    UL 2196-2017 UL Standard for Safety Fire Test for Circuit Integrity of Fire-Resistive Power Instrumentation Control and Data Cables (Second Edition).pdf

    • 资源ID:1067845       资源大小:834.30KB        全文页数:39页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    UL 2196-2017 UL Standard for Safety Fire Test for Circuit Integrity of Fire-Resistive Power Instrumentation Control and Data Cables (Second Edition).pdf

    1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 2196 Standard for Fire Test for Circuit Integrity of Fire-Resistive Power, Instrumentation, Control and Data Cables STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPR

    2、ODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Standard for Fire Test for Circuit Integrity of Fire-Resistive Power, Instrumentation, Control and Data Cables, UL

    3、2196 Second Edition, Dated August 29, 2017 Summary of Topics This new edition of ANSI/UL 2196 contains identical requirements to the Third Edition of CAN/ULC-S139 use in Canada. There are some requirements that are unique to one country or the other and these have been identied as country-specic. Th

    4、e new requirements are substantially in accordance with Proposal(s) on this subject dated September 23, 2016. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or

    5、otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequent

    6、ial, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liabili

    7、ty for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reas

    8、onable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. AUGUST 29, 2017 UL 2196 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 29

    9、, 2017 UL 2196 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Prepared by: ULC Standards CAN/ULC-S139 Third Edition Underwriters Laboratories Inc. ANSI/UL 2196 Second Edition Standard for Fire Test for Circuit Integr

    10、ity of Fire-Resistive Power, Instrumentation, Control, and Data Cables August 29, 2017 Approved by: ANSI/UL 2196-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This Standard is issued jointly by Underwriters La

    11、boratories Inc. (UL) and ULC Standards. Amendments to this Standard will be made only after processing according to the Standards writing procedures by UL and ULC Standards. UL and ULC Standards are separate and independent entities and each is solely responsible for its operations and business acti

    12、vities. The UL trade names and trademarks depicted in this document are the sole property of Underwriters Laboratories Inc. The ULC Standards trade names and trademarks depicted in this document are the sole property of ULC Standards. ISSN 0317-526X Copyright 2017 ULC Standards All rights reserved.

    13、No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, whatsoever without the prior permission of the publisher. In Canada, written comments are to be sent to the ULC Standards, 400 - 171 Nepean Street, Ottawa, Ontario K2P 0B4. Proposals should be

    14、submitted on a Standards Revision Request Form available from ULC Standards. Copyright 2017 Underwriters Laboratories Inc. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, owners

    15、hips, and rights regarding those Standards shall remain the sole and exclusive property of UL. This ANSI/UL Standard for Safety consists of the Second Edition including revisions through August 29, 2017. The most recent designation of ANSI/UL 2196 as an American National Standard (ANSI) occurred on

    16、August 29, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page (front and back), or the Preface. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in U

    17、Ls On-Line Collaborative Standards Development System (CSDS) at https:/. To purchase UL Standards, visit ULs Standards Sales Site at http:/ HowToOrder.aspx or call toll-free 1-888-853-3503.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONT

    18、ENTS Preface .4 1 Scope .5 2 Units of Measurement .6 3 REFERENCE PUBLICATIONS .6 4 GLOSSARY 6 5 TESTS 7 5.1 FIRE TESTS .7 5.2 HOSE STREAM TEST 18 5.3 TENSILE STRENGTH TEST .18 6 CONDITIONS OF ACCEPTANCE .19 6.1 DETERMINATION OF CIRCUIT INTEGRITY .19 6.2 HOSE STREAM TEST 19 6.3 TENSILE STRENGTH TEST1

    19、9 7 REPORT .19 7.1 RESULTS 19 8 MARKINGS .20 9 INSTALLATION INSTRUCTIONS 21 TABLES TABLES21 FIGURES FIGURES .22 ANNEX A (NORMATIVE) REFERENCE PUBLICATIONS ANNEX B (NORMATIVE) SAMPLE SELECTION B1 ADDITIONAL INFORMATION ON SAMPLE SELECTION .31 ANNEX C (NORMATIVE) TESTING OF CIRCUIT INTEGRITY (CI) CABL

