1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. SABS 0120 : Part 4 Section HE-1985 Cladding and sheeting PART 4 : TYPICAL SCHEDULES OF QUAEITXTIES SECTION HB CONTENTS Page Number SCHEDULE SECTION : CLA
4、DDING AND SHEETING . 1 February 1985 Approved by the COUNCIL OF THE SOUTH AFRICAN BUREAU OF STANDARDS 1 SABS 1200 1111 r CLADDING AND SHEETING SA85 0120 : Part 4 Section HB-1985 Cladding and fiheeting NGTE: See Clause 5 of Section 0. 1 tem No. Payment refers SABS 1200 HB 8.2.2 8.2.3 8.2.3 3.2.3 Shor
5、t Description SECTION : CLADDING AND SHEETING PRELIMINARY AND GENERAL SIDE AND ROOF CLADDING Supply, deliver to Site, erect and fix galvanized sheeting/ cladding, etc., in- cluding the supply of all necessary fasteners, etc., and cutting and notching: -. (See Drawinss H-4.1 to B-4.3 of Section H) Ap
6、proved troughed profile-cladding to sides and gables, 0.8 mm Approved troughed profile-sheeting to roofs, 0,8 mm To forming of 90 bullnosing to a 500 mm radius Flashings Ridge flashing 450-600 mm girth X 1 mm - 3 bends, baked enamel external finish Apron flashing 460-600 mm girth X l mm - 2 bends, b
7、aked enamel external finish Corner flashing 460-600 mm girth X 1 mm - 3 bends, baked enamel external finish Apex flashing 610-925 mm girth X 1 mm - 3 bends, baked enamel external finish Roof flashing 610-925 mm girth X 1 mm - 2 bends, baked enamel external finish Serrated closures to suit troughed p
8、rofile- cladding Side-wall flashing 460-600 mm girth X l mm - 2 bends, baked enamel external finish Counter flashing 250-300 mm girth X I mm - 1 bend, baked enamel external finish Ventilators Trouqhed profile-claddinq to ridse ventilators - - over Furnace Bay, curve 3 700 mm long sheets to radius of
9、 2 500 mm Troughed profile-cladding to roofs over Casting and Ladle Preparation Bays, curve ends of sheets under continuous ventilators to radius of 450 mm Approved colour coating of shceting 1 ainwater goods Troughed profile 200 mm wide X 150 m deep X 1 mm with beaded front lip and flanged back ljp
10、, including 7 outlets for 150 mm square downpipes and 6 stop-ends, baked enamel external finish Downpipes, 150 mm square X 1 mm, including 7 shoes and 31 brackets Polyethelene filler-pjeces under serrated closures facture to sides and gables, profile alvanized troughed profile-cladding ominal mass 2
11、.40 kg/m2 manu- to suit and Unit require1 m subcor riate it1 :ion H o ible. Amount r separal ct. selec from Secl ection HE, - con- n M SABS 0120 : Part 4 Section HB-1?85 Cladding and sheeting Payment refers 8.2.4 8.2.5 - Short Desc.ription Brought forward/. . . Painting - Painting of downpipes, shoe
12、s and brackets as specified in Subclause PSHB . of the project specification Tests a) As specified in Subclause 7.2.1 of SABS 1200 HB b) As specified in SubclLause 7.2.2 of SABS 1200 RB c) As fipecified in Sdbclause 7.3.1 of SABS 1200 BB d) As specified in Subclause 7.3.2 of SAES 1200 HB Unit No. NO. NO. No. NO. Quan- tity Rate