欢迎来到麦多课文档分享! | 帮助中心 海量文档,免费浏览,给你所需,享你所想!
麦多课文档分享
全部分类
  • 标准规范>
  • 教学课件>
  • 考试资料>
  • 办公文档>
  • 学术论文>
  • 行业资料>
  • 易语言源码>
  • ImageVerifierCode 换一换
    首页 麦多课文档分享 > 资源分类 > PDF文档下载
    分享到微信 分享到微博 分享到QQ空间

    NFPA 1906 AMD 3-2017 Standard for Wildland Fire Apparatus (Effective Date 9 6 2017).pdf

    • 资源ID:1008377       资源大小:46.43KB        全文页数:5页
    • 资源格式: PDF        下载积分:10000积分
    快捷下载 游客一键下载
    账号登录下载
    微信登录下载
    二维码
    微信扫一扫登录
    下载资源需要10000积分(如需开发票,请勿充值!)
    邮箱/手机:
    温馨提示:
    如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
    如需开发票,请勿充值!如填写123,账号就是123,密码也是123。
    支付方式: 支付宝扫码支付    微信扫码支付   
    验证码:   换一换

    加入VIP,交流精品资源
     
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    NFPA 1906 AMD 3-2017 Standard for Wildland Fire Apparatus (Effective Date 9 6 2017).pdf

    1、 Tentative Interim Amendment NFPA1906 Standard for Wildland Fire Apparatus 2016 Edition Reference: 2.3.8, 14.1.1, 14.4, A.14.4, A.14.4.3.4, A.14.1.1(new), and E.1.2.4 TIA 16-3 (SC 17-8-29 / TIA Log #1267) Pursuant to Section 5 of the NFPA Regulations Governing the Development of NFPA Standards, the

    2、National Fire Protection Association has issued the following Tentative Interim Amendment to NFPA 1906, Standard for Wildland Fire Apparatus, 2016 edition. The TIA was processed by the Technical Committee on Fire Department Apparatus, and was issued by the Standards Council on August 15, 2017, with

    3、an effective date of September 4, 2017. A Tentative Interim Amendment is tentative because it has not been processed through the entire standards-making procedures. It is interim because it is effective only between editions of the standard. A TIA automatically becomes a public input of the proponen

    4、t for the next edition of the standard; as such, it then is subject to all of the procedures of the standards-making process. 1. Delete an entry in 2.3.8 to read as follows: 2.3.8 SAE Publications. Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096-0001 SAE J1194, Rollover

    5、 Protective Structures (ROPS) for Wheeled Agriculture Tractors, 2009. 2. Revise 14.1.1 to read as follows: 14.1.1* Each crew riding position shall be within a fully enclosed personnel area except as provided in Section 14.4. 3. Delete section 14.4 through 14.4.3.6 and associated Annexes A.14.4* and

    6、A.14.4.3.4 as shown: 14.4* On-Board Pump-and-Roll Fire- Fighting Position. 14.4.1 If an on-board pump-and-roll fire fighting position as described in this section is provided it shall be on a wildland fire apparatus with a GVWR of no more than 19,500 lbs. 14.4.2 If an on-board pump-and-roll fire fig

    7、hting position is provided, it shall include the following: (1) A seat with an approved Type 1 seat belt for each fire- fighting position (2) Controls required by the operator within reach without removing the seat belt (3) A means of communication with the driver (4) One safety sign warning of the

    8、hazards of this riding position that is substantially similar to FAMA44, which warns of riding safety procedures, and the maximum speed of 10 mph visible from the pump-and-roll fire-fighting position (5) Safety sign FAMA45, which warns of driving safety procedures, and the maximum speed of 10 mph vi

    9、sible from the drivers position or visible to the driver while entering the cab 14.4.3 If the seating position is located outside the cab, it shall meet requirements in 14.4.3.1 through 14.4.3.6. 14.4.3.1 The seating position shall be located behind the cab and ahead of the rear axle. 14.4.3.2 A pro

    10、tective structure shall be provided in compliance with the side impact and crush criteria from SAE J1194,Rollover Protective Structures (ROPS) for Wheeled Agricultural Tractors. 14.4.3.3 The protective structure shall be designed to allow exit out of either side of the vehicle. 14.4.3.4* The protect

    11、ive structure shall include a perforated plate or mesh with openings no larger than 1.5 in. (3.8 cm) 1.5 in. (3.8 cm) or other solid guard to protect from brush hazards at the front, the back, and the roof. 14.4.3.5 A door or gate with a latching mechanism shall be provided on each side of the vehic

