欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    NFPA 501A-2017 Standard for Fire Safety Criteria for Manufactured Home Installations Sites and Communities (Effective Date 06 22 2016).pdf

    • 资源ID:1008675       资源大小:881.18KB        全文页数:28页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    NFPA 501A-2017 Standard for Fire Safety Criteria for Manufactured Home Installations Sites and Communities (Effective Date 06 22 2016).pdf

    1、501A NFPA Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities 2017IMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA STANDARDS NOTICE AND DISCLAIMER OF LIABILITY CONCERNING THE USE OF NFPA STANDARDS NFPA codes, standards, recommended practices, and guides (“N

    2、FPA Standards”), of which the document contained herein is one, are developed through a consensus standards development process approved by the American National Standards Institute. This process brings together volunteers representing varied viewpoints and interests to achieve consensus on re and o

    3、ther safety issues. While the NFPA administers the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy of any information or the soundness of any judgments contained in NFPA Standards. The NFPA disclaims

    4、liability for any personal injury, property or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the publication, use of, or reliance on NFPA Standards. The NFPA also makes no guaranty or warranty as to the accurac

    5、y or completeness of any information published herein. In issuing and making NFPA Standards available, the NFPA is not undertaking to render professional or other services for or on behalf of any person or entity. Nor is the NFPA undertaking to perform any duty owed by any person or entity to someon

    6、e else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. The NFPA has no power, nor does it undertake, to police or enforce complian

    7、ce with the contents of NFPA Standards. Nor does the NFPA list, certify, test, or inspect products, designs, or installations for compliance with this document. Any certication or other statement of compliance with the requirements of this document shall not be attributable to the NFPA and is solely

    8、 the responsibility of the certier or maker of the statement. REMINDER: UPDATING OF NFPA STANDARDS Users of NFPA codes, standards, recommended practices, and guides (“NFPA Standards”) should be aware that NFPA Standards may be amended from time to time through the issuance of Tentative Interim Amend

    9、ments or corrected by Errata. An ofcial NFPA Standard at any point in time consists of the current edition of the document together with any Tentative Interim Amendment and any Errata then in effect. In order to determine whether an NFPA Standard has been amended through the issuance of Tentative In

    10、terim Amendments or corrected by Errata, visit the “Codes email: stds_adminnfpa.org. For more information about NFPA, visit the NFPA website at www.nfpa.org. All NFPA codes and standards can be viewed at no cost at www.nfpa.org/docinfo.501A-1 NFPA and National Fire Protection Association are registe

    11、red trademarks of the National Fire Protection Association, Quincy, Massachusetts 02169. Copyright 2016 National Fire Protection Association . All Rights Reserved. NFPA 501A Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities 2017 Edition This edition of NFP

    12、A 501A, Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities, was prepared by the Technical Committee on Manufactured Housing. It was issued by the Standards Council on June 7, 2016, with an effective date of June 22, 2016, and supersedes all previous edition

    13、s. This edition of NFPA was approved as an American National Standard on June 22, 2016. Origin and Development of NFPA 501A NFPA activity associated with manufactured homes began in 1937, when NFPA organized its rst Committee on Trailers and Trailer Courts. The rst NFPA standard covering trailer coa

    14、ch camps appeared in 1939, with revisions in 1940, 1952, 1960, and 1964. A completely new edition was adopted in 1971, and that text was revised in 1972, 1973, 1974, 1975, 1977, and 1982. The American National Standards Institute (ANSI) approved the 1972 NFPA edition on May 8, 1973; the 1973 NFPA ed

    15、ition on December 28, 1973; the 1974 NFPA edition on January 30, 1975; the 1975 NFPA edition on February 27, 1976; and the 1977 NFPA edition on October 18, 1977. The 1982 edition of Standard for Firesafety Criteria for Mobile Home Installations, Sites, and Communities superseded the 1977 edition and

    16、 was adopted by NFPA at its Annual Meeting held in San Francisco in 1982. The 1982 edition was produced by the newly formed Committee for Firesafety for Mobile Homes (created June 1979), which was charged with the responsibility of developing documents for re safety criteria for single-family mobile

