欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    PPI TN-31-2010 Differences Between PEX and PB Systems for Potable Water Applications《饮用水应用中PEX系统和PB系统的差异》.pdf

    • 资源ID:1016782       资源大小:84.29KB        全文页数:4页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    PPI TN-31-2010 Differences Between PEX and PB Systems for Potable Water Applications《饮用水应用中PEX系统和PB系统的差异》.pdf

    1、 105 Decker Court Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plastipipe.org Differences Between PEX and PB Systems for Potable Water Applications TN-31/2010 . Foreword This technical note was developed and published with the technical help and financial support of the members of

    2、 the Plastics Pipe Institute. The members have shown their interest in quality products by assisting independent standard-making and user organizations in the development of standards, and also by developing reports on an industry-wide basis to help engineers, code officials, specifying groups, and

    3、users. This technical note has been prepared to provide those responsible for the maintenance of existing HDPE pipelines with suggested general guidelines for the repair of those lines that have been subjected to third party or other unforeseen damage. These guidelines constitute a set of basic oper

    4、ations that have been demonstrated by test and experience to produce satisfactory repairs with commercially available materials. Each specific procedure must be acceptable to, and qualified by, the operator having legal responsibility for the performance of the piping system. This document was not i

    5、ntended to provide system design information. Go to the PPI website at www.plasticpipe.org for different system design documents. The Plastics Pipe Institute, Inc. has prepared this technical note as a service to the industry. The information in this note is offered in good faith and believed to be

    6、accurate at the time of its preparation, but is offered without any warranty, express or implied. Additional information may be needed in some areas, especially with regard to unusual or special applications. Consult the manufacturer or material supplier for more detailed information. A list of memb

    7、er manufacturers is available from PPI. PPI does not endorse the proprietary products or processes of any manufacturer, and assumes no responsibility for compliance with applicable laws and regulations. PPI intends to revise this report from time to time, in response to comments and suggestions from

    8、 users of this note. Please send suggestions for improvements to PPI. Information on other publications can be obtained by contacting PPI directly or visiting the web site. The Plastics Pipe Institute, Inc. 469-499-1044 www.plasticpipe.org September 2010 DIFFERENCES BETWEEN PEX AND PB SYSTEMS FOR PO

    9、TABLE WATER APPLICATIONS Just as various types of metals (eg. steel, copper, iron) have different properties, various types of plastics also have different properties. Not all metal pipes perform the same, and clearly, not all plastic pipes perform the same. Thanks to modern polymer technology, cros

    10、slinked polyethylene (PEX) tubing and piping systems perform in ways that provide superior reliability and safety when compared to polybutylene (PB) piping systems used in plumbing and heating applications in Canada and USA until the mid-1990s. Crosslinked polyethylene (known as “PEX”) is a high-tem

    11、perature, pressure resistant, yet flexible, plastic (polymer) pipe. PEX tubing is approved for potable hot- and cold-water plumbing systems and hot-water (hydronic) heating systems in all model plumbing and mechanical codes across the USA and Canada. PEX tubing systems are durable, provide security

    12、of safe drinking water, and use reliable connection systems. PEX piping systems have been used for potable water applications for more than 30 years in Europe and for more than 15 years in North America. Today, the North American PEX industry is thriving in both residential and commercial constructi

    13、on. There are at least ten domestic producers of quality PEX piping and tubing systems today. The PEX industry is highly regulated. Product standards, specifications, test methods and code requirements developed over the past twenty years define tight material and production controls, require contin

    14、uous-use temperature ratings as high as 200F (93C), and mandate standardized chlorine resistance testing. Third-party certification agencies require strenuous quality control testing for PEX systems, including frequent unannounced inspections of plants and annual monitoring and re-testing. According

    15、 to product standards from organizations such as ASTM International, CSA International and NSF International, the testing requirements for PEX systems are far more stringent than for PB systems. Combining these requirements with the robust capabilities of PEX tubing and fittings, PEX systems have se

    16、veral key advantages: PEX is a crosslinked material. During production of PEX the molecules of the high-density polyethylene (HDPE) base material are permanently linked to each other by a process known as crosslinking. Crosslinking gives PEX pipes enhanced properties, such as greater long-term stabi

    17、lity against internal pressure, resistance against external damage such as scratches, and reduced creep (material flow) under compressive loads at fittings. PB piping is not crosslinked. PEX pipes are thicker than PB pipes. As required by PEX pipe standards such as ASTM F876, AWWA C-904 and CSA B137

    18、.5, PEX pipes have a wall thickness that is at least 22% thicker than the wall thickness of PB pipes. This thicker wall (SDR9 vs. SDR 11) gives better mechanical strength and resistance to damage. PEX pipes are tested to demonstrate minimum chlorine resistance. Mandatory chlorine resistance testing,

    19、 according to test method ASTM F2023, requires that all PEX tubing used for plumbing applications be tested to meet a minimum extrapolated lifetime of at least 50 years under extremely aggressive water conditions. Similar research testing using chloramines, another potable water disinfectant, indica

    20、tes that PEX is equally or even more resistant to chloramines at the same high levels and test conditions. PEX piping systems do not use polyacetal fittings. PEX piping systems use fittings that, as required by ASTM standards, are made from brass, copper, stainless steel or high-temperature polymers

    21、 engineered to be chlorine-resistant. When required, these fitting materials are tested to the same standards as PEX pipes, and must also be certified by the same third-party testing agencies. Note: Consult with each PEX pipe manufacturer for recommended fitting(s). PEX piping systems have long-term

    22、 performance requirements up to 200F (93C), whereas the highest-temperature testing required for PB was 180F (82C). Long-term hydrostatic testing required by PEX piping system standards, such as ASTM F876, AWWA C-904 and CSA B137.5, and certified to stringent requirements as established in PPI TR-3,

    23、 are used to demonstrate the following extrapolated continuous-use temperature/pressure ratings for PEX systems: 80 psi 200F 100 psi 180F 160 psi 73.4F For more information on PEX pipes and PPI hydrostatic requirements, please refer to PPI Technical Report TR-3 “Policies and Procedures for Developing HDB, PDB, SDB and MRS Ratings for Thermoplastic Materials or Pipe” and Technical Note TN-17 “Crosslinked Polyethylene (PEX) Tubing”, or visit the website at www.plasticpipe.org.


    注意事项