欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    SAE J 3053-2015 Heavy Duty Truck and Bus Electrical Circuit Performance Requirement for 12 24 Volt Electric Starter Motors.pdf

    • 资源ID:1027788       资源大小:449.99KB        全文页数:9页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    SAE J 3053-2015 Heavy Duty Truck and Bus Electrical Circuit Performance Requirement for 12 24 Volt Electric Starter Motors.pdf

    1、 _ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising ther

    2、efrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2015 SAE International All rights reserved. No part of this

    3、publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-49

    4、70 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J3053_201507 SURFACE VEHICLE RECOMMENDED PRACTICE J3053 JUL2015 Issued 2015-07 H

    5、eavy Duty Truck and Bus Electrical Circuit Performance Requirement for 12/24 Volt Electric Starter Motors RATIONALE This document is intended to give the industry a design standard to define the design of the electrical circuits used in conjunction with 12/24 volt electric starting motors. The docum

    6、ent will include all elements of the Electric Starter system main cranking and control circuits. 1. SCOPE The scope of this SAE Recommended Practice is to describe a design standard to define the maximum recommended voltage drop for starting motor main circuits as well as control system circuits for

    7、 12V through 24V starter systems. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this specification to the extent specified herein. Unless otherwise indicated, the latest issue of SAE publications shall apply. 2.1.1 SAE Publications Available from SAE International,

    8、 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or +1 724-776-4970 (outside USA), www.sae.org. SAEJ544 Electric Starting Motor Test Procedure 2.1.2 ISO Publications Available from International Organization for Standardization, ISO Central Secretariat, 1

    9、, ch. de la Voie-Creuse, CP 56, CH-1211 Geneva 20, Switzerland, Tel: +41 22 749 01 11, www.iso.org. ISO 8856 Amendment 1 Road Vehicles-Electrical Performance of Starter Motors-Test Methods and General Requirements SAE INTERNATIONAL J3053 Issued JUL2015 Page 2 of 9 3. DESCRIPTION The electrical crank

    10、ing system components in a heavy duty truck and bus include batteries, cabling, master disconnects, switches, control switches, relays, terminations and cranking motor. The starting system shall be designed in a fashion to provide the necessary engine RPM to start an engine under the most severe cli

    11、matic conditions for which the system is intended. This SAE Recommended Practice is focused on the starter motor electrical circuit and its corresponding circuit components (Shown in Figure 6 - Diagram of Crank Circuit Main Cables), but engine cranking has many other variables as shown in Figure 1 t

    12、hat will also influence engine cranking and starting performance. Engine manufactures may have minimum electrical system design guidelines defined to meet their engine starting requirements. These engine manufacture guidelines shall be considered by the truck and bus OE when designing the electrical

    13、 crank system. Truck and bus OEs may also incorporate a holistic electrical cranking system design. For example, by reviewing the minimum operating temperature, minimum required engine cranking speed, circuit components, starting aids, and recommended oil type, the OEM may choose to deviate from rec

    14、ommended circuit voltage drops: Battery Internal Resistance (Rbatt) may be reduced by applying a battery pack with a lower internal resistance, or by using ultracapacitors, or other alternative power sources (reference Fig. 6) A starting aid such as a block heater may allow the engine to crank at an

    15、 internal temperature that greatly exceeds cold climate ambient. Temperature aids such as an air preheater and low viscosity oil may be used. If a truck or bus OE electrical cranking system design deviates from the defined component VDs found in table shown in Figure 7, explicit service literature s

    16、hall be provided by the truck or bus OE defining the proper electrical crank system test procedure and a list of any specialized components such as specific battery chemistry. Figure 1 - Fishbone diagram SAE INTERNATIONAL J3053 Issued JUL2015 Page 3 of 9 4. COMPONENT STARTER MOTOR STRAIGHT DRIVE VS.

