欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    UL 555C-2014 UL Standard for Safety Ceiling Dampers (Fourth Edition Reprint with Revisions Through and Including May 1 2017)《天花板防火阀》.pdf

    • 资源ID:1068302       资源大小:621.12KB        全文页数:22页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    UL 555C-2014 UL Standard for Safety Ceiling Dampers (Fourth Edition Reprint with Revisions Through and Including May 1 2017)《天花板防火阀》.pdf

    1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 555C Ceiling DampersUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION

    2、OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Ceiling Dampers, UL 555C Fourth Edition, Dated December 16, 2014 Summary of Topics The Fourth Edition of the Standard for Safety for Ceiling Dampers, UL 555C, has been issued to reect the reaffirmation of the ANSI approval. No cha

    3、nges in requirements have been made. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is

    4、 without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings,

    5、loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardles

    6、s of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced w

    7、hile purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the af

    8、fected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. DECEMBER 16, 2014 UL 555C tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION

    9、 WITHOUT PERMISSION FROM UL DECEMBER 16, 2014 UL 555C tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL December 16, 2014 1 UL 555C Standard for Ceiling Dampers Prior to the rst edition, the requirements for the product

    10、s covered by this standard were included in the Third Edition of UL 555 titled Fire Dampers and Ceiling Dampers. First Edition December, 1992 Second Edition December, 1996 Third Edition October, 2006 Fourth Edition December 16, 2014 This ANSI/UL Standard for Safety consists of the Fourth Edition. Th

    11、e most recent designation of ANSI/UL 555C as an American National Standard (ANSI) occurred on December 16, 2014. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard

    12、 may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All

    13、of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2014 UNDERWRITERS LABORATORIES INC. ANSI/UL 555C-2010 (R2014)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PER

    14、MISSION FROM UL DECEMBER 16, 2014 CEILING DAMPERS - UL 555C 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 General 5 2.1 Components .5 2.2 Units of measurement .5 2.3 Undated referenc

    15、es .5 CONSTRUCTION 3 Components 5 4 Corrosion Protection .5 PERFORMANCE 5 General 6 6 Fire Endurance Test .7 6.1 Test assembly .7 6.2 Conditioning of test specimen 9 6.3 Time-temperature curve .9 6.4 Furnace pressure .12 6.5 Concealed space temperatures .13 6.6 Conduct of re test 13 6.7 Conditions o

    16、f acceptance .14 7 Closing Reliability Test .14 8 Salt-Spray Exposure Test .14 9 Spring Closing Force Test 15 10 Dynamic Closure Test .15 10.1 General .15 10.2 Method .16 11 Reports of Results 17 MANUFACTURERS INSTRUCTIONS 12 Installation Instructions 18 MARKING 13 General 18 DECEMBER 16, 2014 CEILI

    17、NG DAMPERS - UL 555C 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements and methods of tests apply to ceiling dampers and ceiling air diffusers intended for installation in hourly rated re resistive

    18、oor-ceiling and roof-ceiling assemblies. Fire resistive assemblies are investigated in accordance with the Standard for Fire Tests of Building Construction and Materials, UL 263. 1.2 Ceiling dampers are intended for use in sheet metal air duct outlets which penetrate the ceilings of hourly-rated re

    19、resistive assemblies. Ceiling air diffusers are intended for use with Class 0 and Class 1 air duct connectors, or for ductless installation in the ceilings of hourly rated re resistive assemblies. Ceiling dampers and ceiling air diffusers are designed for use as alternatives to previously tested hin

    20、ged-door sheet metal type dampers installed at the bottom of sheet metal air ducts over each duct outlet. Ceiling dampers and ceiling air diffusers intended for installation in other types of re resistive assemblies, such as assemblies without penetrations, are investigated in accordance with the St

    21、andard for Fire Tests of Building Construction and Materials, UL 263, in place of the Fire Endurance Test, Section 6, described in this standard. 1.3 The investigation of ceiling dampers and ceiling air diffusers for use in oor/ceiling assemblies previously rated with a hinged-door sheet metal dampe

    22、r involves a comparison of the re resistance performance of the ceiling damper or ceiling air diffuser with that of a hinged-door sheet metal damper. This is done to conrm that the substitution of the ceiling damper or ceiling air diffuser does not reduce the hourly re endurance rating of an assembl

    23、y previously rated with the hinged-door type damper. Ceiling dampers and ceiling air diffusers for use in oor/ceiling assemblies not previously rated with a hinged-door sheet metal damper shall be tested as a component of the proposed oor/ceiling assembly in accordance with the Standard for Fire Tes

    24、ts of Building Construction and Materials, UL 263. Ceiling dampers and ceiling air diffusers are not assigned hourly ratings, but rather are assembly components designated for use in specic hourly rated re resistive assemblies incorporating air duct outlets penetrating protective ceilings. 1.4 The r

    25、e performance measured by ANSI/UL 263 is based upon air movement being stopped at the start of a re. Ceiling dampers and ceiling air diffusers intended for use in HVAC systems where the airow is operational at the time of a re, such as in a smoke control system, or from other situations in which the

    26、 fan system is operational at the time of a re are investigated for dynamic closure. Ceiling dampers and ceiling air diffusers intended for use where the air movement is effectively stopped at the start of a re are not required to be investigated for dynamic closure. 1.5 Tests conducted in accordanc

    27、e with the test methods described herein are intended to develop data to enable regulatory authorities to determine the acceptability of ceiling dampers and ceiling air diffusers for use in oor-ceiling and roof-ceiling assemblies having hourly re endurance ratings of the specied or shorter duration.