    12、le designed to allow exit out of either side of the vehicle. 14.4.3.5.1 The door or gate shall be designed to prevent outward swing even in the event of failure of the latching mechanism. 14.4.3.5.2 The door or gate shall be at least 48 in. (1200 mm) high from the walking surface below the firefight

    13、ers feet. 14.4.3.5.3 The door or gate shall be constructed so there are no horizontal or vertical openings below the 48 in. (1200 mm) minimum height greater than 24 in. (610 mm) in either direction. 14.4.3.6 Equipment located within the seating enclosure position protective structure shall meet the

    14、requirements of 14.1.10 A.14.4 Typically, while engaged in fire-fighting operations on structural fires, apparatus are positioned in a safe location, and hose is extended as necessary to discharge water or suppressants on the combustible material. In wildland fire suppression, mobile attack is often

    15、 utilized in addition to stationary pumping. In mobile attack, sometimes referred to as pump-and-roll, water is discharged from the apparatus while the vehicle is in motion. Pump-and-roll operations are inherently more dangerous than stationary pumping because the apparatus and personnel are in clos

    16、e proximity to the fire combined with the additional exposure to hazards caused by a vehicle in motion. The personnel and/or apparatus could be subject to injury or damage due to accidental impact, rollover, and/or environmental hazards, including burn over. To mitigate the increased risk inherent w

    17、ith pump-and-roll operations, the following tactics are recommended: (1) Driver is located inside the apparatus in a seated, belted position within the enclosed cab. Fire fighter(s) located outside the cab, walking alongside the apparatus, in clear view of the driver, discharging water with a short

    18、hose line. (2) Driver and fire fighter(s) are located inside the apparatus in a seated, belted position within the enclosed cab. Water is discharged via a monitor or turret that is controlled from within the apparatus. (3) Driver is located inside the apparatus in a seated, belted position within th

    19、e enclosed cab with one or more fire fighters seated and belted in the on-board pump-and-roll fire-fighting position as specified in Section 14.4. (4) Driver and fire fighter(s) are located inside the apparatus in a seated, belted position within the enclosed cab, but water is discharged with a shor

    20、t hose line or hard line out an open cab window. (5) And under no circumstances is it ever considered safe practice to ride standing or seated on the exterior of the apparatus for mobile attack other than seated and belted in an on-board pump-and-roll fire-fighting position. (See Section 6.3 of NFPA

    21、 1500.) The on-board pump-and-roll fire-fighting position should only be used when the following conditions are met: (1) The apparatus is actively engaged in mobile attack on the fire line. (2) The fuel model is characterized as fine fuels. (3) The ground is level, flat, and free of obstacles. (4) D

    22、river visibility is unobstructed. (5) Vehicle speeds are no greater than 10 mph. (6) Fire fighter is wearing full protective NFPA 1977-compliant personal protective equipment and is equipped with a fire shelter. A.14.4.3.4 This is to protect against objects such as limbs entering the seating enclosu

    23、re. Woven wire cloth with in. (0.6 cm) diameter wire spaced at 1 in. (4.4 cm) on centers is commonly used in the forestry industry to provide this protection. 4. Add new A.14.1.1 to read as follows: A.14.1.1 Typically, while engaged in fire-fighting operations on structural fires, apparatus are posi

    24、tioned in a safe location, and hose is extended as necessary to discharge water or suppressants on the combustible material. In wildland fire suppression, mobile attack is often utilized in addition to stationary pumping. In mobile attack, sometimes referred to as “pump-and-roll,” water is discharge

    25、d from the apparatus while the vehicle is in motion. Pump-and-roll operations are inherently more dangerous than stationary pumping because the apparatus and personnel are in close proximity to the fire combined with the additional exposure to hazards caused by a vehicle in motion, often on uneven g

    26、round. The personnel and/or apparatus could thus be more easily subject to injury or damage due to accidental impact, rollover, and/or environmental hazards, including burn over. To potentially mitigate against the increased risk inherent with pump-and-roll operations, the following alternatives are

    27、 provided for consideration: (1) Driver and fire fighter(s) are located inside the apparatus in a seated, belted position within the enclosed cab. Water is discharged via a monitor or turret that is controlled from within the apparatus. (2) Driver and fire fighter(s) are located inside the apparatus

    28、 in a seated, belted position within the enclosed cab, but water is discharged with a short hose line or hard line out an open cab window. (3) Driver is located inside the apparatus in a seated, belted position within the enclosed cab with one or more fire fighters seated and belted in the on-board

    29、pump-and-roll fire-fighting position as described in a following section. (4) Driver is located inside the apparatus in a seated, belted position within the enclosed cab. Fire fighter(s) is located outside the cab, walking alongside the apparatus, in clear view of the driver, discharging water with

