欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    TIA-620A000-1995 Sectional Specification for Single- Mode Fiber Optic Branching Devices for Outside Plant Applications《室外平台应用的单模光纤分支设备的部分规范》.pdf

    • 资源ID:1060729       资源大小:703.12KB        全文页数:24页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    TIA-620A000-1995 Sectional Specification for Single- Mode Fiber Optic Branching Devices for Outside Plant Applications《室外平台应用的单模光纤分支设备的部分规范》.pdf

    1、 TIA-620A000 May 1995Sectional Specification for Single- Mode Fiber Optic Branching Devices for Outside Plant Applications TIA-620A000-1995 APPROVED: MAY 1, 1995 REAFFIRMED: JANUARY 23, 2002 REAFFIRMED: JANUARY 29, 2014 NOTICE TIA Engineering Standards and Publications are designed to serve the publ

    2、ic interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular need. The existence of such Standards

    3、 and Publications shall not in any respect preclude any member or non-member of TIA from manufacturing or selling products not conforming to such Standards and Publications. Neither shall the existence of such Standards and Publications preclude their voluntary use by Non-TIA members, either domesti

    4、cally or internationally. Standards and Publications are adopted by TIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standar

    5、d or Publication. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulato

    6、ry limitations before its use. (From Project No. 3-2084-RF2, formulated under the cognizance of the TIA TR-42 Telecommunications Cabling Systems, TR-42.13 Subcommittee on Passive Optical Devices and Fiber Optic Metrology). Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION Technology (b) there is

    7、no assurance that the Document will be approved by any Committee of TIA or any other body in its present or any other form; (c) the Document may be amended, modified or changed in the standards development or any editing process. The use or practice of contents of this Document may involve the use o

    8、f intellectual property rights (“IPR”), including pending or issued patents, or copyrights, owned by one or more parties. TIA makes no search or investigation for IPR. When IPR consisting of patents and published pending patent applications are claimed and called to TIAs attention, a statement from

    9、the holder thereof is requested, all in accordance with the Manual. TIA takes no position with reference to, and disclaims any obligation to investigate or inquire into, the scope or validity of any claims of IPR. TIA will neither be a party to discussions of any licensing terms or conditions, which

    10、 are instead left to the parties involved, nor will TIA opine or judge whether proposed licensing terms or conditions are reasonable or non-discriminatory. TIA does not warrant or represent that procedures or practices suggested or provided in the Manual have been complied with as respects the Docum

    11、ent or its contents. If the Document contains one or more Normative References to a document published by another organization (“other SSO”) engaged in the formulation, development or publication of standards (whether designated as a standard, specification, recommendation or otherwise), whether suc

    12、h reference consists of mandatory, alternate or optional elements (as defined in the TIA Engineering Manual, 4thedition) then (i) TIA disclaims any duty or obligation to search or investigate the records of any other SSO for IPR or letters of assurance relating to any such Normative Reference; (ii)

    13、TIAs policy of encouragement of voluntary disclosure (see Engineering Manual Section 6.5.1) of Essential Patent(s) and published pending patent applications shall apply; and (iii) Information as to claims of IPR in the records or publications of the other SSO shall not constitute identification to T

    14、IA of a claim of Essential Patent(s) or published pending patent applications. TIA does not enforce or monitor compliance with the contents of the Document. TIA does not certify, inspect, test or otherwise investigate products, designs or services or any claims of compliance with the contents of the

    15、 Document. ALL WARRANTIES, EXPRESS OR IMPLIED, ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION, ANY AND ALL WARRANTIES CONCERNING THE ACCURACY OF THE CONTENTS, ITS FITNESS OR APPROPRIATENESS FOR A PARTICULAR PURPOSE OR USE, ITS MERCHANTABILITY AND ITS NONINFRINGEMENT OF ANY THIRD PARTYS INTELLECTUAL PR

    16、OPERTY RIGHTS. TIA EXPRESSLY DISCLAIMS ANY AND ALL RESPONSIBILITIES FOR THE ACCURACY OF THE CONTENTS AND MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE CONTENTS COMPLIANCE WITH ANY APPLICABLE STATUTE, RULE OR REGULATION, OR THE SAFETY OR HEALTH EFFECTS OF THE CONTENTS OR ANY PRODUCT OR SERVICE

    17、 REFERRED TO IN THE DOCUMENT OR PRODUCED OR RENDERED TO COMPLY WITH THE CONTENTS. TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT OR INDIRECT, ARISING FROM OR RELATING TO ANY USE OF THE CONTENTS CONTAINED HEREIN, INCLUDING WITHOUT LIMITATION ANY AND ALL INDIRECT, SPECIAL, INCIDENTAL OR CONSE

