欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    SANS 5725-1-2009 Accuracy (trueness and precision) of measurement methods and results Part 1 General principles and definitions《测量方法及结果的精度(真实度及精确度) 第1部分 总则及定义》.pdf

    • 资源ID:1031046       资源大小:4.28MB        全文页数:30页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    SANS 5725-1-2009 Accuracy (trueness and precision) of measurement methods and results Part 1 General principles and definitions《测量方法及结果的精度(真实度及精确度) 第1部分 总则及定义》.pdf

    1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA

    2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any

    3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-22659-6 SANS 5725-1:2009Edition 1 and ISO tech. corr.1ISO 5725-1:1994Edition 1 and tech. corr.1SOUTH AFRICAN NATIONAL STANDARD Accuracy (t

    4、rueness and precision) of measurement methods and results Part 1: General principles and definitions This national standard is the identical implementation of ISO 5725-1:1994 and ISO technical corrigendum 1, and is adopted with the permission of the International Organization for Standardization. Pu

    5、blished by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS SANS 5725-1:2009 Edition 1 and ISO tech. corr. 1 ISO 5725-1:1994 Edition 1 and tech. corr. 1 Table of changes Change No. Date Scope ISO tech. co

    6、rr. 1 1998 Corrected to replace table 2 with a new table. National foreword This South African standard was approved by National Committee SABS TC 169, Applications of statistical methods, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreeme

    7、nt. This SANS document was published in August 2009. ICS 03.120.30; 17.020 Ref. No. ISO 5725-1:1994/Cor.1:1998(E)Descriptors: measurement, tests, test results, accuracy, reproducibility, statistical analysis, definitions, generalities. ISO 1998Printed in SwitzerlandAINTERNATIONAL STANDARD ISO 5725-1

    8、:1994TECHNICAL CORRIGENDUM 1Published 1998-02-15INTERNATIONAL ORGANIZATION FOR STANDARDIZATION ORGANISATION INTERNATIONALE DE NORMALISATIONAccuracy (trueness and precision) of measurementmethods and results Part 1:General principles and definitionsTECHNICAL CORRIGENDUM 1Exactitude (justesse et fidli

    9、t) des rsultats et mthodes de mesure Part 1: Principes gnraux et dfinitionsRECTIFICATIF TECHNIQUE 1Technical Corrigendum 1 to International Standard ISO 5725-1:1994 was prepared by Technical CommitteeISO/TC 69, Applications of statistical methods, Subcommittee SC 6, Measurement methods and results.P

    10、age 10, table 2Replace table 2 with the following table (taken from table 1 of ISO 5725-4:1994):SANS 5725-1:2009This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .ISO 5725-1:1994/Cor.1:1998(E)ISO2Table 2 Values of A, the uncertainty of an estima

    11、te of the bias of the measurement methodNo. oflabora-toriesValue of Ag = 1 g = 2 g = 5pn = 2 n = 3 n = 4 n = 2 n = 3 n = 4 n = 2 n = 3 n = 45 0,62 0,51 0,44 0,82 0,80 0,79 0,87 0,86 0,8610 0,44 0,36 0,31 0,58 0,57 0,56 0,61 0,61 0,6115 0,36 0,29 0,25 0,47 0,46 0,46 0,50 0,50 0,5020 0,31 0,25 0,22 0,

    12、41 0,40 0,40 0,43 0,43 0,4325 0,28 0,23 0,20 0,37 0,36 0,35 0,39 0,39 0,3930 0,25 0,21 0,18 0,33 0,33 0,32 0,35 0,35 0,3535 0,23 0,19 0,17 0,31 0,30 0,30 0,33 0,33 0,3340 0,22 0,18 0,15 0,29 0,28 0,28 0,31 0,31 0,31SANS 5725-1:2009This s tandard may only be used and printed by approved subscription

    13、and freemailing clients of the SABS .INTERNATIONAL STANDARD IS0 5725-l First edition 1994-I 2-15 Accuracy (trueness and precision) of measurement methods and results - Part 1: General principles and definitions Exactitude (justesse et fidblit6) des r the factors that influence the outcome of a measu

    14、rement cannot all be completely controlled. In the practical interpretation of measurement data, this vari- ability has to be taken into account. For instance, the difference between a test result and some specified value may be within the scope of un- avoidable random errors, in which case a real d

