欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    NFPA 56-2017 Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems (Effective Date 12 1 2016).pdf

    • 资源ID:1008719       资源大小:930.86KB        全文页数:59页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    NFPA 56-2017 Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems (Effective Date 12 1 2016).pdf

    1、 NFPA 56 2017 Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping SystemsIMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA STANDARDS NOTICE AND DISCLAIMER OF LIABILITY CONCERNING THE USE OF NFPA STANDARDS NFPA codes, standards, recommended practices, and gu

    2、ides (“NFPA Standards”), of which the document contained herein is one, are developed through a consensus standards development process approved by the American National Standards Institute. This process brings together volunteers representing varied viewpoints and interests to achieve consensus on

    3、re and other safety issues. While the NFPA administers the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy of any information or the soundness of any judgments contained in NFPA Standards. The NFPA di

    4、sclaims liability for any personal injury, property or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the publication, use of, or reliance on NFPA Standards. The NFPA also makes no guaranty or warranty as to the

    5、 accuracy or completeness of any information published herein. In issuing and making NFPA Standards available, the NFPA is not undertaking to render professional or other services for or on behalf of any person or entity. Nor is the NFPA undertaking to perform any duty owed by any person or entity t

    6、o someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. The NFPA has no power, nor does it undertake, to police or enforce

    7、compliance with the contents of NFPA Standards. Nor does the NFPA list, certify, test, or inspect products, designs, or installations for compliance with this document. Any certication or other statement of compliance with the requirements of this document shall not be attributable to the NFPA and i

    8、s solely the responsibility of the certier or maker of the statement. REMINDER: UPDATING OF NFPA STANDARDS Users of NFPA codes, standards, recommended practices, and guides (“NFPA Standards”) should be aware that NFPA Standards may be amended from time to time through the issuance of Tentative Inter

    9、im Amendments or corrected by Errata. An ofcial NFPA Standard at any point in time consists of the current edition of the document together with any Tentative Interim Amendment and any Errata then in effect. In order to determine whether an NFPA Standard has been amended through the issuance of Tent

    10、ative Interim Amendments or corrected by Errata, visit the “Codes email: stds_adminnfpa.org. For more information about NFPA, visit the NFPA website at www.nfpa.org. All NFPA codes and standards can be viewed at no cost at www.nfpa.org/docinfo.56-1 NFPA and National Fire Protection Association are r

    11、egistered trademarks of the National Fire Protection Association, Quincy, Massachusetts 02169. Copyright 2016 National Fire Protection Association . All Rights Reserved. NFPA 56 Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems 2017 Edition This e

    12、dition of NFPA 56, Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems, was prepared by the Technical Committee on Gas Process Safety. It was issued by the Standards Council on November 11, 2016, with an effective date of December 1, 2016, and super

    13、sedes all previous editions. This edition of NFPA 56 was approved as an American National Standard on December 1, 2016. Origin and Development of NFPA 56 In February 2010, an explosion occurred at a power plant construction site as the result of an uncontrolled release of ammable gas that was being

    14、used to clean the interior of the fuel piping system. The incident investigation resulted in urgent recommendations being issued by the U.S. Chemical Safety Board (CSB) for NFPA to develop requirements for the “safe conduct of fuel gas piping cleaning operations.” In response, the NFPA Standards Cou

    15、ncil established the Technical Committee on Gas Process Safety and tasked that committee with developing a standard to address piping system cleaning and purging operations. As a result of the CSBs urgent recommendation, NFPA issued provisional standard NFPA 56 (PS), Standard for Fire and Explosion

    16、Prevention During Cleaning and Purging of Flammable Gas Piping Systems, which prohibits the use of ammable gas as an agent for the interior cleaning of piping systems. NFPA 56 (PS) expanded on the CSB recommendations by including cleaning and purging of all ammable gas piping systems at any inlet pr

    17、essure for electric-generating plants and for industrial, commercial, and institutional applications. In addition to the use of ammable gas for cleaning and purging, the provisional standard addressed training requirements for personnel as well as notication of hazards for personnel not directly inv

    18、olved in cleaning or purging procedures. The standard required development of written procedures for cleaning and purging activities and that all such written procedures undergo a safety validation performed by a competent person. The denition of competent person was extracted directly from federal

    19、Occupational Safety and Health Administration (OSHA) regulations. NFPA 56 (PS) also adopted terminology commonly used by the petrochemical industry for those procedures: purging into service for the process of replacing air in a piping system with inert or ammable gas and purging out of service for

    20、the process of replacing ammable gas in the piping system with inert gas or air. In accordance with ANSI requirements for provisional standards, NFPA 56 (PS) was immediately submitted for revision in accordance with the NFPA Regulations Governing Committee Projects. As a result, NFPA 56 is no longer

