    PPI STATEMENT A-2013 Relative Oxidative Aggressiveness of Chloramines and Free Chlorine Disinfectants used in Treated Potable Water on Crosslinked Polyethylene (PEX) Pipe.pdf

    • 资源ID:1016757       资源大小:51.94KB       
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    PPI STATEMENT A-2013 Relative Oxidative Aggressiveness of Chloramines and Free Chlorine Disinfectants used in Treated Potable Water on Crosslinked Polyethylene (PEX) Pipe.pdf

    1、 STATEMENT A Relative Oxidative Aggressiveness of Chloramines and Free Chlorine Disinfectants used in Treated Potable Water on Crosslinked Polyethylene (PEX) Pipe Originally adopted January 2007 Revised July 9, 2013 In a research project conducted throughout 2005 and 2006 at the request of the Build

    2、ing and Construction Division (BCD) of the Plastics Pipe Institute (PPI), Jana Laboratories, an accredited laboratory, examined the relative oxidative aggressiveness of two of the most common potable water disinfectants (free chlorine and chloramines) on crosslinked polyethylene (PEX) pipes. For thi

    3、s research, samples of a commercially available PEX pipe were tested in general accordance with ASTM Standard Test Method F2023 “Standard Test Method for Evaluating the Oxidative Resistance of Crosslinked Polyethylene (PEX) Tubing and Systems to Hot Chlorinated Water”. PEX pipe samples were tested t

    4、o failure in a continuous-flow test setup designed to accelerate failure by using elevated temperatures and the highest levels of disinfectants allowed by the EPA. This projects test procedure deviated from typical ASTM F20231testing by using i) a test fluid containing chloramines, and ii) a test fl

    5、uid containing free chlorine. Both fluids had the same 4.0 parts per million (ppm) concentration throughout the test. 1ASTM F2023 is a test method for free chlorine, with water aggressiveness controlled by the minimum oxidative reduction potential or ORP. The EPA maximum limit for each of these disi

    6、nfectants is 4.0 ppm for treated potable water. For this research project, the test fluids were controlled to a pH of 6.8. Testing was conducted at elevated temperatures of 105C (221F) and 115C (239F) at 60 psig constant pressure. Testing at four (4) conditions was initiated, for a total of twenty (

    7、20) specimens of the same pipe sample. Results After the testing was completed, failure times of the PEX pipe specimens tested with the free chlorine test fluid were compared to failure times of the PEX pipe specimens tested with the chloramines test fluid. The results showed pipe failure times appr

    8、oximately 40% longer when tested with chloramines, compared to testing with free chlorine in otherwise identical test conditions. Conclusion Based on these results, it is the position of PPI BCD that chloramines are less aggressive than free chlorine to PEX pipes. Testing of oxidative resistance usi

    9、ng free chlorine, in accordance with ASTM F2023, will provide a conservative estimate of the time-to-failure for PEX pipes when used with the disinfectant chloramines. Jana Test Report, Project 04-2256 Rev. 1 is available from the PPI BCD upon request. 105 Decker Court, Suite 825, Irving, TX 75062 Phone: 469-499-1044 Fax: 469-499-1063 www.plasticpipe.org


    注意事项

    本文(PPI STATEMENT A-2013 Relative Oxidative Aggressiveness of Chloramines and Free Chlorine Disinfectants used in Treated Potable Water on Crosslinked Polyethylene (PEX) Pipe.pdf)为本站会员(explodesoak291)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!