    15、eviation from such a specified value has not been established. Similarly, comparing test results from two batches of material will not indicate a fundamental quality dif- ference if the difference between them can be attributed to the inherent variation in the measurement procedure. 0.3 Many differe

    16、nt factors (apart from variations between supposedly identical specimens) may contribute to the variability of results from a measurement method, including: a) the operator; b) c) d e) the equipment used; the calibration of the equipment; the environment (temperature, humidity, air pollution, etc.);

    17、 the time elapsed between measurements. The variability between measurements performed by different operators and/or with different equipment will usually be greater than the variability between measurements carried out within a short interval of time by a single operator using the same equipment. 0

    18、.4 The general term for variability between repeated measurements is precision. Two conditions of precision, termed repeatability and reproduc- ibility conditions, have been found necessary and, for many practical cases, useful for describing the variability of a measurement method. Un- der repeatab

    19、ility conditions, factors a) to e) listed above are considered SANS 5725-1:2009This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .IS0 5725=1:1994(E constants and do no ibility conditions the contribute to the variability, while under reproduc- v

    20、ary and do contribute to the variability of the test results. Thus repeatability and reproducibility are the two extremes of precision, the first describing the minimum and the second the maximum variability in results. Other intermediate conditions between these two extreme conditions of precision

    21、are also conceivable, when one or more of factors a) to e) are allowed to vary, and are used in certain specified circumstances. Precision is normally expressed in terms of standard devi- ations. 0 IS0 0.5 The “trueness” of a measurement method is of interest when it is possible to conceive of a tru

    22、e value for the property being measured. Al- though, for some measurement methods, the true value cannot be known exactly, it may be possible to have an accepted reference value for the property being measured; for example, if suitable reference materials are available, or if the accepted reference

    23、value can be established by refer- ence to another measurement method or by preparation of a known sample. The trueness of the measurement method can be investigated by comparing the accepted reference value with the level of the results given by the measurement method. Trueness is normally expresse

    24、d in terms of bias. Bias can arise, for example, in chemical analysis if the measurement method fails to extract all of an element, or if the presence of one element interferes with the determination of another. 0.6 The general term accuracy is used in IS0 5725 to refer to both trueness and precisio

    25、n. The term accuracy was at one time used to cover only the one component now named trueness, but it became clear that to many persons it should imply the total displacement of a result from a reference value, due to random as well as systematic effects. The term bias has been in use for statistical

    26、 matters for a very long time, but because it caused certain philosophical objections among members of some professions (such as medical and legal practitioners), the positive aspect has been emphasized by the invention of the term trueness. vi SANS 5725-1:2009This s tandard may only be used and pri

    27、nted by approved subscription and freemailing clients of the SABS .INTERNATIONAL STANDARD Q ISO IS0 5725=1:1994(E) Accuracy (trueness and precision) of measurement methods and results - Part 1: General principles and definitions 1 Scope 1.1 The purpose of IS0 5725 is as follows: a) to outline the ge

    28、neral principles to be understood when assessing accuracy (trueness and precision) of measurement methods and results, and in ap- plications, and to establish practical estimations of the various measures by experiment (IS0 5725-I) I b) to provide a basic method for estimating the two extreme measur

    29、es of the precision of measure- ment methods by experiment (IS0 5725-2); c) to provide a procedure for obtaining intermediate measures of precision, giving the circumstances in which they apply and methods for estimating them (IS0 5725-3); d) to provide basic methods for the determination of the tru

    30、eness of a measurement method (IS0 5725-4); e) to provide some alternatives to the basic meth- ods, given in IS0 5725-2 and IS0 5725-4, for de- termining the precisior measurement methods fo cumstances (IS0 5725-5); and trueness of * use under certain cir- f) to present some practica I applications

    31、of these measures of trueness and precision (IS0 5725-6). I.2 This part of IS0 5725 is concerned exclusively with measurement methods which yield measure- ments on a continuous scale and give a single value as the test result, although this single value may be the outcome of a calculation from a set

    32、 of observa- tions. It defines values which describe, in quantitative terms, the ability of a measurement method to give a correct result (trueness) or to replicate a given result (precision). Thus there is an implication that exactly the same thing is being measured, in exactly the same way, and th

    33、at the measurement process is un- der control. This part of IS0 5725 may be applied to a very wide range of materials, including liquids, powders and solid objects, manufactured or naturally occurring, provided that due consideration is given to any heterogeneity of the material. 2 Normative referen