    17、 homes, including the installation, sites, and communities, and the maintenance of and improvements for existing mobile homes. Therefore, the 1982 edition excluded all sections of previous editions not considered within the committee scope. Notably excluded were stabilizing and anchoring systems, re

    18、quirements for piers and footings, and plumbing, including sewage disposal systems. Requirements for park electrical systems were addressed by reference to NFPA 70, National Electrical Code. Modications were also made in sections dealing with fuel supply, air conditioning, and life and re safety. Ma

    19、jor revisions to the standard were made in the 1987 edition in an attempt to better coordinate the NFPA chapters in a joint publication with the National Conference of States on Building Codes and Standards (NCSBCS), ANSI A225.1/NFPA 501A. Major changes included substituting manufactured home for mo

    20、bile home throughout; deleting Chapter 3, Air Conditioning; expanding Chapter 2, Fuel Supply; and combining three appendixes into two. The standard was reconrmed in 1992 with a plan to expand the scope of NFPA 501A to cover re safety requirements for the design, construction, installation, alteratio

    21、n/rehabilitation, maintenance, use, and occupancy of manufactured homes, manufactured home sites, and manufactured home communities, including accessory buildings and structures. This was a major revision of the scope and the entire standard, and the committee targeted a complete revision of NFPA 50

    22、1A for 1994. The 1997 edition was a reconrmation of the 1992 edition of NFPA 501A. The proposed expansion of the scope of the 1992 edition, as noted in the preceding paragraph, was discussed and acted on by the technical committee. The scope of NFPA 501A was not expanded; instead, a new document, NF

    23、PA 501, Standard on Manufactured Housing, was generated. NFPA 501 represented the reconstituted 1977 edition of NFPA 501B, Standard for Mobile Homes, which was the basis for the federal Manufactured Home Construction and Safety Standards.FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITE

    24、S, AND COMMUNITIES 501A-2 2017 Edition The earlier editions of NFPA 501A were jointly developed and published by NFPA and NCSBCS as A225.1/NFPA 501A. The 1997 edition of NFPA 501A was published as a separate, stand-alone document in agreement with NCSBCS and contained only the re safety requirements

    25、. The nonre safety requirements were published by NCSBCS as A225.1 (1994 edition). NFPA assumed responsibility for NCSBCS A225 standard in 2003, which was processed concurrently with the 2003 edition of NFPA 501A. The 1999 edition was a reconrmation of the 1997 edition. In June 1998, NFPA was select

    26、ed by the U.S. Department of Housing and Urban Development (HUD) to update the federal standards (24 CFR 3280) for manufactured homes. As a result of this selection by HUD, the original technical committee for manufactured homes was expanded into six technical committees and a technical correlating

    27、committee. The expansion occurred during the Report on Comments phase of the 1999 edition. The 2000 edition had only a few minor revisions. One revision, in 4.3.5, pertained to updating the water supplies for re department operations. The other revisions were editorial in nature. The 2003 edition wa

    28、s reformatted to meet the editorial and format-related requirements of the Manual of Style for NFPA Technical Committee Documents. Several denitions were deleted during that revision cycle. The 2005 edition incorporated new requirements for re separation distances between manufactured homes. The 200

    29、9 edition of NFPA 501A updated extracted text where appropriate. In addition, revisions were made that claried requirements and added new ones for water supplies that serve the site, and newly revised criteria were introduced for re department access roads and paths. The 2013 edition was revised to

    30、include requirements on retroactivity and equivalencies in Chapter 1. Provisions for storm shelters, community buildings, and emergency considerations such as windstorms were added. Several modications were made to the organization of requirements within the document. The 2017 edition includes the f

    31、ollowing revisions: (1) The last two sentences of 7.1.4 have been removed referencing the guidance document is sufcient without getting into the details of the document itself. (2) Because Annex C in previous editions did not address recommendations for residential re sprinkler systems in a manner similar to what is currently provided for home smoke alarms, language has been added to address maintenance and testing of NFPA 13D systems by directing the owner to the practices recommended in NFPA 13D. (3) References have been appropriately updated.


    注意事项

    本文(NFPA 501A-2017 Standard for Fire Safety Criteria for Manufactured Home Installations Sites and Communities (Effective Date 06 22 2016).pdf)为本站会员(livefirmly316)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开