欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    UL 913-2013 UL Standard for Safety Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I II and III Division 1 Hazardous (Classified) Locations (Eighth Edition R.pdf

    • 资源ID:1069045       资源大小:589.14KB        全文页数:24页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    UL 913-2013 UL Standard for Safety Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I II and III Division 1 Hazardous (Classified) Locations (Eighth Edition R.pdf

    1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 913 Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, and III, Division 1, Hazardous (Classied) LocationsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPROD

    2、UCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, and III, Division 1, Hazardous (Classie

    3、d) Locations, UL 913 Eighth Edition, Dated December 6, 2013 Summary of Topics This revision to ANSI/UL 913 is being issued to include the following changes in requirements: Revisions to 7.1.2 and deletion of Table 7.1 per 2014 NEC Clarifying the issue of temperature classication for Class II and Cla

    4、ss III intrinsically safe apparatus for 9.3, 9.4 and 10.1 Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effective date

    5、 note indicating the date of publication or the date on which the changed requirement becomes effective. The revised requirements are substantially in accordance with Proposal(s) on this subject dated May 1, 2015 and August 28, 2015. All rights reserved. No part of this publication may be reproduced

    6、, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied w

    7、arranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, eve

    8、n if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defen

    9、d, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. THE STANDARDS TECHN

    10、ICAL PANEL FOR UL 913 HAS DETERMINED THAT AS OF SEPTEMBER 1, 2018, EDITION 5 AND EDITION 7 OF UL 913 WILL BE WITHDRAWN AND MAY BE USED TO DETERMINE A PRODUCTS COMPLIANCE UNTIL THIS DATE. The following table summarizes the active editions of UL 913, and lists the established withdrawal date for each

    11、edition of this standard. OCTOBER 16, 2015 UL 913 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Standard Edition Status of Edition (Active/Withdrawn) Established Withdrawal Date for Each Standard Edition 5 Active September 1, 2018 7 Act

    12、ive September 1, 2018 8 Active Active until further notice Note: These editions may be used to determine compliance for new or modied products until the dates shown. When the Standards Technical Panel has determined that all existing products shall be upgraded and assessed for compliance with a new

    13、standard edition, the edition number will be noted with an “*” in this table. OCTOBER 16, 2015 UL 913 tr2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 6, 2013 (Title Page Reprinted: October 16, 2015) 1 UL 913 Standard for Intrinsi

    14、cally Safe Apparatus and Associated Apparatus for Use in Class I, II, III, Division 1, Hazardous (Classied) Locations The First edition was titled Standard for Intrinsically Safe Electrical Equipment for Use in Hazardous Locations. The Second edition was titled Standard for Intrinsically Safe Electr

    15、ical Circuits and Apparatus for Use in Hazardous Locations and its Associated Apparatus. First Edition November, 1971 Second Edition January, 1976 Third Edition July, 1979 Fourth Edition July, 1988 Fifth Edition February, 1997 Sixth Edition August, 2002 Seventh Edition July, 2006 Eighth Edition Dece

    16、mber 6, 2013 This ANSI/UL Standard for Safety consists of the Eighth Edition including revisions through October 16, 2015. The most recent designation of ANSI/UL 913 as an American National Standard (ANSI) occurred on October 16, 2015. ANSI approval for a standard does not include the Cover Page, Tr

    17、ansmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standar

    18、ds for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIE

    19、S INC. ANSI/UL 913-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 6, 2013 UL 913 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUC

    20、TION 1 Scope .4 2 Undated References 4 3 Unit of Measurement .5 4 Components .5 5 General 5 6 Zone Equivalency .6 6.1 General 6 6.2 Zone 20, Group IIIA 6 6.3 Zone 20, Group IIIB 6 6.4 Zone 20, Group IIIC 7 7 Apparatus For Class II And Class III Locations .7 7.1 General 7 7.2 Dust-tight enclosures 8