    17、 GEAR REDUCTION & STARTER EFFICIENCY Torque per Amp - The gear reduction starters have the advantage of producing more torque for a given amount of current (see Figure 2- Chart of Torque vs. Current). So in this regard, gear reduction is “more efficient“. Efficiency - True efficiency is defined as P

    18、ower Out /Power In. Gear reduction starters are more efficient than straight drive starters in the desired working range of the starter (see Figure 3 - Chart of Efficiency vs. Cranking speed) Speed vs. Voltage - For a given steady state current, speed is proportional to voltage. Both straight drive

    19、and gear reduction motors are affected nearly equally in this regard. As shown in Figure 4 Chart of Engine RPM vs. Starter Voltage, the slope is basically the same for straight drive and gear reduction. Figures 2 thru 4 were created from starter performance test data. The test method used to generat

    20、e this data conforms to SAE J544 and ISO 8856. (All data shown is relative to a 12 V Electrical System) Figure 2 - Chart of Starter Torque vs. Current 0204060801001201401601800 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000StarterTorque(Nm)Starter Current (amps)Torque per AmpGear Reduction

    21、 vs. Straight Drive StartersStraight DriveGear ReductionTypical 15L Engine at -18C with 15W40 OilSAE INTERNATIONAL J3053 Issued JUL2015 Page 4 of 9 Figure 3 - Chart of Starter Efficiency vs. Cranking RPM Figure 4 - Chart of Cranking Speed vs. Voltage 5. COLD CRANKING ENGINE RPM /VOLTAGE / CURRENT Th

    22、e bar charts in Figure 5 below are based on actual data from a cold crank test of a 13L engine with 15W40 oil at -18C fitted with a gear reduction starter motor. The crank data is based on 20 second continuous crank events. Fuel was disabled to prevent engine starting. Four different lead-acid batte

    23、ry packs were tested and all were conditioned to 70% state of charge. Since temperature and oil weight were held constant for all tests, the cranking torque demanded by the engine was also constant for each test. This cold crank data clearly demonstrates that: A. Cranking speed is proportional to vo

    24、ltage- voltage is relative to battery chemistry (battery internal resistance, Rbatt), but not necessarily a direct correlation to Cold Cranking Amps (CCA). As battery internal resistance increases, starter RPM will decrease as a result of lower available voltage at the starter. B. Current is proport

    25、ional to torque - required cranking torque was constant for each test, therefore current remained constant despite the different battery packs and resulting voltages during cranking. 010203040506070800 25 50 75 100 125 150 175 200StarterEfficiency(%)Cranking RPMStarter Efficiency vs. RPMStraight Dri

    26、veGR Manuf 1GR Manuf 2GR Manuf 30204060801001201401601802006 6.5 7 7.5 8 8.5 9 9.5 10 10.5 11CrankingRPMVoltageSpeed per VoltGear Reduction vs. Straight DriveStraight Drive RPMGear Reduction RPMSAE INTERNATIONAL J3053 Issued JUL2015 Page 5 of 9 Figure 5 - Charts of cold crank data SAE INTERNATIONAL

    27、J3053 Issued JUL2015 Page 6 of 9 6. STARTER ELECTRICAL CIRCUIT MAIN CRANKING CIRCUIT The main cranking circuit consists of the positive and negative cables, master disconnect switch and all circuit terminations (Figure 6 - Crank Circuit Diagram, Main Cables). Voltage drop measurement shall be perfor

    28、med by applying the highest reasonable current load to the circuit to minimize the signal to noise ratio. Measurements should be performed quickly to minimize changes in circuit resistance due to I X R heating affects. 120 amps is the minimum recommended load to be applied for measurement purposes.

    29、Figure 7 provides recommended values for VDROP/120AMPS, VDROP/500AMPS, as well as the equivalent resistance in Ohms. The starting motor circuits in motor vehicles shall be designed so that the difference between the voltage at the battery terminals and the starting motor terminals (including connect

    30、ions and disconnect switch) shall not exceed those values shown in Figure 7 - Table of Main Cranking Circuit Recommended Maximum Voltage Drop. The voltage drop values are defined with a normal circuit temperature of 20 nullC (68 nullF). Figure 6 - Crank circuit diagram, main cables Main Cranking Cir

    31、cuit Recommended Maximum Voltage Drop System Voltage Use Total Circuit Resistance V-drop/500 amps V-drop/120 amps Starter Output Range Max Engine Displacement 12 volt Light Duty 0.003- 0.004 - 0.36 -0.48V 0.9kw - 2.5kw 8 liter gas 3.5 liter diesel 12 volt Light / Medium Duty (LHDD) 0.002 1.0V 0.24V