    18、QUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS, LOSS OF PROFITS, LITIGATION, OR THE LIKE), WHETHER BASED UPON BREACH OF CONTRACT, BREACH OF WARRANTY, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE FOREGOING NEGATION OF D

    19、AMAGES IS A FUNDAMENTAL ELEMENT OF THE USE OF THE CONTENTS HEREOF, AND THESE CONTENTS WOULD NOT BE PUBLISHED BY TIA WITHOUT SUCH LIMITATIONS. TINEIA-620A000 Sectional specification for single-mode fiber optic branching devices for outside plant applications Contents Foreword i II . 1 2 3 3.1 3.2 3.3

    20、 3.4 3.5 4 4.1 4.2 4.3 4.4 5 5.1 5.2 5.3 6 6.1 6.2 6.3 Introduction 1 Normative references 1 Background information 2 Object 2 Information to be given in a Detail Specification . 2 Shipping package 3 Numbering system 3 Marking . 3 Required attributes. preferred values and characteristics . 3 Classif

    21、ication . 3 Optical attributes . 4 Mechanical attributes . 4 Envi ron mental attributes . 5 Quality assessment procedures . 5 Qualification approval 5 Quality conformance inspection (QCI) 6 Minimum list of attributes . 6 Test And Measurement Procedures . 1 0 Optical . 1 0 Mechanical 1 0 Environmenta

    22、l . 1 1 Annex A Quality Conformance Inspection Codes 1 2 I EIA TIA-620A000 95 = 3234600 0563093 208 TINEIA-620A000 (This page left blank.) II EIA TIA-620AO 95 3234b00 0563092 144 Sectional specification for single-mode fiber optic branching devices for outside plant applications Foreword (This forew

    23、ord is informative only and is not part of this Standard.) This specification comes from TIA Standards Proposal Number 2084, formulated under the cognizance of TIA FO-6.3, Subcommittee on Fiber Optic Interconnecting Devices. This Specification forms a part of a set of TINEIA standards that systemati

    24、cally specifies performance requirements for branching devices. This hierarchical specification system comprises four tiers: The Generic Specification, TINEIA-6200000, is the umbrella document for all branching device specifications. It delineates minimum requirements that are common to all branchin

    25、g device types, as well as providing a “shopping list“ of test requirements and test methods that may be applied to families of branching devices targeted toward various applications, and to specific groups of branching device designs; Sectional Specifications define requirements for branching devic

    26、e families, ordered by primary application. They set forth requirements applicable to all branching devices in the family. Sectional Specifications reference the Generic Specification, extracting requirements applicable to the branching device family. They may introduce other requirements that are n

    27、ot addressed in the Generic Specification. Values for most requirements are delegated specifically to the Detail Specifications; Blank Detail Specifications are prepared for a limited series of branching device subfamilies that fall within the family of the relevant Sectional Specification. They giv

    28、e specific directions for writing Detail Specifications and may introduce additional requirements that are not addressed in the hig her-order documents; Detail Specifications follow the applicable Blank Detail Specification and provide detailed requirements for specific applications. They also may i

    29、ntroduce additional requirements not addressed in the higher-order documents. Values for primary performance requirements are given in the Detail Specifications. Detail Specifications may be written by TIA Working Groups or by manufacturers. Some attributes may be delegated to the procurement docume

    30、nt. The procurement document references the applicable Detail Specification. For additional information on this system of Specifications, refer to EIA Engineering Publication EP-11 -A. . 111 - EIA TIA-bEOA000 95 = 3234600 05b3073 080 TINEIA-620A000 (This page left blank.) iv 1 Introduction TINEIA-62

    31、0A000 1.1 Intent This Specification was formulated for the purpose of providing a document setting forth engineering and use requirements as necessary for purchase of single-mode passive branching devices for outside plant applications. Use of this document is intended to eliminate misunderstandings

    32、 or confusion between the supplier and user with respect to product performance requirements and test procedures. All Detail Specifications shall be derived from this Sectional Specification, all associated Blank Detail Specifications, the Generic Specification TINEIA- 6200000, and EIARIA-455-A. The

    33、se documents follow the specification structure used in the U.S. National Electronic Components Quality Assessment System (NECQ). For further details, see the Foreword. 1.2 Scope This Specification applies to uniform (equal splitting ratio) single-mode passive branching devices that are designed for