    21、 a provisional standard and will no longer be designated with the sufx “PS.” In the 2014 edition, new requirements were added to address the use of pressure relief valves and their associated piping in purging and cleaning processes. NFPA 55, Compressed Gases and Cryogenic Fluids Code, was exempted

    22、from the scope of NFPA 56 in recognition of new requirements added to NFPA 55 to address cleaning and purging of ammable gas piping systems within the NFPA 55 scope. Also, the term source valve was dened and added to the scope because it is the term used in the compressed/industrial gas industry to

    23、demarcate the point of delivery to the piping system. The 2014 edition also included additional annex text to further clarify existing and new requirements.FIRE AND EXPLOSION PREVENTION DURING CLEANING AND PURGING OF FLAMMABLE GAS PIPING SYSTEMS 56-2 2017 Edition In the 2017 edition, the requirement

    24、s for written procedures for cleaning and purging activities have been modied to include additional topics. The procedures are now required to address nonconductive components in temporary piping assemblies in order to account for the static charge that might be induced by those components. Addition

    25、ally, the written procedures must address protection and rescue of personnel, including the selection of re-resistant clothing based on a hazard analysis in accordance with NFPA 2113, Standard on Selection, Care, Use, and Maintenance of Flame-Resistant Garments for Protection of Industrial Personnel

    26、 Against Short-Duration Thermal Exposures. New requirements have also been added to the training requirements in Chapter 5 to ensure that knowledge transfer is evident in the training program and to make sure the appropriate information is maintained in the training records.COMMITTEE PERSONNEL 56-3

    27、2017 Edition Technical Committee on Gas Process Safety Franklin R. Switzer, Jr., Chair S-afe, Inc., NY SE Hocine Ait Mohamed, Saudi Aramco, Saudi Arabia U Denise Beach, FM Global, MA I Michael W. Bethany, Eclipse/CEC Combustion Safety, Inc., OH M Leon A. Bowdoin, Jr., Consultant, MA SE Christopher S

    28、. Buehler, Exponent, Inc., NY SE Paul W. Cabot, American Gas Association, DC IM Bastiaan E. Cornelissen, Spectrum Forensics, LLC, CO SE Larry M. Danner, GE Power & Water, SC M Louis A. Donsbach, Jr., U.S. Steel Corporation, IN U Dan Dorran, Atlas Copco Rental, OR U John P. Doucette, State of CT Depa

    29、rtment of Administrative Services, CT E Rob Early, Praxair, Inc., NY M Dennis M. Kovach, American Electric Power, OH U Rep. Edison Electric Institute Kreg J. Levengood, Kiewit Power Engineers, KS SE Robert C. Naper, Energy Experts International, MA SE Rep. ANSI Gas Piping Technology Committee John R

    30、. Puskar, PuskarCo, OH SE Alan Rice, American International Group, Inc. (AIG), CT I Jerrold Sameth, Compressed Gas Association, Inc., NJ M Rep. Compressed Gas Association Bruce J. Swiecicki, National Propane Gas Association, IL IM Brett A. Wheelock, OGE/Enogex, OK M Peter J. Willse, Global Asset Pro

    31、tection Services, CT I Alternates Pat Convery, Cornerstone Energy Services, MA U (Voting Alt.) Richard A. Craig, Compressed Gas Association, VA M (Alt. to Jerrold Sameth) Scott Neil, DCP Midsteam LLC, CO M (Alt. to Brett A. Wheelock) Sam Pagadala, American International Group, Inc. (AIG), IL I (Alt.

    32、 to Alan Rice) Ali Reza, Exponent, Inc., CA SE (Alt. to Christopher S. Buehler) Gordon R. Smith, General Electric Company, NY M (Alt. to Larry M. Danner) Janna E. Shapiro, NFPA Staff Liaison This list represents the membership at the time the Committee was balloted on the nal text of this edition. S

    33、ince that time, changes in the membership may have occurred. A key to classications is found at the back of the document. NOTE: Membership on a committee shall not in and of itself constitute an endorsement of the Association or any document developed by the committee on which the member serves. Com

    34、mittee Scope: This committee shall have primary responsibility for documents on the commissioning and maintenance of ammable gas piping systems in commercial, industrial, and power plant applications, extending from the point of delivery to the equipment isolation or shutoff valve except for those already covered by the NFPA National Fuel Gas Code Technical Committee and/or the NFPA Hydrogen Technologies Technical Committee.


    注意事项

    本文(NFPA 56-2017 Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems (Effective Date 12 1 2016).pdf)为本站会员(testyield361)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开