欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    SANS 61442-2006 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7 2 kV) up to 30 kV (Um = 36 kV)《额定电压为6 kV(Um = 7 2 kV)到30 kV (Um = 36 kV) 的电源电缆附件.pdf

    • 资源ID:1031607       资源大小:850.15KB        全文页数:34页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    SANS 61442-2006 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7 2 kV) up to 30 kV (Um = 36 kV)《额定电压为6 kV(Um = 7 2 kV)到30 kV (Um = 36 kV) 的电源电缆附件.pdf

    1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA

    2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any

    3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 0-626-17958-0 SANS 61442:2006Edition 2IEC 61442:2005Edition 2SOUTH AFRICAN NATIONAL STANDARD Test methods for accessories for power cables with rate

    4、d voltages from 6 kV (Um= 7,2 kV) up to 30 kV (Um= 36 kV) This national standard is the identical implementation of IEC 61442:2005 and is adopted with the permission of the International Electrotechnical Commission. Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pr

    5、etoria 0001 tel: 012 428 7911 fax: 012 344 1568 international code + 27 12 www.stansa.co.za Standards South Africa SANS 61442:2006 Edition 2 IEC 61442:2005 Edition 2 Table of changes Change No. Date Scope National foreword This South African standard was approved by National Committee StanSA TC 66,

    6、Electric cables, in accordance with procedures of Standards South Africa, in compliance with annex 3 of the WTO/TBT agreement. This SANS edition cancels and replaces the first SABS edition (SABS IEC 61442:1997). NORME INTERNATIONALECEIIECINTERNATIONAL STANDARD 61442Deuxime ditionSecond edition2005-0

    7、3Mthodes dessais des accessoires de cbles dnergie de tensions assignes de 6 kV (Um = 7,2 kV) 30 kV (Um = 36 kV) Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) Pour prix, voir catalogue en vigueur For price, see current catalogue IEC

    8、 2005 Droits de reproduction rservs Copyright - all rights reserved Aucune partie de cette publication ne peut tre reproduite ni utilise sous quelque forme que ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie et les microfilms, sans laccord crit de lditeur. No part of thi

    9、s publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20, SwitzerlandTelephone:

    10、 +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmailiec.ch Web: www.iec.ch CODE PRIX PRICE CODE V Commission Electrotechnique InternationaleInternational Electrotechnical Commission 61442 IEC:2005 3 CONTENTS FOREWORD 7 1 Scope 11 2 Normative references .11 3 Test installations and conditions.1

    11、3 4 AC voltage tests.13 4.1 Dry test for all accessories 13 4.2 Wet test for outdoor terminations .13 4.3 Test in water for stop ends 15 5 DC voltage tests.15 5.1 Installation 15 5.2 Method15 6 Impulse voltage tests15 6.1 Installation 15 6.2 Method15 6.3 Test at elevated temperature .15 7 Partial di

    12、scharge test17 7.1 Method17 7.2 Test at elevated temperature .17 8 Tests at elevated temperature 17 8.1 Installation and connection 17 8.2 Measurement of temperature .17 9 Heating cycles voltage test.25 9.1 Installation 25 9.2 Test in air25 9.3 Test in water .25 9.4 Immersion test for outdoor termin

    13、ations .27 10 Thermal short-circuit test (screen) 27 10.1 Installation 27 10.2 Method27 11 Thermal short-circuit test (conductor) .29 11.1 Installation 29 11.2 Method29 12 Dynamic short-circuit test .31 12.1 Installation 31 12.2 Method31 13 Humidity and salt fog tests31 13.1 Apparatus .31 13.2 Insta

    14、llation 33 13.3 Method33 14 Impact test at ambient temperature.33 15 Screen resistance measurement.37 15.1 Installation 37 15.2 Method37 61442 IEC:2005 5 16 Screen leakage current measurement.37 16.1 Installation 37 16.2 Method37 17 Screen fault current initiation test .39 17.1 Installation 39 17.2

    15、Method41 18 Operating force test43 18.1 Installation 43 18.2 Method43 19 Operating eye test43 19.1 Installation 43 19.2 Method43 20 Capacitive test point performance.45 20.1 Installation 45 20.2 Test method 45 Annex A (informative) Determination of the cable conductor temperature47 Annex B (informat

    16、ive) Details of the test chamber and spray . equipment for humidity and salt fog tests .57 Bibliography .61 Figure 1 Terminations tested in air.19 Figure 2 Joints tested in air19 Figure 3 Separable connectors tested in air .21 Figure 4 Joints tested under water .21 Figure 5 Separable connectors test

    17、ed under water.23 Figure 6 Outdoor terminations tested under water 23 Figure 7 Heating cycle .25 Figure 8 Typical impact test apparatus for joints.35 Figure 9 Test arrangement for the screen leakage current measurement 39 Figure 10 Test arrangement for screen fault current initiation test.41 Figure

    18、A.1 Reference cable49 Figure A.2 Arrangement of the thermocouples49 Figure A.3 Current/temperatures curves.53 61442 IEC:2005 7 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 kV (Um = 7,2 kV) UP TO 30 kV (Um = 36 kV) FOREWORD 1) Th

