欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    UL 61010-031 (ND)-2017 National Differences For Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 031 Safety Requirements for Hand-Heldan.pdf

    • 资源ID:1068633       资源大小:54.67KB        全文页数:6页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    UL 61010-031 (ND)-2017 National Differences For Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 031 Safety Requirements for Hand-Heldan.pdf

    1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForSafety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use Part 031: Safety Requirements for Hand-Held Probe Assemblies for Electrical Measur

    2、ement andTestUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForSafety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use Part 031:Safety Requirements for Hand-Held Probe Assemblies for Elect

    3、rical Measurement and TestSecond EditionEdition Date: January 27, 2017Adoption of the Second Edition of UL 61010-031, Standard for Safety Requirements for ElectricalEquipment for Measurement, Control and Laboratory Use Part 031: Safety Requirements forHand-Held Probe Assemblies for Electrical Measur

    4、ement and TestUL 61010-031 is an adoption of IEC 61010-031, Safety Requirements for Electrical Equipment forMeasurement, Control and Laboratory Use Part 031: Safety Requirements for Hand-Held ProbeAssemblies for Electrical Measurement and Test, (second edition issued May 2015). Please notethat the N

    5、ational Difference document incorporates all of the US National Differences for UL61010-031.As noted in the Commitment for Amendments statement located on the back side of the titlepage, UL and CSA are committed to updating this bi-national standard jointly.This document provides a single listing of

    6、 the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior p

    7、ermission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or

    8、 similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for

    9、any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reas

    10、onableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2017 Underwriters Laboratories Inc.JANUARY 27, 2017NATIONAL DIFFERENCES FOR2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCT

    11、ION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type, andth

    12、ese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are deviatio

    13、ns based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted until a partic

    14、ularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference entails. T

    15、ypically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table, figure,or annex. Addition is not meant to include adding select words to th

    16、e base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause, table,figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as the addition,replacement or deletion of ce

    17、rtain words or the replacement of an entire clause, subclause, table, figure,or annex of the base IEC text.JANUARY 27, 2017 NATIONAL DIFFERENCES FOR 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1.4.3DV DR Addition of th

    18、e following clause referencing the National Electrical Codeand the Canadian Electrical Code:This standard applies to equipment:a) To be employed in accordance with ANSI/NFPA 70, National Electrical Code(NEC);b) Designed to comply with the general requirements of CAN/CSA-C22.2 No. 0and to be installe

    19、d in accordance with the Canadian Electrical Code (CE Code),Part I, CSA C22.1; orc) Both (a) and (b).2DV DR Modification of Clause 2 to add the following reference publications:CSA C22.115, Canadian Electrical Code, Part ICAN/CSA-C22.2 No. 0-10 (R2015), General requirements Canadian Electrical Code,

    20、 Part IIANSI/NFPA 70, National Electrical Code (NEC)IEC 60664-3-2016, Insulation coordination for equipment within low-voltage systems Part 3: Useof coating, potting or moulding for protection against pollutionUL 746E Standard for Polymeric Materials Industrial Laminates, Filament Wound Tubing,Vulca

    21、nized Fibre, and Materials Used in Printed Wiring Boards6.5.1.2.3DV D2 Modification of Clause 6.5.1.2.3, second paragraph by replacing it withthe following:CREEPAGE DISTANCES for POLLUTION DEGREE 1 are applied to coated printed wiring boards whosecoatings meet the requirements of IEC 60664-3 for typ

    22、e A coatings or UL 746E forconformal coatings.Table 10DV D2 Modification:Add the following new row of values for a CLEARANCE of 1,5 mm.JANUARY 27, 2017NATIONAL DIFFERENCES FOR4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULRequired CLEARANCE

    23、Impulse 1,2/50 s a.c. r.m.s. 50/60 Hz a.c. peak 50/60 Hz or d.c.mm V peak V V1,5 2 560 1 390 1 9708.4DV DE Modification of Clause 8.4, first paragraph, to replace with the following:The probe body is subjected to one impact against a 50 mm thick hardwood board havinga density of more than 700 kg/m3f

    24、ixed to a solid wall, when swinging as a pendulum by itsPROBE WIRE (see Figure 21). The height of the drop is 2 m, or the PROBE WIRE length if shorter.12.1DV D2 Modification by adding the following as the first paragraph of Clause 12.1:Where safety is involved, components shall comply with applicabl

    25、e safety requirementsspecified in relevant ANSI, CAN, CSA, IEC, ISO, or UL standards, as appropriate.JANUARY 27, 2017 NATIONAL DIFFERENCES FOR 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJANUARY 27, 2017NATIONAL DIFFERENCES FOR6No Text on This Page


    注意事项

    本文(UL 61010-031 (ND)-2017 National Differences For Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 031 Safety Requirements for Hand-Heldan.pdf)为本站会员(sumcourage256)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开