    SAE J 1355-2017 Test Method for Measuring Thickness of Resilient Insulating Paddings.pdf

    • 资源ID:1026289       资源大小:102.55KB        全文页数:5页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    SAE J 1355-2017 Test Method for Measuring Thickness of Resilient Insulating Paddings.pdf

    1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there

    2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2017 SAE International All rights reserved. No part of this p

    3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497

    4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/J1355_201708 SURFACE VEHICLE RECOMMENDED PRACTICE J1355 AUG2017 Issued 1981-03 Revised 2017-08

    5、Superseding J1355 APR2010 Test Method for Measuring Thickness of Resilient Insulating Paddings RATIONALE Update contact information in Appendix A. 1. SCOPE This SAE Recommended Practice describes a laboratory test procedure for measuring the thickness of various resilient insulating padding material

    6、s that are used in the automotive industry. Such padding materials may include synthetic or non-synthetic materials, fibrous or cellular materials, high loft or compressed materials, single layer homogeneous or multilayer products, low and high surface density products. Some of these samples may be

    7、deformable and elastic, high loft thermal and acoustical fibrous materials, as well. The test method described herein has been developed to establish a means of a uniform procedure for measuring the thickness of different types of samples not only for application to all ground vehicles, but also may

    8、 be applicable to other situations or conditions. The test method is designed to measure the thickness of flat samples and not formed parts. This test method does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard

    9、 to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. This test method provides a different thickness measuring device than what has been mentioned in SAE J1355_198704. 2. REFERENCES 2.1 Applicable Documents The following public

    10、ations form a part of this specification to the extent specified herein. Unless otherwise indicated, the latest issue of SAE publications shall apply. 2.1.1 SAE Publication Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada)

    11、or +1 724-776-4970 (outside USA), www.sae.org. SAE TSB 003 Rules for SAE Use of SI (Metric) Units SAE INTERNATIONAL J1355 AUG2017 Page 2 of 5 2.1.2 ASTM Publications Available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.astm

    12、.org. ASTM D5736 Standard Test Method for Thickness of Highloft Nonwoven Fabrics 3. APPARATUS 3.1 It is a parallel plate four-bar linkage thickness measuring device with a counter weight. Appendix A at the end of this standard provides some sources from where this device can be procured. This device

    13、 is essentially a table with an upright at the rear (see Figure 1). There are four pivotal arms connected to the upright in such a way that the pivotal arms can carry a flat platen of 305 mm x 305 mm size. The pivotal arms are attached to the uprights and the platen in such a way that when the arms

    14、are raised or lowered, the platen is also raised or lowered with its faces staying parallel to the base plate at all times. The specimen (material to be measured) is placed on the table, a predetermined weight (load) is placed on the platen, and then the platen is lowered until it rests lightly on t

    15、he material. The thickness of the specimen is shown in the thickness measuring indicator. 3.2 Thickness Gauge Thickness measuring indicator with single point-contact loading foot and 0.1 mm or equivalent graduations. 3.3 Cutting Dies or Templates To cut specimens 305 mm x 305 mm in size with a toler

    16、ance not to exceed 3 mm. Figure 1 - Photograph of a typical parallel plate four-bar linkage thickness measuring device SAE INTERNATIONAL J1355 AUG2017 Page 3 of 5 4. TEST SPECIMENS 4.1 Two test specimens having the dimensions 305 mm x 305 mm shall be cut from the same lot (roll of articles), and sha

    17、ll also be free of folds, creases, or wrinkles. Avoid getting oil, water, grease, and so forth, on the test specimens when handling. 4.2 The test specimen shall be placed such that the edges of the test specimen line up evenly with the base plate (thickness measuring table) to minimize any contribut

    18、ion of edge effects. 5. CONDITIONING 5.1 After removal from the packaging, lay the sample on a flat surface for a minimum of twelve hours before cutting specimens and measuring thickness. It is recommended to condition the sample in the same environment where the measurements will be made. If the sa

    19、mple is in a compressed state and circumstances will not permit lengthy sample conditioning, the sample shall be released from compression through natural means (i.e., rising on its own accord after removal from the packaging) and allowed to recover for at least 30 minutes before cutting and testing