    34、 outside plant applications. 2 Normative references The latest published revisions, addendums, and notices for the issue of the following documents in effect on the date of use of this Specification in invitation for bids or requests for proposals, form part of this Specification to the extent speci

    35、fied herein: Ge n er i c S peci f i cat i o n T I A/E I A- 6 20000 O, Generic Specification for Passive Branching Devices EIA/TIA-455-A Standard Test Procedures for Fiber Optic Fibers, Cables, Transducers, Sensors, Connecting and Terminating Devices, and Other Fiber Optic Components 1 EIA TIA-620A00

    36、0 75 3234600 05b3095 953 W 3 Background information 3.1 Object The object of this Specification is to define requirements for passive branching devices and to assist those who prepare Detail Specifications based on this document. This object is carried out, in part, by prescribing required attribute

    37、s and their preferred values or characteristics, and in selecting from the Generic Specification the appropriate quality assessment procedures, tests, and measurement methods. Clause 4 specifies the attributes that must be specified in a derived Detail Specification, along with preferred values and

    38、characteristics. Clause 5 describes the Quality Assessment procedures and includes qualification approval and Quality Conformance Inspection (QCI) requirements. Clause 6 outlines the recommended tests and measurements. This Specification also indicates which test options and performance requirements

    39、 may be left to the Detail Specification writer. 3.2 Information to be given in a Detail Specification Each Detail Specification shall be derived from a Blank Detail Specification. Required attributes and preferred values are given in clause 4 of this Sectional Specification. Additional attributes o

    40、r preferred values may be specified. In addition, the following information shall be given in each Detail Specification: 3.2.1 Classification and type requirements Product classification and contruction information, along with a description of the application, shall be in the Detail Specification. 3

    41、.2.2 Required performance attributes For each required attribute, specify the following: a) Attribute name b) Test procedure(s) and information required by the procedures c) One of the following: - Limit bound(s) - Nominal value(s) and tolerance 2 EIA TIA-620A000 95 3234600 0.563096 9T W TIN EI A-62

    42、0A000 d) Minimum sample size for qualification and periodic requalification e) Minimum frequency for periodic requalification f) Additional QCI method(s) and associated required information Normative annexes may be used to record classes of specified information so that the body of the Detail Specif

    43、ication can remain tabular. Information required in the Detail Specification by the test procedures is an example. A tabular form for the body of the Detail Specification may include columnar headings for annex references. 3.2.3 Additional attributes The Blank Detail or Detail Specifications may con

    44、tain additional attributes. All information required in 3.2.2 shall be specified for these additions. 3.3 Marking Marking is a requirement for all branching devices specified with this document. 3.4 Shipping package Performance specifications of the shipping package shall be specified in the Detail

    45、Specif icati o n . 3.5 Numbering system The numbering system shall conform to the provisions given in 3.6.1 of the Generic Specification. 4 Required attributes, preferred values, and characteristics The minimum list of attributes that shall be specified in the Detail Specification are given in this

    46、section. Preferred values and characteristics may also be given. Whenever the word “preferred,“ or “typically,“ appears below, it shall be considered to be synonymous with “recommended.“ The attributes specified in Detail Specifications shall include the following 4.1 Classification Describe the cla

    47、ssification according to 2.3 of the Generic Specification. 3 _ EIA TIA-b20A000 95 3234600 0563097 726 4.2 Optical attributes 4.2.1 Optical bandpass Specify a nominal value, typically 820 nm, 1310 nm, or 1550 nm, and tolerance in the Detail Specification. Multiple bandpass ranges may be specified if

    48、required. 4.2.2 Insertion loss Specify a minimum and maximum value over the bandpass in the Detail Specification. 4.2.3 Directivity Specify a minimum value over the bandpass in the Detail Specification. 4.2.4 Return loss Specify a minimum value over the bandpass in the Detail Specification. 4.2.5 Po

    49、larization dependence Specify a maximum value over the bandpass in the Detail Specification. 4.2.6 Other optical attributes There are no preferred values for other optical attributes. 4.3 Mechanical attributes 4.3.1 Impact Specify the number of cycles, the height, and the acceptance criteria in the Detail Specification. 4.3.2 Cablelfiber retention Specify the tensile force and acceptance criteria in the Detail Specification. 4.3.3 Vibration Specify the acceptance criteria in the Detail Specification. 4.3.4 Other mechanical attributes The


    注意事项

    本文(TIA-620A000-1995 Sectional Specification for Single- Mode Fiber Optic Branching Devices for Outside Plant Applications《室外平台应用的单模光纤分支设备的部分规范》.pdf)为本站会员(tireattitude366)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开