欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    BS EN 50121-5-2006 铁路设施.电磁兼容性.固定供电设备的辐射和抗干扰.pdf

    • 资源ID:115263       资源大小:265.61KB        全文页数:22页
    • 资源格式: PDF        下载积分:5000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要5000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    BS EN 50121-5-2006 铁路设施.电磁兼容性.固定供电设备的辐射和抗干扰.pdf

    1、BRITISH STANDARDBS EN 50121-5:2006Railway applications Electromagnetic compatibility Part 5: Emission and immunity of fixed power supply installations and apparatusThe European Standard EN 50121-5:2006 has the status of a British StandardICS 29.020; 29.280; 45.020g49g50g3g38g50g51g60g44g49g42g3g58g4

    2、4g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 50121-5:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 29 September

    3、 2006 BSI 2006ISBN 0 580 49111 0National forewordThis British Standard was published by BSI. It is the UK implementation of EN 50121-5:2006. It supersedes BS EN 50121-5:2000 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee GEL/9, Railway electrotechnica

    4、l applications.A list of organizations represented on GEL/9 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity

    5、 from legal obligations.Amendments issued since publicationAmd. No. Date Comments EUROPEAN STANDARD EN 50121-5 NORME EUROPENNE EUROPISCHE NORM July 2006 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechn

    6、ische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50121-5:2006 E ICS 29.020; 29.280; 45.020 Supersedes EN 50121-5:2000English version Railway applications

    7、 - Electromagnetic compatibility Part 5: Emission and immunity of fixed power supply installations and apparatus Applications ferroviaires - Compatibilit lectromagntique Partie 5: Emission et immunit des installations fixes dalimentation de puissance et des quipements associs Bahnanwendungen - Elekt

    8、romagnetische Vertrglichkeit Teil 5: Straussendungen und Strfestigkeit von ortsfesten Anlagen und Einrichtungen der BahnenergieversorgungThis European Standard was approved by CENELEC on 2006-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the con

    9、ditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in

    10、three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotech

    11、nical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the Uni

    12、ted Kingdom. Foreword This European Standard was prepared by Technical Committee TC 9X: Electrical and electronic applications for railways. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50121-5 on 2006-07-01. This European Standard supersedes EN 50121-5:20

    13、00. This European Standard is to be read in conjunction with EN 50121-1. This standard forms Part 5 of the European Standard series EN 50121, published under the general title Railway applications - Electromagnetic compatibility. The series consists of Part 1 : General Part 2 : Emission of the whole

    14、 railway system to the outside world Part 3-1 : Rolling stock - Train and complete vehicle Part 3-2 : Rolling stock - Apparatus Part 4 : Emission and immunity of the signalling and telecommunications apparatus Part 5 : Emission and immunity of fixed power supply installations and apparatus The follo

    15、wing dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-07-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2009-07-01 This European Stand

    16、ard has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association and covers essential requirements of EC Directive 89/336/EEC. See Annex ZZ. _ 2 Contents Introduction.4 1 Scope .4 2 Normative references.5 3 Definitions.6 4 Performance criteria

    17、.6 5 Emission tests and limits.6 5.1 Emission from the substation to the outside world.6 5.2 Emission test for apparatus operating at less than 1 000 V r.m.s. a.c.7 5.3 Emission values within the boundary of the substation.7 6 Immunity tests and limits.7 7 Fixed power supplies on railway property wh

    18、ich are not used for railway traction purposes .7 Annex A (informative) Emission within the boundary of the substation for normal operation and during the operation of switches.14 Annex ZZ (informative) Coverage of Essential Requirements of EC Directives .17 Bibliography .18 Figures Figure A.1 Emiss

    19、ion from switches Peak .15 Figure A.2 Emission within substation boundary Peak.16 Tables Table 1 Immunity Enclosure port.9 Table 2 Immunity Ports for signal lines and data buses not involved in process control.10 Table 3 Immunity Ports for process, measurement and control lines, and long bus and con

    20、trol lines .11 Table 4 Immunity D.C. input and d. c. output power ports .12 Table 5 Immunity A.C. input and a.c. output power ports.13 Table 6 Immunity Earth port .13 3 Introduction The requirements of this standard have been specified so as to ensure a level of electromagnetic emission which will c

    21、ause minimal disturbance to other equipment. The levels, however, do not cover the following cases: a) where the probability of an occurrence likely to produce emissions in excess of those which would normally be experienced is extremely low, b) where highly susceptible apparatus will be used in clo

    22、se proximity of the equipment covered by this standard, in which case further measures may have to be taken. The emission limits given are on the basis that the equipment of the product family range is installed in railway substation areas. 1 Scope This European Standard applies to emission and immu

    23、nity aspects of EMC for electrical and electronic apparatus and systems intended for use in railway fixed installations associated with power supply. This includes the power feed to the apparatus, the apparatus itself with its protective control circuits, trackside items such as switching stations,