    19、e International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical an

    20、d electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical co

    21、mmittees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization

    22、for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committ

    23、ee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is a

    24、ccurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and reg

    25、ional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conform

    26、ity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any

    27、personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative

    28、 references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsibl

    29、e for identifying any or all such patent rights. International Standard IEC 61442 has been prepared by IEC technical committee 20: Electric cables. This second edition of IEC 61442 cancels and replaces the first edition of IEC 61442, published in 1997, and constitutes a technical revision. Significa

    30、nt technical changes with respect to the previous edition are as follows: a) a test in water has been added for stop ends; b) the heating cycles voltage test has been revised to clarify testing in air and water; c) the testing conditions for the short-circuit tests have been redefined; d) additional

    31、 information has been provided for testing separable connectors with a metallic housing; 61442 IEC:2005 9 e) tests not required by IEC, i.e. an immersion test for outdoor terminations and an impact test, have been included in order to have a common test method document with CENELEC under the IEC/CLC

    32、 Dresden agreement. The text of this standard is based on the following documents: FDIS Report on voting 20/748/FDIS 20/762/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted in acc

    33、ordance with the ISO/IEC Directives, Part 2. The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publicat

    34、ion will be reconfirmed; withdrawn; replaced by a revised edition, or amended. 61442 IEC:2005 11 TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 kV (Um = 7,2 kV) UP TO 30 kV (Um = 36 kV) 1 Scope This International Standard specifies the test methods to be used for type testi

    35、ng accessories for power cables with rated voltage from 3,6/6 (7,2) kV up to 18/30 (36) kV. Test methods are specified for accessories for extruded and paper insulated cables according to IEC 60502-2 and IEC 60055-1 respectively. 2 Normative references The following referenced documents are indispen

    36、sable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including amendments) applies. IEC 60055-1: Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or

    37、 aluminium conductors and excluding gas-pressure and oil-filled cables) Part 1: Tests on cables and their accessories IEC 60060-1:1989, High-voltage test techniques Part 1: General definitions and test requirements IEC 60230:1966, Impulse tests on cables and their accessories IEC 60270:2000, High-vo

    38、ltage test techniques Partial discharge measurements IEC 60502-2:2005, Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) IEC 60811-1-2:1985

    39、, Common test methods for insulating and sheathing materials of electric and optical cables Part 1: Methods for general application Section Two: Thermal ageing methods IEC 60885-3:1988, Electrical test methods for electric cables Part 3: Test methods for partial discharge measurements on lengths of

    40、extruded power cables IEC 60986:2000, Short-circuit temperature limits of electric cables with rated voltages from 6 kV (Um= 7,2 kV) up to 30 kV (Um= 36 kV) IEC 61238-1:2003, Compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um= 36 kV) Part 1: Test methods and re

    41、quirements 61442 IEC:2005 13 3 Test installations and conditions 3.1 The test methods described in this standard are intended to be used for type tests. 3.2 Test arrangements and the number of test samples are given in the relevant standard. 3.3 The test conditions are specified in Clauses 4 to 20 o

    42、f this standard. When they are not, they shall be as specified in the relevant standards. 3.4 Unless otherwise stated, the testing parameters and the requirements are given in the relevant standard. 3.5 For transition joints (either extruded insulation to extruded insulation or extruded insulation t

    43、o paper insulation), the testing parameters (voltage and conductor temperature) are those for the lower rated cable. 3.6 The tests shall be started not less than 24 h after the installation of the accessories on the cable test loops, unless otherwise specified by the manufacturer. The time interval

    44、shall be recorded in the test report. 3.7 Cable screens, and armour if any, shall be bonded and earthed at one end only to prevent circulating currents. 3.8 All parts of an accessory which are normally earthed shall be connected to the cable screen. Any supporting metalwork shall also be earthed. 3.

    45、9 Ambient temperature shall be (20 15) C. 3.10 Tap water shall be used for all tests in water. 4 AC voltage tests 4.1 Dry test for all accessories 4.1.1 Installation The set(s) of accessories shall be erected with all associated metalwork and fittings. The accessories shall be clean and dry before a

    46、pplying the test voltage. 4.1.2 Method Unless otherwise specified, the test shall be made at ambient temperature, and the procedure for voltage application shall be as specified in Section 5 of IEC 60060-1. 4.2 Wet test for outdoor terminations 4.2.1 Installation The terminations shall be erected in

    47、 a vertical position, unless they are to be specifically installed in another orientation, with the relative spacing as under service conditions and according to manufacturers instructions. 61442 IEC:2005 15 4.2.2 Method Unless otherwise specified, the wet test method is as described in 9.1 of IEC 6

    48、0060-1, and shall be carried out at ambient temperature. 4.3 Test in water for stop ends 4.3.1 Installation The stop ends shall be installed in a water tank of such dimensions as to have a height of water of 1,0002,00 +m over their top surface, unless otherwise specified. The water shall be at ambie

    49、nt temperature. 4.3.2 Method Unless otherwise specified, the procedure for voltage application shall be as specified in IEC 60060-1. 5 DC voltage tests 5.1 Installation The set(s) of accessories shall be erected with all associated metalwork and fittings. The accessories shall be clean and dry before applying the test voltage. 5.2 Method A voltage of negative polarity shall be applied to the cable conductor. The tes


    注意事项

    本文(SANS 61442-2006 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7 2 kV) up to 30 kV (Um = 36 kV)《额定电压为6 kV(Um = 7 2 kV)到30 kV (Um = 36 kV) 的电源电缆附件.pdf)为本站会员(explodesoak291)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开