particular care shall be taken to meet any special requirements for the fire performance (such as burning properties, smoke generation, evolution of halogen gas, etc.). 5.2 Cable construction The cable

    45、 construction shall be in accordance with the details and dimensions given in the relevant detail specification. 5.2.1 Conductor The conductor shall be solid or stranded annealed copper conductor, in accordance with IEC 61156-1 and shall have a nominal diameter between 0,4 mm to 0,65 mm. The strande

    46、d conductor should have preferably seven strands. Higher conductor diameters may be used if compatible with the connecting hardware. 5.2.2 Insulation The conductor shall be insulated with a suitable thermoplastic material. Examples of suitable materials are polyolefin; fluoropolymer; low-smoke zero-

    47、halogen thermoplastic material. The insulation may be solid or cellular with or without a solid dielectric skin. The insulation shall be continuous and shall have a thickness such that the completed cable meets the specified requirements. The insulation colour code is not specified but shall be indi

    48、cated in the relevant detail specification. The colours shall be readily identifiable and shall correspond reasonably with the standard colours shown in IEC 60304. NOTE It is acceptable to mark or stripe the “a“ wire with the colour of the “b“ wire to facilitate pair identification. 5.2.3 Cable elem

    49、ent The cable element shall be screened pair or quad adequately twisted. The screen of the cable element shall be in accordance with 5.2.3.1 of IEC 61156-1. 8 61156-8 IEC:2009(E) 5.2.4 Cable make-up A spacer may be used to separate the cable elements. The cable elements, including spacers, shall be assembled to form the cable core. The core of the cable may be wrapped with a protective layer of non-hygroscopic and not-wicking material. 5.2.5 Screening of cable


    注意事项

    本文(IEC 61156-8-2009 Multicore and symmetrical pair quad cables for digital communications - Part 8 Symmetrical pair quad cables with transmission characteristics up to 1200 MHz - Work.pdf)为本站会员(feelhesitate105)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开