    32、2.2kw - 3.3kw 6 liter 12 volt Medium Duty (MHDD) 0.0012 0.6V 0.14V 2.7kw 6.8kw 9 liter 24 volt Medium Duty (MHDD) 0.002 1.0V 0.24V 4.5kw -7.3kw 13 liter 12 volt Heavy Duty (HHDD) 0.001 0.5V 0.12V 6.8kw - 8.5kw 16 liter 24 volt Heavy Duty (HHDD) 0.002 1.0V 0.24V 7.0kw - 13kw 30 liter Figure 7 - Table

    33、 of main cranking circuit recommended maximum voltage drop all exceptions to this requirement shall be defined as described in section 3. SAE INTERNATIONAL J3053 Issued JUL2015 Page 7 of 9 6.1 Starter Electrical Circuit - Control Circuit Starter solenoid current draw varies widely based on the type

    34、of starter engagement system. Robust control circuit design is critical to the starter engagement reliability and solenoid life. Although still important, the control circuit design for starters equipped with IMS (Integrated Magnetic Switch) is less sensitive to voltage drop based on the relatively

    35、low current draw of the IMS coil ( 2 to 4 amps). For starters without IMS, the control circuit consists of the wiring from the battery power source to the magnetic switch, the magnetic switch contacts, and the wiring from the magnetic switch to the starter solenoid (see Figures 8 & 9 - Control Circu

    36、it Diagrams, with and without IMS). Vehicles with electronically managed starter controls shall consider protection for inductive voltage spikes resulting from de-energizing the starter solenoid. Likewise, the system design should ensure that (if) a control relay exist on the starter, that suppressi

    37、on is present on the coil of the relay which will ensure ample protection exist at the source where such inductive voltage spikes would be generated. Voltage drop measurement shall be performed by applying a current load suitable to the operating current level of the starter solenoid or IMS during t

    38、he initial engagement phase. Magnetic switch shall be energized to perform total circuit voltage drop measurement. (Disconnect circuit from starter motor prior to performing measurement.) Measurements should be performed quickly to minimize changes in circuit resistance due to I2X R heating affects.

    39、 Figure 10 describes several different engagement system types and provides recommended values for VDROP/100AMPS, as well as the equivalent resistance in . The starting motor control circuits in motor vehicles shall be designed so that the difference between the voltage at the battery terminals and

    40、the starting motor control circuit terminals (including connections) shall not exceed those values shown in Figure 10 - Table of Recommended Control Circuit Voltage Drops. The voltage drop values are defined with a normal circuit temperature of 20 C (68 F). Figure 8 - Control circuit diagram, withou

    41、t IMS (Integrated Magnetic Switch) SAE INTERNATIONAL J3053 Issued JUL2015 Page 8 of 9 Figure 9 - Control circuit diagram, with IMS (Integrated Magnetic Switch) Control Circuit Recommended Maximum Voltage Drop* System Voltage Starter Engagement System Type Typical Solenoid / IMS Pull-In Current (12 V

    42、) Recommended Circuit Resistance at Typical Operating Current V-drop/100 amps 12 / 24 volt Positive Shift 20A -120A 0.050 - 0.008 1.0V 12 / 24 volt Mechanical Positive Engagement 80A - 120A 0.0013 - 0.008 1.0V 12 / 24 volt Electric Soft Start Positive Engagement (w/o IMS) 150A - 350A 0.007 - 0.003 1

    43、.0V 12 / 24 volt * Electric Soft Start Positive Engagement (w/ IMS) 2A - 4A 0.500 - 0.250 N/A Resistance and voltage drop values given at 20 C (68f) Figure 10 - Table of recommended control circuit voltage drops * Most manufacturers of Soft Start type engagement systems take control of the critical

    44、control circuit voltage drop requirements via an integrated magnetic switch and associated wiring as part of the starter assembly. The OEM is only responsible for a relatively low current (2A to 4A) circuit for the integrated magnetic switch control circuit. SAE INTERNATIONAL J3053 Issued JUL2015 Pa

    45、ge 9 of 9 7. NOTES 7.1 Revision Indicator A change bar (l) located in the left margin is for the convenience of the user in locating areas where technical revisions, not editorial changes, have been made to the previous issue of this document. An (R) symbol to the left of the document title indicates a complete revision of the document, including technical revisions. Change bars and (R) are not used in original publications, nor in documents that contain editorial changes only. PREPARED BY THE SAE TRUCK AND BUS ELECTRICAL SYSTEMS COMMITTEE