    34、ces The following standards contain provisions which, through reference in this text, constitute provisions of this part of IS0 5725. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this part of IS0 5725 are enc

    35、ouraged to investigate the possibility of applying the most recent editions of the standards indicated below. Members of IEC and IS0 maintain registers of currently valid International Standards. SANS 5725-1:2009This s tandard may only be used and printed by approved subscription and freemailing cli

    36、ents of the SABS .IS0 5725-l :I 994(E) 0 IS0 IS0 3534-l :I 993, Statistics - Vocabulary and sym- bols - Part I: Probability and general statistical terms. 3.5 accepted reference value: A value that serves as an agreed-upon reference for comparison, and which is derived as: IS0 5725-2: 1994, Accuracy

    37、 (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and re- producibility of a standard measurement method. a) a theoretical or e scientific principles; stablished value, on b) an assigned or certified value, based on exper- imen

    38、tal work of some national or international or- IS0 5725-3: 1994, Accuracy (trueness and precision) of measurement methods and results - Part 3: Intermediate measures of the precision of a standard measurement method. ganization; c) a consensus or certified value, based on collabor- ative experimenta

    39、l work under the auspices of a scientific or engineering group; IS0 5725-4: 1994, Accuracy (trueness and precision) of measurement methods and results - Part 4: Basic methods for the determination of the trueness of a standard measurement method. d) when a), b) and c) are not available, the expec- t

    40、ation of the (measurable) quantity, i.e. the mean of a specified population of measurements. ISO 3534-I 36 . a tes accuracy: The closeness of agreement between t result and the accepted reference value. 3 Definitions For the purposes of IS0 5725, the following defi- nitions apply. NOTE 2 The term ac

    41、curacy, when applied to a set of test results, involves a combination of random components and a common systematic error or bias component. Some definitions are taken from IS0 3534-l. ISO 3534-I The symbols used in IS0 5725 are given in annex A. 3.7 trueness: The closeness of agreement between the a

    42、verage value obtained from a large series of test results and an accepted reference value. 3.1 observed value: The value of a characteristic obtained as the result of a single observation. ISO 3534-I NOTES 3.2 test result: The value of a characteristic ob- tained by carrying out a specified test met

    43、hod. 3 The measure of trueness is usually expressed in terms of bias. 4 Trueness has been referred to as “accuracy of the mean”. This usage is not recommen ded. NOTE 1 The test method should specify that one or a number of individual observations be made, and their aver- age or another appropriate f

    44、unction (such as the median or the standard deviation) be reported as the test result. It may also require standard corrections to be applied, such as correction of gas volumes to standard temperature and pressure. Thus a test result can be a result calculated from several observed values. In the si

    45、mple case, the test result is the observed value itself. ISO 3534-I 3.8 bias: The difference between the expectation of the test results and an accepted reference value. NOTE 5 Bias is the total systematic error as contrasted to random error. There may be one or more systematic error components cont

    46、ributing to the bias. A larger systematic difference from the accepted reference value is reflected by a larger bias value. ISO 3534-I 3.3 level of the test in a precision experiment: The general average of the test results from all lab- oratories for one particular material or specimen tested. ISO

    47、3534-l-J 3.9 laboratory bias: The difference between the expectation of the test results from a particular lab- oratory and an accepted reference value. 34 . cell in a precision experiment: The test at a single level obtained by one laboratory. 2 SANS 5725-1:2009This s tandard may only be used and p

    48、rinted by approved subscription and freemailing clients of the SABS .Q IS0 IS0 5725=1:1994(E) 3.10 bias of the measurement method: The dif- ference between the expectation of test results ob- tained from all laboratories using that method and an accepted reference value. NOTE 6 One example of this i

    49、n operation would be where a method purporting to measure the sulfur content of a compound consistently fails to extract all the sulfur, giving a negative bias to the measurement method. The bias of the measurement method is measured by the dis- placement of the average of results from a large number of different laboratories all using the same method. The bias of a measurement method may be different at different levels. 3.11 laboratory component of bias: T between the laboratory bias and the measurement method. he dif bia


    注意事项

    本文(SANS 5725-1-2009 Accuracy (trueness and precision) of measurement methods and results Part 1 General principles and definitions《测量方法及结果的精度(真实度及精确度) 第1部分 总则及定义》.pdf)为本站会员(amazingpat195)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开