    20、E FOR USE IN THE UNITED STATES C1 TESTING OF FREE AIR INSTALLATION CIRCUIT INTEGRITY (CI) CABLE 32 C1.1 General .32 C1.2 Test assembly .32 C1.3 Hose stream 32 C1.4 Markings 33 ANNEX D (INFORMATIVE) HIGHER INTENSITY EXPOSURES D1 ADDITIONAL INFORMATION ON USE OF HIGHER INTENSITY EXPOSURES .34 AUGUST 2

    21、9, 2017 CAN/ULC-S139 ANSI/UL 2196 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Preface This is the common UL and ULC Standard for Fire Test for Circuit Integrity of Fire-Resistive Power, Instrumentation, Control and Data Cables. It is th

    22、e Third edition of CAN/ULC-S139, and the Second edition of ANSI/UL 2196. This common Standard was prepared by Underwriters Laboratories Inc., ULC Standards, and the Joint UL/ ULC Task Group on Integrity of Cables. The efforts and support of the Joint Task Group are gratefully acknowledged. This Stan

    23、dard was formally approved by the ULC Standards Committee on Fire Tests and UL Standard Technical Panel on Fire Resistive Cables. Only metric SI units of measurement are used in this Standard. If a value for measurement is followed by a value in other units in parentheses, the second value may be ap

    24、proximate. The rst stated value is the requirement. In Canada, there are two official languages, English and French. All safety warnings must be in French and English. Attention is drawn to the possibility that some Canadian authorities may require additional markings and/or installation instruction

    25、s to be in both official languages. This standard has been approved as a National Standard of Canada by the Standards Council of Canada. This standard has been approved by the American National Standards Institute as an American National Standard. Annexes A, B and C are identied as normative, forms

    26、mandatory parts of this Standard. Annex D is identied as informative, is for informational purposes only. Note: Although the intended primary application of this standard is stated in its scope, it is important to note that it remains the responsibility of the users of the standard to judge its suit

    27、ability for their particular purpose. Level of Harmonization This Standard is published as an identical standard between UL and ULC Standards. An identical standard is a standard that is the same in technical content except for conicts in Codes and Governmental Regulations. Presentation shall be wor

    28、d for word except for editorial changes. Interpretations The interpretation by the standards development organization of an identical or equivalent standard shall be based on the literal text to determine compliance with the standard in accordance with the procedural rules of the standards developme

    29、nt organization. If more than one interpretation of the literal text has been identied, a revision shall be proposed as soon as possible to each of the standards development organizations to more accurately reect the intent. UL Effective Date A UL effective date is established by Underwriters Labora

    30、tories Inc. and is not part of the ANSI approved standard. AUGUST 29, 2017 CAN/ULC-S139 ANSI/UL 2196 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 1 Scope 1.1 The intent of this Standard is to evaluate the integrity of power, control, ins

    31、trumentation, and data cables for their ability to maintain circuit integrity when subjected to standard re test exposure and associated hose stream test. 1.2 The power, control, instrumentation, and data cables covered by this Standard are intended to comply with the following requirements : In Can

    32、ada: Canadian Electrical Code and the National Building Code of Canada; In the United States: National Electrical Code, and/or the National Fire Alarm and Signaling Code, and/or the Standard for Fixed Guideway Transit and Passenger Rail Systems, and/or the Standard for Road Tunnels, Bridges, and Oth

    33、er Limited Access Highways. 1.3 Power, control, and instrumentation cables are subjected to the re exposure in accordance with CAN/ULC-S101, Standard Methods of Fire Endurance Tests of Building Construction and Materials, and ANSI/UL 263, Standard for Fire Tests of Building Construction and Material

    34、s. During the re test, cables are continuously energized at their maximum rated voltage or maximum utilization voltage (power cables); or at their maximum utilization voltage (control and instrumentation cables) and evaluated for circuit integrity. Insulation resistance measurements are also taken t