    28、 DECEMBER 16, 2014 CEILING DAMPERS - UL 555C 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2 General 2.1 Components 2.1.1 A component of a product covered by these requirements shall comply with the requirements for that component and sha

    29、ll be used in accordance with its recognized rating established for the intended conditions. 2.1.2 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not

    30、 exceeding specied limits, and shall be used only under those specic conditions. 2.2 Units of measurement 2.2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 2.3 Undated references 2.3.1 Any undated reference to a code or sta

    31、ndard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. CONSTRUCTION 3 Components 3.1 The load on a heat responsive link used in a ceiling damper or ceiling air diffuser shall be within the design load limits of the heat

    32、responsive link. 3.2 Component springs used in a ceiling damper or ceiling air diffuser shall be of a material having spring properties equivalent to stainless steel conforming to the Standard Specication for Stainless Steel Spring Wire, ASTM A313. 4 Corrosion Protection 4.1 A ferrous metal part use

    33、d in the ceiling damper or ceiling air diffuser shall be one of the 300 Series of stainless steel or shall have one of the following corrosion-protection systems: a) A hot-dipped mill galvanized coating complying with the coating Designation G60 or A60 in the Weight (Mass) of Coating requirements ta

    34、ble in the Standard Specication for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process, ASTM A653, with not less than 40% of the zinc on any side, based on the minimum single spot test requirement in this ASTM Designation. The weight of the zinc coa

    35、ting is to be established in accordance with the Standard Test Method for Weight (Mass) of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy Coatings, ASTM A90. An A60 (alloyed) coating shall also comply with the requirements of 4.4. b) A zinc coating, other than that provided on hot-dipped

    36、 mill galvanized sheet steel, uniformly applied to an average thickness of not less than 0.41 mils (10.41 microns) on each surface with a minimum thickness of 0.34 mils (8.64 microns). The thickness of the coating is to be established in accordance with the test method in the Standard Guide for Meas

    37、urement of Electrodeposited Metallic Coating Thicknesses by the Dropping Test, ASTM B555. An annealed coating shall also comply with the requirements of 4.4. DECEMBER 16, 2014 CEILING DAMPERS - UL 555C 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSIO

    38、N FROM UL c) A cadmium coating not less than 0.5 mils (12.7 microns) thick on both surfaces. The thickness of coating is to be established in accordance with the test method in the Standard Guide for Measurement of Electrodeposited Metallic Coating Thicknesses by the Dropping Test, ASTM B555. d) Two

    39、 coats of an organic nish of the epoxy or alkyd-resin type or other outdoor paint on each surface. The acceptability of the paint is to be determined by its composition or by corrosion tests, as specied in the Standard for Organic Coatings for Steel Enclosures for Outdoor Use Electrical Equipment, U

    40、L 1332. 4.2 Coated or uncoated metals used in the assembly of ceiling dampers or ceiling air diffusers shall be galvanically compatible. 4.3 Component springs and bearings used in the assembly of ceiling dampers or ceiling air diffusers shall be of material having resistance to atmospheric corrosion

    41、 equivalent to brass or bronze. 4.4 A hot-dipped mill galvanized A60 (alloyed) coating or an annealed zinc coating that is bent or similarly formed after annealing and that is not otherwise required to be painted shall be painted in the bent or formed area as specied in 4.1(d) when the bending or fo

    42、rming process damages the zinc coating as described in 4.5. 4.5 When aking or cracking of the zinc coating at the outside radius of the bent or formed section is visible at 25 power magnication, the zinc coating is to be considered damaged. Simple sheared or cut edges and punched holes are not to be

    43、 dened as formed. Extruded edges and rolled edges and holes shall comply with 4.4. PERFORMANCE 5 General 5.1 Representative samples of each size, style, and arrangement of ceiling dampers or ceiling air diffusers shall be subjected to the tests specied in Table 5.1. The representative sample sizes s

    44、hall be determined on the basis of maximum ceiling damper or ceiling air diffuser size and most critical closing force condition. DECEMBER 16, 2014 CEILING DAMPERS - UL 555C 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Table 5.1 Tests fo

    45、r ceiling dampers and ceiling air diffusers Test Sections Approved for: Static Systems Dynamic Systems Gravity-operated Spring-operated Gravity-operated Spring-operated 1. Fire Endurance Test a 6XXXX 2. Closing Reliability 7XXXX 3. Salt-Spray Exposure 8XXXX 4. Spring Closing Force 9XX 5. Dynamic Clo

    46、sure 10 X X X Test applicable Test not applicable a The Fire Endurance Test described in this standard applies to ceiling dampers and ceiling air diffusers being evaluated for use in oor/ceiling assemblies previously tested with a hinged door sheet-metal damper. Ceiling dampers and ceiling air diffu

    47、sers intended for use in oor/ceiling assemblies not previously tested with a hinged door sheet-metal damper shall be evaluated to the requirements of the Standard for Fire Tests of Building Construction and Materials, UL 263. 6 Fire Endurance Test 6.1 Test assembly 6.1.1 The ceiling damper or ceilin

    48、g air diffuser shall be installed in a ceiling of a type previously tested in a rated re resistive oor-ceiling or roof-ceiling assembly. Each test assembly shall include a reference hinged-door type damper installed in a oor-ceiling test construction identical to that used with the ceiling damper or

    49、 ceiling air diffuser installation. The ceiling compartments containing the reference hinged-door damper and the ceiling damper or ceiling air diffuser shall be separated by means of an insulated wall or barrier to prevent heat transfer from one ceiling compartment to the other during the re test. 6.1.2 The duct outlet provided with the reference hinged-door damper is to be representative of the smallest duct outlet size for which comparative performance data is desired. The compar


    注意事项

    本文(UL 555C-2014 UL Standard for Safety Ceiling Dampers (Fourth Edition Reprint with Revisions Through and Including May 1 2017)《天花板防火阀》.pdf)为本站会员(eveningprove235)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开