    30、a short hose line. Under no circumstances is it ever considered a safe practice to ride standing or seated on the exterior of the apparatus for mobile attack other than seated and belted in an on-board pump-and-roll fire-fighting position. The on-board pump-and-roll fire-fighting position should onl

    31、y be used when the following conditions are met: (1) The apparatus is actively engaged in mobile attack on the fire line (2) The fuel model is characterized as fine fuels (3) The ground is level, flat, and free of obstacles (4) Driver visibility is unobstructed (5) Vehicle speeds are no greater than

    32、 10 mph and (6) Fire fighter is wearing full protective NFPA 1977-compliant personal protective equipment and is equipped with a fire shelter On-Board Pump-and-Roll Fire-Fighting Position. If an on-board pump-and-roll fire-fighting position as described as follows is provided, it should only be on a

    33、 wildland fire apparatus with a GVWR of no more than 19,500 lb. If an on-board pump-and-roll fire-fighting position is provided, it should, at minimum, include the following safety-related attributes: (1) A seat with an approved Type 1 seat belt for each fire- fighting position (2) Controls required

    34、 by the operator within reach without removing the seat belt (3) A means of communication with the driver (4) One safety sign warning of the hazards of this riding position that is substantially similar to FAMA44, which warns of riding safety procedures, and the maximum speed of 10 mph visible from

    35、the pump-and-roll fire-fighting position and (5) Safety sign FAMA45, which warns of driving safety procedures, and the maximum speed of 10 mph visible from the drivers position or visible to the driver while entering the cab If the seating position is located outside the cab, it should also meet the

    36、 following requirements: (1) The seating position should be located behind the cab and ahead of the rear axle (2) A protective structure should be provided in compliance with the side impact and crush criteria from SAE J1194, Rollover Protective Structures (ROPS) for Wheeled Agricultural Tractors (3

    37、) The protective structure should be designed to allow exit from either side of the vehicle (4) The protective structure should include a perforated plate or mesh with openings no larger than 1.5 in. (3.8 cm) 1.5 in. (3.8 cm) or other solid guard to protect from brush hazards at the front, the back,

    38、 and the roof. This is to protect against objects such as limbs entering the seating enclosure. Woven wire cloth with in. (0.6 cm) diameter wire spaced at 1 in. (4.4 cm) on centers is commonly used in the forestry industry to provide this protection and (5) A door or gate with a latching mechanism s

    39、hould be provided on each side of the vehicle designed to allow exit out of either side of the vehicle. a. The door or gate should be designed to prevent outward swing even in the event of failure of the latching mechanism b. The door or gate should be at least 48 in. (1200 mm) high from the walking

    40、 surface below the fire-fighters feet and c. The door or gate should be constructed so there are no horizontal or vertical openings below the 48 in. (1200 mm) minimum height greater than 24 in. (610 mm) in either direction. Equipment located within the seating enclosure position protective structure

    41、 should meet the requirements of 14.1.10. Development of this Design. Fire-fighting is an inherently dangerous operation. This is especially true of fighting a moving wildland fire in fine fuels. There are many techniques used and a great deal of discussion about the safest way to fight these fires.

    42、 Over the years, many fire companies and apparatus manufacturers have developed techniques and equipment for fighting wildland fine-fuel fires. These have included fighting fire from seats mounted to front bumpers, sitting on hoods or hose reels, standing on flat beds, standing in step wells on the

    43、side of apparatus, standing on running boards, or walking alongside a moving apparatus. All of these approaches are extremely dangerous. The Fire Department Apparatus Committee did extensive work to try to come up with a safer solution. We looked at the available apparatus and techniques that have b

    44、een historically used in the industry. The preceding suggestions are safer than any of these ad-hoc techniques. The Fire Service Occupational Safety and Health Committee (NFPA 1500) does not approve of any fireground operations that permit the fire-fighter to ride outside the fully enclosed cab of a

    45、 moving apparatus. 5. Add new entry to E.1.2.4 to read as follows: E.1.2.4 SAE Publications. Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096-0001 SAE J1194, Rollover Protective Structures (ROPS) for Wheeled Agriculture Tractors, 2016. Issue Date: August 17, 2017 Effective Date: September 6, 2017 (Note: For further information on NFPA Codes and Standards, please see www.nfpa.org/docinfo) Copyright 2017 All Rights Reserved NATIONAL FIRE PROTECTION ASSOCIATION


    注意事项

    本文(NFPA 1906 AMD 3-2017 Standard for Wildland Fire Apparatus (Effective Date 9 6 2017).pdf)为本站会员(bowdiet140)主动上传,麦多课文档分享仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文档分享(点击联系客服),我们立即给予删除!




    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1 

    收起
    展开