欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    UL 1746-2007 UL Standard for Safety External Corrosion Protection Systems for Steel Underground Storage Tanks (Third Edition Reprint with Revisions Through and Including December 1_1.pdf

    • 资源ID:1067670       资源大小:565KB        全文页数:74页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    UL 1746-2007 UL Standard for Safety External Corrosion Protection Systems for Steel Underground Storage Tanks (Third Edition Reprint with Revisions Through and Including December 1_1.pdf

    1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1746 External Corrosion Protection Systems for Steel Underground Storage TanksUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COP

    2、YRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for External Corrosion Protection Systems for Steel Underground Storage Tanks, UL 1746 Third Edition, Dated January 17, 2007 Summary of Topics These revisions to the Standard f

    3、or External Corrosion Protection Systems for Steel Underground Storage Tanks, UL 1746, include the following: 1. Revisions to the scope section to clarify and update the requirements 2. Revisions to the glossary section to clarify, update, and provide consistency with other underground storage tank

    4、standards 3. Addition of a capacity and dimensions section and relocation of the requirements into this section 4. Revisions to the lift lug tests which includes the use of calculations for evaluating lift lugs 5. Deletion of abrasion test 6. Alternative to Lift Lug Test 7. Revision to indentation t

    5、est for Part IV coated tanks 8. Deletion of terms Type I Tank and Type II Tank 9. Clarication of requirements for FRP matrix (resin Flammable and Combustible Liquids Code, NFPA 30; Code for Motor Fuel Dispensing Facilities and Repair Garages, NFPA 30A; International Fire Code, published by the Inter

    6、national Code Council. 1.3 revised December 19, 2014 1.4 These tanks are completely fabricated, inspected and tested for protection system defects and/or tank leakage before shipment from the factory as completely assembled vessels and are intended for burial in accordance with the manufacturers ins

    7、tructions. 1.4 revised December 19, 2014 2 General 2.1 Components 2.1.1 Except as indicated in 2.1.2, a component of a product covered by this standard shall comply with the requirements for that component. 2.1.2 A component is not required to comply with a specic requirement that: a) Involves a fea

    8、ture or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. DECEMBER 19, 2014 UL 1746 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM U

    9、L 2.1.3 A component shall be used in accordance with its rating established for the intended conditions of use. 2.1.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certa

    10、in temperatures not exceeding specied limits, and shall be used only under those specic conditions. 2.2 Units of measurements 2.2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 2.3 Undated references 2.3.1 Any undated refere

    11、nce to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. 2.4 Terminology 2.4.1 In the following text, a requirement that applies only to a particular type of tank is so identied by a specic reference in

    12、 that requirement to the type or types of tank involved. Absence of such specic reference or use of the term “tank” indicates that the requirement applies to all underground storage tanks unless indicated otherwise. 3 Glossary 3.1 For the purpose of this standard the following denitions apply. 3.1 r

    13、evised December 19, 2014 3.1.1 ATMOSPHERIC TANK A storage tank that has been designed to operate at pressures of negative 0.5 psig to 1.0 (negative 3.4 kPa to 6.8 kPa) psig measured at the top of the tank. 3.1.1 added December 19, 2014 3.1.2 CATHODICALLY PROTECTED TANK A steel tank with a pre-engine

    14、ered, factory installed galvanic type cathodic protection system consisting of anodes, dielectric coatings, isolated devices and accessories applied to outer tank shell which provides external corrosion protection. Cathodically protected tank requirements are found in Part I. 3.1.2 added December 19

    15、, 2014 3.1.3 COATED TANK A steel tank with a polyurethane (PUR) layer directly bonded to the exterior of the tank which provides external corrosion protection. The polyurethane (PUR) layer does not provide an interstitial space. Coated tank requirements are found in Part IV. 3.1.3 added December 19,

    16、 2014 3.1.4 COMPOSITE TANK A steel tank with a ber reinforced plastic (FRP) layer or laminate directly bonded to the exterior of the tank which provides external corrosion protection. The FRP layer or laminate does not provide an interstitial space. Composite tank requirements are found in Part II.

    17、3.1.4 added December 19, 2014 DECEMBER 19, 2014 UL 1746 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3.1.5 HOLIDAY A small fault, crack, pin hole, or other defect in a non metallic dielectric coating, coating, covering or structural laye

    18、r, that results in a spark detection when tested with high voltage apparatus as dened in this standard. 3.1.5 added December 19, 2014 3.1.6 INTERSTITIAL SPACE (aka ANNULAR SPACE, INTERSTICE) A space between the walls of a multiple wall tank that is capable of communicating uid from a leak in an adja

    19、cent wall to a collection point for monitoring. 3.1.6 added December 19, 2014 3.1.7 JACKETED TANK A steel tank in a ber reinforced plastic (FRP), high density polyethylene (HDPE), polyurea, or polyurethane (PUR) that forms an interstitial space, where the jacket provides secondary containment and ex

    20、ternal corrosion protection. Jacketed tank requirements are found in Part III. 3.1.7 added December 19, 2014 3.1.8 PRIMARY CONTAINMENT The ability of an enclosed design or construction to directly contact and contain a liquid while in normal use. 3.1.8 added December 19, 2014 3.1.9 PRIMARY TANK An i

    21、nner wall of a tank construction that provides containment of the product being stored. 3.1.9 added December 19, 2014 3.1.10 SECONDARY CONTAINMENT The ability of a design or construction to directly contact and contain a liquid to a minimum of 300 degrees only in abnormal use (from primary containme

    22、nt leakage or rupture). 3.1.10 added December 19, 2014 3.1.11 STORAGE TANK (TANK) A vessel having a liquid capacity that exceeds 60 gallons (230 L), is intended for xed installation, and is not used for processing. Reprinted with permission from NFPA 30, Flammable and Combustible Liquids Code, Copyr

    23、ight 2003, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject which is presented only by the standard in its entirety. 3.1.11 added December 19, 2014 3.1.12 UN

    24、DERGROUND TANK (aka UNDERGROUND STORAGE TANK or UST) A storage tank that is intended for installation at least 12 inches (304.8 mm) below grade and in direct contact with backll. 3.1.12 added December 19, 2014 3.2 deleted December 19, 2014. 3.3 deleted December 19, 2014. 3.4 deleted December 19, 2014. 3.5 deleted December 19, 2014. 3.6 deleted December 19, 2014. DECEMBER 19, 2014 UL 1746 8A


    注意事项

    本文(UL 1746-2007 UL Standard for Safety External Corrosion Protection Systems for Steel Underground Storage Tanks (Third Edition Reprint with Revisions Through and Including December 1_1.pdf)为本站会员(rimleave225)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开