欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    SANS 62226-1-2006 Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field indu.pdf

    • 资源ID:1031716       资源大小:743.94KB        全文页数:18页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    SANS 62226-1-2006 Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field indu.pdf

    1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA

    2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any

    3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 0-626-18914-4 SANS 62226-1:2006Edition 1 IEC 62226-1:2004Edition 1SOUTH AFRICAN NATIONAL STANDARD Exposure to electric or magnetic fields in the low

    4、 and intermediate frequency range Methods for calculating the current density and internal electric field induced in the human body Part 1: General This national standard is the identical implementation of IEC 62226-1:2004 and is adopted with the permission of the International Electrotechnical Comm

    5、ission. Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pretoria 0001 tel: 012 428 7911 fax: 012 344 1568 international code + 27 12 www.stansa.co.za Standards South Africa SANS 62226-1:2006 Edition 1 IEC 62226-1:2004 Edition 1 Table of changes Change No. Date Scope

    6、 National foreword This South African standard was approved by National Committee StanSA TC 73, Electromagnetic compatibility, in accordance with procedures of Standards South Africa, in compliance with annex 3 of the WTO/TBT agreement. This part of SANS 62226 was published in December 2006. NORME I

    7、NTERNATIONALECEIIECINTERNATIONAL STANDARD 62226-1Premire ditionFirst edition2004-11Exposition aux champs lectriques ou magntiques basse et moyenne frquence Mthodes de calcul des densits de courant induit et des champs lectriques induits dans le corps humain Partie 1: Gnralits Exposure to electric or

    8、 magnetic fields in the low and intermediate frequency range Methods for calculating the current density and internal electric field induced in the human body Part 1: General Pour prix, voir catalogue en vigueur For price, see current catalogue IEC 2004 Droits de reproduction rservs Copyright - all

    9、rights reserved Aucune partie de cette publication ne peut tre reproduite ni utilise sous quelque forme que ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie et les microfilms, sans laccord crit de lditeur. No part of this publication may be reproduced or utilized in any f

    10、orm or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20, SwitzerlandTelephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail:

    11、inmailiec.ch Web: www.iec.ch CODE PRIX PRICE CODE N Commission Electrotechnique InternationaleInternational Electrotechnical Commission SANS 62226-1:2006This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .62226-1 IEC:2004 3 CONTENTS FOREWORD.5 IN

    12、TRODUCTION.9 1 Scope.11 2 General data on electromagnetic fields and human exposure .11 2.1 General .11 2.2 Electric field 13 2.3 Magnetic field13 3 Terms and definitions, symbols and abbreviations 15 3.1 Terms and definitions 15 3.2 Physical quantities and units .21 3.3 Physical constants 23 4 Gene

    13、ral procedure for assessing compliance with safety limits.23 Bibliography25 Figure 1 Overview of different methods for assessing compliance with exposure limits .23 SANS 62226-1:2006This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .62226-1 IEC:

    14、2004 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ EXPOSURE TO ELECTRIC OR MAGNETIC FIELDS IN THE LOW AND INTERMEDIATE FREQUENCY RANGE METHODS FOR CALCULATING THE CURRENT DENSITY AND INTERNAL ELECTRIC FIELD INDUCED IN THE HUMAN BODY Part 1: General FOREWORD 1) The International Electrotechnical Comm

    15、ission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and

    16、in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee

    17、interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordan

    18、ce with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all intere

    19、sted IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsib

    20、le for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence be

    21、tween any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All u

    22、sers should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or o

    23、ther damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication

    24、. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such pat

    25、ent rights. International Standard IEC 62226 has been prepared by IEC technical committee 106: Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure. The text of this standard is based on the following documents: FDIS Report on voting 106/78/FDIS

    26、106/82/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. SANS 62226-1:2006This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .62226-1 IEC:2004 7 This publicatio

    27、n has been drafted in accordance with the ISO/IEC Directives, Part 2. This International Standard constitutes Part 1 of the IEC 62226 series, which will regroup several international standards and technical reports within the framework of the calculation of induced current densities and internal ele

    28、ctric fields, and will be published under the general title Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field induced in the human body. This series is planned to be published according to the

    29、 following structure: Part 1: General Part 2: Exposure to magnetic fields Part 2-1 : 2D models Part 2-2 : 3D models Part 2-3 : Guidelines for practical use of coupling factors Part 3: Exposure to electric fields Part 3-1: Analytical and 2D numerical models Part 3-2: 3D numerical models Part 4: Elect

    30、rical parameters of human living tissues (Technical Report) The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this dat