    21、8 Dust-Tight Enclosure Test .8 9 Dust Blanketing Temperature Test .9 MARKING 10 General 10 11 Zone Equivalency Markings .12 11.1 Zone 20, Group IIIA 12 11.2 Zone 20, Group IIIB 13 11.3 Zone 20, Group IIIC 13 APPENDIX A EXPLANATORY MATERIAL A1 Scope .A1 A6 Apparatus For Class II And Class III Locatio

    22、ns A1 APPENDIX B Reference Standards.B1 DECEMBER 6, 2013 UL 913 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION NOTICE: An asterisk (*) following the number or letter designating a paragraph indicates explanatory material on th

    23、at paragraph can be found in Appendix A. 1 Scope 1.1 * These requirements apply to apparatus or parts of apparatus for installation and use in Class I, II, or III, Division 1 hazardous (classied) locations in accordance with the requirements of the National Electrical Code, NFPA 70. 1.2 These requir

    24、ements also apply to apparatus or parts of apparatus for installation and use in Zone 20, Groups IIIA, IIIB, and IIIC hazardous (classied) locations in accordance with the requirements of the National Electrical Code, NFPA 70. 1.3 * These requirements also cover associated apparatus located outside

    25、of the hazardous (classied) location whose design and construction may inuence the intrinsic safety of an electrical circuit within the hazardous (classied) location. 1.4 These requirements are based on consideration of ignition in locations classied as a hazardous location by the presence of ammabl

    26、e or combustible material under normal atmospheric conditions. 1.5 * For the purposes of this standard, normal atmospheric conditions are considered to be: a) An ambient temperature of 40C (104F); b) An oxygen concentration not greater than 21 percent by volume; and c) A pressure of one atmosphere.

    27、1.6 This standard does not cover apparatus based on high voltage electrostatic principles such as electrostatic paint spraying. 2 Undated References 2.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition

    28、of that code or standard. DECEMBER 6, 2013 UL 913 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3 Unit of Measurement 3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate informat

    29、ion. 4 Components 4.1 Except as indicated in 4.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix B for a list of standards covering components generally used in the products covered by this standard. 4.2 A component is not requir

    30、ed to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 4.3 A component shall be used in accordance with its rating establishe

    31、d for the intended conditions of use. 4.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under t

    32、hose specic conditions. 5 General 5.1 The purpose of this standard is to provide requirements for the construction and testing of electrical apparatus, or parts of such apparatus, having circuits that are not capable of causing ignition in Division 1 Hazardous (Classied) Locations as dened in Articl

    33、e 500 of the National Electrical Code, ANSI/NFPA 70. 5.2 This standard is not to be considered an instruction manual for untrained persons. It is intended to promote uniformity of practice among those skilled in the eld of intrinsic safety. 5.3 Except where modied by the requirements of this standar

    34、d, intrinsically safe and associated apparatus shall comply with the applicable requirements for unclassied (ordinary) locations. 5.4 Enclosures for associated apparatus shall conform to the requirements of the location in which they are intended to be installed. 5.5 Apparatus for Class I, Division

    35、1, Groups A and/or B locations, shall comply with all the applicable requirements in UL 60079-0:2013 and UL 60079-11:2013 for Group IIC, level of protection ia . Exception: Marking of the apparatus shall meet the requirements of Section 10. DECEMBER 6, 2013 UL 913 5UL COPYRIGHTED MATERIAL NOT AUTHOR

    36、IZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 5.6 Apparatus for Class I, Division 1, Group C locations, shall comply with all the applicable requirements in UL 60079-0:2013 and UL 60079-11:2013 for Group IIB, level of protection ia . Exception: Marking of the apparatus sha

    37、ll meet the requirements of Section 10. 5.7 Apparatus for Class I, Division 1, Group D locations, shall comply with all the applicable requirements in UL 60079-0:2013 and UL 60079-11:2013 for Group IIA, level of protection ia . Exception: Marking of the apparatus shall meet the requirements of Secti