    24、power autotransformers, booster transformers, substation power switchgear and power switchgear to other longitudinal and local supplies. Filters operating at railway system voltage (for example, for harmonic suppression or power factor correction) are not included in this standard since each site ha

    25、s special requirements. Filters would normally have separate enclosures with separate rules for access. If electromagnetic limits are required, these will appear in the specification for the equipment. The limits in this standard do not apply to intentional communication signals. The frequency range

    26、 considered is from d.c. to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified. Emission and immunity limits are given for items of apparatus which are situated: a) within the boundary of a substation which delivers electric power to a railway; b) beside t

    27、he track for the purpose of controlling or regulating the railway power supply, including power factor correction and filtering; c) along the track for the purpose of supplying electrical power to the railway other than by means of the conductors used for contact current collection, and associated r

    28、eturn conductors. Included are high voltage feeder systems within the boundary of the railway which supply substations at which the voltage is reduced to the railway system voltage. NOTE 1 Examples are one conductor of a 25-0-25 kV 50 Hz system and the 110 kV 16,7 Hz supply systems. NOTE 2 Similar c

    29、onductors which are outside the railway boundary are treated as in the public area and are considered to be general overhead power lines although they feed only the railway. d) beside the track for controlling or regulating electric power supplies to ancillary railway uses. This category includes po

    30、wer supplies to marshalling yards, maintenance depots and stations; e) various other non-traction power supplies from railway sources which are shared with railway traction. Apparatus and systems which are in an environment which can be described as residential, commercial or light industry, even wh

    31、en placed within the physical boundary of the railway substation, shall comply with the relevant generic European EMC standard. 4 Excluded from the immunity requirements of this standard is power supply apparatus which is intrinsically immune to the tests defined in Tables 1 to 6 of this standard. N

    32、OTE 3 An example is an 18 MVA 230 kV to 25 kV power supply transformer. These specific provisions are to be used in conjunction with the general provisions in EN 50121-1. This part of the standard covers requirements for both apparatus and fixed installations. The sections for fixed installations ar

    33、e not relevant for CE marking. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) appl

    34、ies. EN 50121-1 Railway applications Electromagnetic compatibility Part 1: General EN 50121-2 Railway applications Electromagnetic compatibility Part 2: Emission of the whole railway system to the outside world EN 55016-1-1 Specification for radio disturbance and immunity measuring apparatus and met

    35、hods Part 1-1: Radio disturbance and immunity measuring apparatus Measuring apparatus (CISPR 16-1-1) EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of measurement (CISPR 22, mod.) EN 61000-3-2 Electromagnetic compatibility (EMC) Part 3-2: Limits Limits

    36、 for harmonic current emissions (equipment input current up to and including 16 A per phase) (IEC 61000-3-2) EN 61000-3-3 Electromagnetic compatibility (EMC) Part 3-3: Limits Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rate

    37、d current 16 A per phase and not subject to conditional connection (IEC 61000-3-3) EN 61000-4-2 Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques Electrostatic discharge immunity test (IEC 61000-4-2) EN 61000-4-3 Electromagnetic compatibility (EMC) Part 4-3: Testing an

    38、d measurement techniques Radiated, radio-frequency, electromagnetic field immunity test (IEC 61000-4-3) EN 61000-4-4 Electromagnetic compatibility (EMC) Part 4-4: Testing and measurement techniques Electrical fast transient/burst immunity test (IEC 61000-4-4) EN 61000-4-5 Electromagnetic compatibili

    39、ty (EMC) Part 4-5: Testing and measurement techniques Surge immunity test (IEC 61000-4-5) EN 61000-4-6 Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques Immunity to conducted disturbances, induced by radio-frequency fields (IEC 61000-4-6) EN 61000-4-8 Electromagnetic c

    40、ompatibility (EMC) Part 4-8: Testing and measurement techniques Power frequency magnetic field immunity test (IEC 61000-4-8) EN 61000-4-12 Electromagnetic compatibility (EMC) Part 4-12: Testing and measurement techniques Oscillatory waves immunity test (IEC 61000-4-12) 5 EN 61000-6-2 Electromagnetic

    41、 compatibility (EMC) Part 6-2: Generic standards Immunity for industrial environments (IEC 61000-6-2) EN 61000-6-4 Electromagnetic compatibility (EMC) Part 6-4: Generic standards Emission standard for industrial environments (IEC 61000-6-4, mod.) 3 Definitions For the purpose of this Part 5 of the E

    42、uropean Standard the following definitions apply. 3.1 apparatus electric or electronic product with an intrinsic function intended for implementation into a fixed railway installation. 3.2 environment surrounding objects or region which may influence the behaviour of the system and or may be influenced by the system 3.3 external interface boundary where a system interacts with any other or where a system interacts with its environment 3.4 railway substation installation, the main function of which is to sup


    注意事项

    本文(BS EN 50121-5-2006 铁路设施.电磁兼容性.固定供电设备的辐射和抗干扰.pdf)为本站会员(花仙子)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开