    35、o quantify leakage current. Following the re test, the assembly shall be subjected to a hose stream test. 1.4 Data cables are subjected to the re exposure in accordance with CAN/ULC-S101, Standard Methods of Fire Endurance Tests of Building Construction and Materials, and ANSI/UL 263, Standard for F

    36、ire Tests of Building Construction and Materials. During the re tests, the data cables are evaluated for their ability to maintain error free data transfer and retrieval at the specied protocol and data rates. Following the re test, the assembly shall be subjected to a hose stream test. 1.5 The re e

    37、xposure and hose stream tests are not intended to be representative of all re conditions and impact conditions, respectively. It is likely that conditions will vary with changes in the amount, nature, distribution of re loading, ventilation, compartment size and conguration, and heat conducting and

    38、dissipating characteristics of the compartment in which the cables are installed. These requirements provide a relative measure of re performance of comparable assemblies under these specied re exposure conditions. It is possible that any variation from the construction or operating condition tested

    39、, such as size, method of assembly and materials, will substantially change the performance characteristics of the cables. 1.6 The standardized re and hose stream exposures for comparing the performance of cables represents one factor in determining the acceptability of cables for use in specic appl

    40、ications. 1.7 The construction and operation of the furnace and the general test conditions are intended to be in accordance with the requirements in CAN/ULC S101, Standard Methods of Fire Endurance Tests of Building Construction and Materials, and ANSI/UL 263, Standard for Fire Tests of Building Co

    41、nstruction and Materials. AUGUST 29, 2017 CAN/ULC-S139 ANSI/UL 2196 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2 Units of Measurement 2.1 The metric unit shall be designated as the official unit for purposes of this standard. Where val

    42、ues of measurement are specied in both SI and English units, either unit is used. In cases of dispute, the metric unit shall be used. 3 REFERENCE PUBLICATIONS 3.1 See Annex A for a list of publications referenced in this standard. Any undated reference to a code or standard appearing in the requirem

    43、ents of this standard shall be interpreted as referring to the latest edition of that code or standard. When the latest edition of a standard is not applicable, the appropriate edition is indicated accordingly in Annex A. 4 GLOSSARY For the purpose of this Standard, the following denitions apply. 4.

    44、1 CABLE CONSTRUCTION A distinct design type as evidenced by number and size of conductors, conductor type, insulation type, shield type, and any individual insulation or overall jacket type, armor type, etc. 4.2 CABLE CONSTRUCTION FAMILY A distinct group of cable construction types that have similar

    45、 design features for a range of sizes and/or number of conductors all having the same circuit integrity rating. 4.3 CABLE TRAY A unit or assembly of units or sections and associated ttings forming a structural system used to securely fasten or support cables and raceways. 4.4 CIRCUIT INTEGRITY The a

    46、bility of a power, instrumentation, or control cable to maintain voltage and current to the load or the ability of a data cable to maintain error free data transfer and retrieval. 4.5 CIRCUIT INTEGRITY RATING The time period during which the cable or cable system continues to operate in its designat

    47、ed manner under specied re conditions and after the hose stream test for re-resistive cable or free air installation circuit integrity cable. 4.6 FIRESTOP SYSTEM A specic construction of materials intended to prevent the spread of re through an opening made in a re-resistive structure for passage of

    48、 penetrating items such as cables. 4.7 FIRE-RESISTIVE CABLE Power, control, instrumentation, or data cable in a system and evaluated in accordance with this Standard. 4.8 FREE AIR INSTALLATION CIRCUIT INTEGRITY CABLE Power, instrumentation, control or data cable in free air (no installed within a ra

    49、ceway) and evaluated in accordance with Annex C. 4.9 LOAD VOLTAGE (E applied ) The voltage applied between phase and ground to the cable that determine circuit integrity and insulation resistance. AUGUST 29, 2017 CAN/ULC-S139 ANSI/UL 2196 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 4.10 RACEWAY An enclosed channel of metallic or nonmetallic materials designed expressly for support and