    38、on 10. 6 Zone Equivalency 6.1 General 6.1.1 The following Zone equivalency details address Class II, Division 1 and Class III intrinsically safe and associated apparatus for installation and use in Zone 20 hazardous (classied) locations in accordance with the requirements of the National Electrical

    39、Code, NFPA 70. 6.1.2 Similar Zone equivalency details for Class I, Division 1 intrinsically safe and associated apparatus for installation and use in Class I, Zone 0 hazardous (classied) locations is not included. Based on the reference to UL 60079-11 and UL 60079-0 in this standard, Class I, Divisi

    40、on 1 intrinsically safe and associated apparatus that complies with the requirements in this standard can additionally or alternatively be marked in accordance with UL 60079-11 and UL 60079-0. 6.2 Zone 20, Group IIIA 6.2.1 Intrinsically safe and associated apparatus intended to be marked in accordan

    41、ce with 11.1 shall comply with all the applicable requirements for Class III hazardous (classied) locations as applicable. 6.3 Zone 20, Group IIIB 6.3.1 Intrinsically safe and associated apparatus intended to be marked in accordance with 11.2 shall comply with all the applicable requirements for Cla

    42、ss II, Group F, Group G or both Groups F and G hazardous (classied) locations as applicable. DECEMBER 6, 2013 UL 913 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 6.4 Zone 20, Group IIIC 6.4.1 Intrinsically safe and associated apparatus i

    43、ntended to be marked in accordance with 11.3 shall comply with all the applicable requirements for Class II, Group E hazardous (classied) locations as applicable. 7 Apparatus For Class II And Class III Locations 7.1 General 7.1.1 Intrinsically safe apparatus and associated wiring for Class II and Cl

    44、ass III locations shall comply with the requirements in Sections15i nthis standard, as applicable and shall also comply with the requirements of 7.1.2 and either 7.1.3 or 7.1.4. 7.1.2 * The temperature of exposed surfaces of apparatus shall be determined when tested according to the procedures descr

    45、ibed in 9.1 9.3. For this requirement, exposed means exposed to the ammable or combustible atmosphere or material. Parts within a dust-tight enclosure are not considered exposed; the outside surfaces of the enclosure are exposed. Exception: Temperatures of small components under fault conditions sha

    46、ll be permitted to exceed these limits if it is shown by test that such higher temperatures will not result in ignition or charring. Table 7.1 Maximum apparatus surface temperatures Table 7.1 deleted 7.1.3 Except as specied in 7.1.4, intrinsically safe apparatus for use in Class II, Groups E, F, and

    47、 G locations shall be enclosed in a dust-tight enclosure that complies with the requirements in 7.2.1 7.2.3. In addition, the apparatus shall also comply with the spark ignition requirements for Class I, Group D or for methane. See 5.7. 7.1.4 * Intrinsically safe apparatus for use in Class II, Group

    48、s E, F, and G locations not enclosed in a dust-tight enclosure complying with the requirements in 7.2.1 7.2.3 shall comply with the spark ignition requirements specied in 7.1.3. In this case, it is to be assumed that all spacings do not comply with the separation distance requirements specied in UL

    49、60079-11:2013 and that all connections between live or grounded parts and conductors are in the most unfavorable condition. The number of such connections is unlimited. Exception: Intrinsically safe apparatus for use in Class II, Group E locations need not be enclosed in a dust-tight enclosure complying with the requirements in 7.2.1 7.2.3 when the apparatus complies with the UL 60079-11:2013 requirements for total immersion, or uncontrolled dust layer thickness. OCTOBER 1


    注意事项

    本文(UL 913-2013 UL Standard for Safety Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I II and III Division 1 Hazardous (Classified) Locations (Eighth Edition R.pdf)为本站会员(twoload295)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!