    31、e, the publication will be reconfirmed; withdrawn; replaced by a revised edition, or amended. SANS 62226-1:2006This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .62226-1 IEC:2004 9 INTRODUCTION Public interest concerning human exposure to electr

    32、ic and magnetic fields has led international and national organisations to propose limits based on recognised adverse effects. This standard applies to the frequency range for which the exposure limits are based on the induction of voltages or currents in human body, when exposed to electric and mag

    33、netic fields. This frequency range covers the low and intermediate frequencies, up to 100 kHz. Some methods described in this standard can be used at higher frequencies under specific conditions. The exposure limits based on biological and medical experimentation about these fundamental induction ph

    34、enomena are usually called “basic restrictions”. They include safety factors. The induced electrical quantities are not directly measurable, so simplified derived limits are also proposed. These limits, called “reference levels”, are given in terms of external electric and magnetic fields. They are

    35、based on very simple models of coupling between external fields and the body. These derived limits are conservative. Sophisticated models for calculating induced currents in the body have been used and are the subject of a number of scientific publications. These use numerical 3D electromagnetic fie

    36、ld computation codes and detailed models of the internal structure with specific electrical characteristics of each tissue within the body. However such models are still developing; the electrical conductivity data available at present has considerable shortcomings; and the spatial resolution of mod

    37、els is still advancing. Such models are therefore still considered to be in the field of scientific research and at present it is not considered that the results obtained from such models should be fixed indefinitely within standards. However it is recognised that such models can and do make a usefu

    38、l contribution to the standardisation process, especially for product standards in which particular cases of exposure are considered. When results from such models are used in standards, the results should be reviewed from time to time to ensure they continue to reflect the current status of the sci

    39、ence. SANS 62226-1:2006This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .62226-1 IEC:2004 11 EXPOSURE TO ELECTRIC OR MAGNETIC FIELDS IN THE LOW AND INTERMEDIATE FREQUENCY RANGE METHODS FOR CALCULATING THE CURRENT DENSITY AND INTERNAL ELECTRIC F

    40、IELD INDUCED IN THE HUMAN BODY Part 1: General 1 Scope This part of IEC 62226 provides means for demonstrating compliance with the basic restrictions on human exposure to low and intermediate frequency electric and magnetic fields specified in exposure standards or guidelines such as those produced

    41、by IEEE and ICNIRP. The object of IEC 62226 is to propose a more realistic approach to the modelling of the human exposure to low frequency electric and magnetic fields, using a set of models of growing complexity for the field emission source, or the human body or both; to propose standardised valu

    42、es for the electrical parameters of organs in human body: electrical conductivity and permittivity and their variation with the frequency. The present basic standard does not aim at replacing the definitions and procedures specified in exposure standards or guidelines, such as those produced by IEEE

    43、 or ICNIRP, but aims at providing additional procedures with a view to allowing compliance assessment with these documents. The present basic standard provides means for demonstrating compliance with the basic restrictions without having to go to the sophisticated models. Nevertheless, when the expo

    44、sure conditions are well characterized (such as in product standards, for example) and when results from such models are available, they can be used for demonstrating compliance with EMF standards or guidelines. NOTE 1 Examples of use of such sophisticated models can be found in the IEC Trend Techno

    45、logy Assessment 21. NOTE 2 References to the scientific literature are given in the bibliography. 2 General data on electromagnetic fields and human exposure 2.1 General The total field emitted by any electrical device when operating is composed of the electric field and the magnetic field and is ca

    46、lled the electromagnetic field. It is characterised by its frequency f or its wavelength , which is the ratio of the velocity of light in vacuum (c), divided by its frequency: = c/f. 1Figures in square brackets refer to the Bibliography SANS 62226-1:2006This s tandard may only be used and printed by

    47、 approved subscription and freemailing clients of the SABS .62226-1 IEC:2004 13 Where the wavelength is large compared with the distance of the individual from the equipment, and the size of the individual, the exposure to the fields is defined as “near field exposure“. Under these conditions, elect

    48、ric and magnetic fields are independent and can be studied separately. In practice this is valid for the range of frequencies covered by this standard. 2.2 Electric field Electric fields cause displacement of electric charges in conductive objects (including living bodies) and, because these fields

    49、are alternating, the electric charges move to and from. The result is an “induced” alternating current, and related induced electric field, inside the conductive object. It is important to note that, for an object of uniform conductivity, to a very large degree, this current is independent of whether the object is a good or a poor conductor of electricity. By contrast, the associated induced electric field strongly depends on


    注意事项

    本文(SANS 62226-1-2006 Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field indu.pdf)为本站会员(ideacase155)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开