    20、 or as long as possible, (but more than 30 minutes), and this should be documented in the reported data. In no case, shall additional thickness recovery methods such as shaking or pulling the material be used to increase the thickness to the nominal thickness even if the natural means of recovery is

    21、 below the nominal thickness. 5.2 Tests for material classification and for arbitration purposes shall be made after the test material has been conditioned properly. Tests should be conducted at the standard conditions in the laboratory, and the temperature and the relative humidity should be docume

    22、nted and reported. 6. PROCEDURE 6.1 Perform the following steps in a controlled atmosphere per 5.2. 6.2 Place the thickness measuring device on a flat surface large enough to accommodate the device and test specimens. Handle the test specimens carefully. Insure that the thickness measuring device is

    23、 functioning according to the manufacturers recommendations. The pivot points on the platen should move smoothly and should not bind or stick. 6.3 Record in C the temperature of the testing environment, as well as the relative humidity. 6.4 Verify or set the thickness measuring indicator to zero by

    24、carefully lowering the platen before measuring the thickness of the specimens. 6.5 Raise and balance the platen to a height of 50 mm from the base plate, or to a height greater than that of the thickness of the specimen (if more than 50 mm) by carefully turning the counterweight at the rear until th

    25、e platen is balanced and at rest at this height. 6.6 Place a specimen of the material to be tested on the base plate such that when the platen is lowered its edges line up evenly with the test specimen. 6.7 Two different weights are recommended for measuring the thickness. These are 150 g weight 1 g

    26、 weight and 300 g weight 1 g weight. 6.8 Place the 150 g weight near the center of the platen and gradually lower the platen until it contacts the surface of the specimen. Release control of the weight and allow the specimen to be compressed for 10 seconds. This is also known as the loading time int

    27、erval. 6.9 Record the thickness from the thickness measuring indicator. 6.10 Rotate the specimen to its next side and follow 6.6 and 6.9 to measure and record its thickness until all sides have been measured. A total of four measurements shall be made for each specimen and arithmetically averaged to

    28、 obtain the measured thickness for that specimen. 6.11 Repeat steps 6.8, 6.9, and 6.10 using the 300 g weight. SAE INTERNATIONAL J1355 AUG2017 Page 4 of 5 6.12 If the average thickness of the specimen as measured with a 150 g and 300 g weight varies more than 10% (i.e., 1 mm variation on a 10 mm thi

    29、ck specimen) due to the difference in weight (i.e., the 150 g weight and 300 g weight), the 150 g weight shall be used and reported for the correct measurements. Otherwise, the 300 g weight shall be used and reported for the correct measurements. 6.13 Repeat the measurements on the other test specim

    30、en using the appropriate weight. Average the thickness of the two test specimens to obtain the average measured thickness of the test sample. 7. REPORT Report the following information: 7.1 Report that the thickness was determined as directed in this test method. 7.2 Description of the material or p

    31、roduct tested. 7.3 Weight applied to platen. 7.4 Condition temperature, relative humidity, and time. 7.5 Number of specimens per sample. 7.6 Average thickness. 7.7 Any modification made in accordance with this test method. 8. NOTES 8.1 Revision Indicator A change bar (l) located in the left margin i

    32、s for the convenience of the user in locating areas where technical revisions, not editorial changes, have been made to the previous issue of this document. An (R) symbol to the left of the document title indicates a complete revision of the document, including technical revisions. Change bars and (

    33、R) are not used in original publications, nor in documents that contain editorial changes only. PREPARED BY THE SAE ACOUSTICAL MATERIALS COMMITTEE SAE INTERNATIONAL J1355 AUG2017 Page 5 of 5 APPENDIX A A.1 INFORMATION ON THE THICKNESS MEASURING DEVICE This device is commonly known as Measure-Matic (also known as the Gustin-Bacon). Some possible sources of procuring the Measure-Matic device are: CertainTeed Machine Works, 101 Hatfield Road, Winter Haven, FL 33880, 800-237-7841; Fabriweld Corporation, 360 Eastpark Drive, Norwalk, OH 44857; 419-668-3358; .